82 resultados para mean pressure gradient.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The effects of adrenergic stimulation on mean circulatory filling pressure (MCFP), central venous pressure (P-CV) and stroke volume (Vs), as well as the effects of altered MCFP through changes of blood volume were investigated in rattlesnakes (Crotalus durissus). MCFP is an estimate of the upstream pressure driving blood towards the heart and is determined by blood volume and the activity of the smooth muscle cells in the veins (venous tone). MCFP can be determined as the plateau in P-CV during a total occlusion of blood flow from the heart.Vs decreased significantly when MCFP was lowered by reducing blood volume in anaesthetised snakes, whereas increased MCFP through infusion of blood (up to 3 ml kg(-1)) only led to a small rise in Vs. Thus, it seems that end-diastolic volume is not affected by an elevated MCFP in rattlesnakes. To investigate adrenergic regulation on venous tone, adrenaline as well as phenylephrine and isoproterenol (alpha- and beta-adrenergic agonists, respectively) were infused as bolus injections (2 and 10 mu g kg(-1)). Adrenaline and phenylephrine caused large increases in MCFP and P-CV, whereas isoproterenol decreased both parameters. This was also the case in fully recovered snakes. Therefore, adrenaline affects venous tone through both alpha- and beta-adrenergic receptors, but the alpha-adrenergic receptor dominates at the dosages used in the present study. Injection of the nitric oxide donor SNP caused a significant decrease in P-CV and MCFP. Thus, nitric oxide seems to affect venous tone.
Resumo:
Introduction. Brain arginine(8)-vasopressin (AVP), through the V-1a- and V-2-receptors, is essential for the maintenance of mean arterial pressure (MAP). Central AVP interacts with the components of the renin-angiotensin system, which participate in MAP regulation. This study all to determine the effects of V-1a-, V-2- and V-1a/V-2-AVP selective antagonists and AT(1)- and AT(2)-angiotensin II (Ang II) selective antagonists on the MAP induced by AVP injected into the medial septal area (MSA) of the brain.Materials and methods. Male Holtzman rats with stainless steel cannulae implanted into the MSA were used in experiments. Direct MAP was recorded in Conscious rats.Results. AVP administration into the MSA caused a prompt and potent pressor response in a dose-dependent fashion. Pretreatment with the V-1a- and V-2-antagonists reduced, whereas prior injection of the V-1a/V-2-antagonist induced a decrease in the MAP that remained below the baseline. Both AT(1)- and AT(2)-antagonists elicited a decrease, While simultaneous injections of two antagonists were more effective in decreasing the MAP induced AVP.Conclusion. These results indicate there is a synergism bell the V-1a- and V-2-AVP, and AT(1)- AT, and AT(2)-Ang II receptors in the MSA in the regulation of MAP.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The influence of 2 different levels of the inspired oxygen fraction (FiO(2)) on blood gas variables was evaluated in dogs with high intracranial pressure (ICP) during propofol anesthesia (induction followed by a continuous rate infusion [CRI] of 0.6 mg/kg/min) and intermittent positive pressure ventilation (IPPV). Eight adult mongrel dogs were anesthetized on 2 occasions, 21 d apart, and received oxygen at an FiO(2) of 1.0 (G100) or 0.6 (G60) in a randomized crossover fashion. A fiberoptic catheter was implanted on the surface of the right cerebral cortex for assessment of the ICP. An increase in the ICP was induced by temporary ligation of the jugular vein 50 min after induction of anesthesia and immediately after baseline measurement of the ICP. Blood gas measurements were taken 20 min later and then at 15-min intervals for 1 h. Numerical data were submitted to Morrison's multivariate statistical methods. The ICP, the cerebral perfusion pressure and the mean arterial pressure did not differ significantly between FiO(2) levels or measurement times after jugular ligation. The only blood gas values that differed significantly (P < 0.05) were the arterial oxygen partial pressure, which was greater with G100 than with G60 throughout the procedure, and the venous haemoglobin saturation, that was greater with G100 than with G60 at M0. There were no significant differences between FiO(2) levels or measurement times in the following blood gas variables: arterial carbon dioxide partial pressure, arterial hemoglobin saturation, base deficit, bicarbonate concentration, pH, venous oxygen partial pressure, venous carbon dioxide partial pressure and the arterial-to-end-tidal carbon dioxide difference.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study analyzed the accuracy/agreement of the Omron MX3 monitor on 165 adolescents. Blood pressure was measured by the automatic monitor connected in Y with the mercury column (three consecutive and simultaneous measures). The independent measures were analyzed, and the mean differences between systolic and diastolic measures for both methods were calculated and compared with British Hypertension Society (BHS) and Association for the Advancement of Medical Instrumentation (AAMI) criteria. The automatic monitor received the highest degree of BHS recommendations for systolic and diastolic blood pressures according to the BHS. The median (25th and 75th) difference between the observer and the monitor measurements was -2 (-6 and 1) mmHg for systolic and 0 (-3 and1) mmHg for diastolic pressures. The monitor also satisfies the AAMI standard for the studied population. In conclusion, the Omron MX3 Plus monitor can be considered reliable and valid for clinical practice and is in accordance with BHS and AAMI criteria.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The gastrointestinal tract is one of the first organs affected by hypoperfusion during hemorrhagic shock. The hemodynamics and oxygen transport variables during hemorrhagic shock and resuscitation can be affected by the anesthetics used. In a model of pressure-guided hemorrhagic shock in dogs, we studied the effects of three halogenated anesthetics - halothane, sevoflurane, and isoflurane - at equipotent concentrations on gastric oxygenation. Thirty dogs were anesthetized with 1.0 minimum alveolar anesthetic concentration (MAC) of either halothane, sevoflurane, or isoflurane. A gastric tonometer was placed in the stomach to determine mucosal gastric CO2 (PgCO(2)) and for the calculation of gastric-arterial PCO2 gradient (PCO2 gap). The dogs were splenectomized and hemorrhaged to hold mean arterial pressure at 40-50 mm Hg over 45 min and then resuscitated with the shed blood volume. Hemodynamics, systemic oxygenation, and PCO2 gap were measured at baseline, after 45 min of hemorrhage, and at 15 and 60 min after blood resuscitation. Hemorrhage induced reductions of mean arterial pressure and cardiac index, while systemic oxygen extraction increased (p < .05), without significant differences among groups (p > .05). Halothane group showed significant lower PCO2 gap values than the other groups (p < .05). After 60 min of shed blood replacement, all groups restored hemodynamics, systemic oxygenation, and PCO2 gap to the prehemorrhage levels (p > .05), without significant differences among groups (p > .05). We conclude that halothane is superior to preserve the gastric mucosal perfusion in comparison to isoflurane and sevoflurane, in dogs submitted to pressure-guided hemorrhagic shock at equipotent doses of halogenated anesthetics.
Resumo:
Objective: To evaluate the systemic blood pressure (BP) during daytime and nighttime in children with sleep breathing disorders (SBD) and compare parameters of BP in children with diagnosis of obstructive sleep apnea syndrome (OSA) to those one with primary snoring (PS).Methods: Children, both genders, aged from 8 to 12 years, with symptoms of SBD realized an overnight polysomnography followed by a 24 h recording of ambulatory BP.Results: All subjects presented with a history of snoring 7 nights per week. Children who have apnea/hipoapnea index >= four or a apnea index >= one presented a mean BP of 93 +/- 7 mmHg and 85 +/- 9 mmHg diurnal and nocturnal respectively whereas children who have a apnea/hipoapnea < four or a apnea index < one presented 90 +/- 7 mmHg and 77 +/- 2 mmHg. Eight children out of fourteen, from OSA group, lost the physiologic nocturnal dipping of the blood pressure. Among OSA children 57% were considered non-dippers. Two (16%) have presented absence of nocturnal dipping among children with primary snoring. The possibility of OSA children loosing physiologic blood pressure dipping was 6.66 higher than the possibilities of patients from PS group.Discussion: Our results indicate that children with sleep apnea syndrome exhibit a higher 24 h blood pressure when compared with those of primary snoring in form of decreased degree of nocturnal dipping and increased levels of diastolic and mean blood pressure, according to previous studies in literature. OSA in children seems to be associated to the development of hypertension or other cardiovascular disease. (C) 2012 Elsevier B.V. All rights reserved.