40 resultados para maximum angular velocity


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O objetivo deste estudo foi comparar a taxa de desenvolvimento de força (TDF) nas contrações isométrica e isocinética concêntrica a 60°.s-1 e 180°.s-1. Quatorze indivíduos do gênero masculino (idade = 23,1 ± 2,8 anos; estatura = 174 ± 31,3cm; massa corporal = 81 ± 12kg) realizaram inicialmente uma familiarização ao equipamento isocinético. Posteriormente, os indivíduos realizaram em ordem randômica cinco contrações isocinéticas máximas para os extensores do joelho a 60°.s-1 e 180°.s-1 para determinar o torque máximo concêntrico (TMC) e duas contrações isométricas máximas de 3s para determinar o torque máximo isométrico (TMI). O TMI (301,4 ± 56,0N.m) foi maior do que o TMC a 60°.s-1 (239,8 ± 42,2N.m) e 180°.s-1 (175,0 ± 32,5 N.m). O TMC a 60°.s-1 foi maior do que o TMC a 180°.s-1. Para os intervalos de 0-30ms e 0-50ms, a TDF na condição isométrica (1.196,6 ± 464,6 e 1.326,5 ± 514,2N.m.s-1, respectivamente) foi similar à TDF a 60°.s-1 (1.035,4 ± 446,2 e 1.134,3 ± 448,4N.m.s-1) e maior do que a 180°.s-1 (656,7 ± 246,6 e 475,2 ± 197,9N.m.s-1), sendo ainda que a TDF na contração concêntrica a 180°.s-1 foi menor do que a 60°.s-1. No intervalo de 0-100ms, a TDF da contração isométrica (1.248,8 ± 417,4N.m.s-1) foi maior que a obtida na contração isocinética rápida (909,2 ± 283,4N.m.s-1). A TDF obtida na contração isocinética lenta (1.005,4 ± 247,7N.m.s-1) foi similar à obtida na contração isométrica e na concêntrica isocinética rápida. No intervalo 0-150ms, a TDF isométrica (1.084,2 ± 332,1N.m.s-1) foi maior do que as concêntricas (60°.s-1 e 180°.s-1) (834,8 ± 184,2 e 767,6 ± 201,8N.m.s-1, respectivamente), não existindo diferenças entre estas duas últimas. Conclui-se que a TDF é dependente do tipo e da velocidade de contração, suportando a hipótese de que maiores velocidades de contração acarretam maior inibição do drive neural no início do movimento.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Silica sonogels with different porosities were prepared by acid sono-hydrolysis of tetraethoxysilane. Wet sonogels were studied using small-angle x-ray scattering (SAXS) and differential scanning calorimetry (DSC). The DSC shows a broad thermal peak below the normal water melting point associated with the melting of confined ice nanocrystals, or nanoporosity. The nanopore size distribution was determined from the Gibbs-Thomson equation. As the porosity is increased, a second sharp DSC thermal peak with onset temperature at the water melting point is apparent, which was associated with the melting of ice macrocrystals, or macroporosity. The DSC result could be causing misinterpretation of the macroporosity because water may not be exactly confined in very feeble silica network regions in sonogels with high porosity. The structure of the wet gels can be described fairly well as mutually self-similar mass fractal structures with characteristic length. increasing from similar to 1.8 to similar to 5.4 nm and mass fractal dimension D diminishing discretely from similar to 2.6 to similar to 2.3 as the porosity increases in the range studied. More specifically, such a structure could be described using a two-parameter correlation function gamma(r) similar to r(D-3) exp(-r/xi), which is limited at larger scale by the cut-off distance xi but without a well-defined small scale cut-off distance, at least up to the maximum angular domain probed using SAXS in the present study.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Com a finalidade de quantificar o desempenho dos sistemas de debulhamento e limpeza da colhedora Penha CLM-350,, estudou-se as perdas percentuais era grão de milho, ocorridos na saída de palhas, bem como a porcentagem de impurezas, presente no milho ensacado. Tomando-se como 100% os grãos de milho colhidos pelo sistema espigador, determinou-se o valor percentual perdido pelos sistemas de debulhamento e limpeza, bem como a porcentagem de impurezas presente nos grãos de milho ensacado, nos diversos tratamentos estudados. O teor médio de umidade foi de 15,78% (b.u.). Os tratamentos correspondentes ao sistema de debulhamento e limpeza são as velocidades periféricas do debulhador ou as rotações do aspirador em faces da configuração geométrica da máquina. Os resultados obtidos foram estudados através da análise de variância, empregando-se os testes F, aos níveis de 1% e 5% de probabilidade e o teste Tukey, para a comparação estatística entre as médias. A análise estatística para verificar a influência da rotação do aspirador, era relação a porcentagem de grãos de milho perdidos na saída de palhas, mostrou diferenças altamente significativas, podendo-se admitir uma relação direta entre os dois parâmetros nas condições do ensaio. Com relação a rotação do aspirador e a porcentagem de impurezas, presentes nos grãos de milho ensacados, os testes das médias revelaram significância entre os tratamento D (1241,7 rpm) e E (820 rpm) sendo que este último apresentou a maior média. Uma análise mais acurada dos resultados sugere que a porcentagem de impurezas, estaria mais na dependência das relações de fluxo através da colhedora, do que propriamente do regime do aspirador.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cm vistas a estudar o efeito do sistema de debulhamento na qualidade dos grãos de milho, realizou-se o presente trabalho, onde foram estudados os danos mecânicos sofridos pelos grãos, bem como os danos mecânicos invisíveis, evidenciados pelos testes de germinação. Nos diversos tratamentos estudados, determinou-se a porcentagem de umidade presente nos grãos de milho. Definiu-se a velocidade periférica do debulhador, pelo diâmetro (300 mm) do mesmo e as rotações, para os diversos tratamentos. O delineamento experimental foi de blocos ao acaso com 5 tratamentos e 6 repetições onde foram estudados os valores percentuais de grãos inteiros e quebrados, os teores de umidade correspondentes e os valores de germinação através da análise de variância. Empregou-se o teste F aos níveis de 1% e 5% de probabilidade e o teste Tukey para comparação entre as médias. da análise pode-se concluir que em relação ao teor de umidade dos grãos, os tratamentos não diferiram estatisticamente.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this study was to examine the effects of high intensity exhaustive running exercise on the muscular torque capacity of the knee extensors for two types of contraction (concentric and eccentric) at different angular velocities (60 and 180 degrees/s) in well-trained runners. Eleven male runners specialized in middle and long-distance running volunteered to participate in this study. Initially each subject performed, on different days, two familiarization sessions on an isokinetic dynamometer and an incremental treadmill test to volitional exhaustion to determine the velocity associated with the onset of blood lactate accumulation (OBLA). The subjects then returned to the laboratory on two occasions, separated by at least seven days, to perform maximal isokinetic knee contractions at each of the velocities under eccentric (Ecc) and concentric (Con) conditions. Conducted randomly, one test was performed after a standardized warm-up period of 5 min at 50% VO2 max. The other test was performed 15 min after continuous running at OBLA until volitional exhaustion. Following this high intensity exercise there was a significant reduction of Con at 60 degrees/s and a significant reduction of Ecc at both velocities. Percent strength losses after running exercise were significantly different between contraction types only at 180 degrees/s. We can conclude that the reduction in isokinetic peak torque of the knee extensors after a session of high intensity exhaustive running exercise at OBLA depends on the contraction type and angular velocity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We describe an experimental set-up for studying and determining the centripetal force acting on a body whose mass and radius of circular trajectory are known. The experimental behaviour is determined and compared with theoretical predictions by using a system that allows for the evaluation of the angular velocity by means of electric current measurements, and by assuming a potential dependence of the force on the body mass, radius and angular velocity. © 2007 IOP Publishing Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To analyze the effect of running intensity on stride length (SL), stride frequency (SF), stride time (ST) and the electromyographic signal of the rectus femoris (RF), vastus lateralis (VL), vastus medialis (VM), tibialis anterior (TA), biceps femoris (BF) and gastrocnemius lateralis (GL) muscles. Methods: Nine well-trained runners performed an incremental protocol with an initial velocity of 10km.h-1, and increments of 1km.h-1 every 3minutes until exhaustion. The electromyographic activity, SL, SF, ST, inter-stride coefficient of variation, and association between kinematic and electromyographic parameters were calculated at 60%, 80% and 100% of maximum running velocity. Results: SL, SF and electromyographic activity of the RF, VM, VL and GL increased and the ST decreased with increased running speed. Electromyographic variability of VL and VM was higher than GL, and variability was lower in TA than all other muscles. The inter-stride variability of muscle activation was associated with kinematic parameters, and their variability, differently as running speed increased. Conclusion: The incremental protocol increased electromyographic activity differently among lower limb muscles; increased SF and SL, and decreased ST, without changing the variability of these variables. Muscle activation variability was correlated with kinematic parameters, but the relationships among these measures varied with running intensity. © 2013 .

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Ciências Biológicas (Biologia Vegetal) - IBRC

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Física - IFT

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this study was to investigate the influence of previous active static stretch on the peak torque (PT) and rate of force development (TDF) during isokinetic concentric contractions at 60 and 180.s-1 in active individuals. Twelve active subjects with ages between 18 and 30 years participated of this study. The individuals were submitted in different days to the following tests: 1) Familiarization session to the isokinetic dynamometer; 2) Five maximal isokinetic concentric contractions for knee extensors at each angular velocity (60 and 180.s-1) to determine PT and TDF (Control), and; 3) Two active static stretching exercises for the dominant leg extensors (10 x 30 s for each exercise, with 20 s of rest). After the stretching, the isokinetic test was repeated (Post-Stretching). The conditions 2 and 3 were performed in random order. There was no significant modification after the stretch exercises on the PT, angle and time at which the PT was attained, at 60 and 180º.s-1. In the same way, there was no significant modification on the TDF and angle at which the maximal TDF was attained in both angular speeds. In other way, the time to attain maximal TDF (TTDF) at 180º.s-1 was significantly lower after the stretching (Pre - 98.3 ± 27.5 ms and Post - 86.6 ± 30.2 ms). There was significant modification on the torque (60 and 180º.s-1) and time (60º.s-1) at different delta of angle variations, obtained at 60º.s-1 at Control and Post-Stretching conditions. However, there was significant reduction of time after the stretching exercises on delta of angle variations of 90-88º (Pre - 46.6 ± 6.5 ms and Post - 44.1 ± 5.1 ms), 88-85º (Pre - 65.8 ± 7.9 ms and Post - 63.3 ± 4.9 ms) and 85-80º (Pre - 93.3 ± 7.7 ms and Post - 90.0 ± 4.2 ms) at 180º.s-1. With base on these data, it is possible to conclude that PT and TDF do not modify after static stretching, irrespectively on the speed...(Complete abstract click electronic access below)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Considering the importance of muscle strength to functional capacity in the elderly, the study investigated the effects of age on isokinetic performance and torque production as a function of muscle length. Eleven younger (24.2±2.9years) and seventeen older men (62.7±2.5years) were subjected to concentric and eccentric isokinetic knee extension/flexion at 60°.s-1 and 120°.s-1 through a functional range of motion. The older group presented lower peak torque (Nm) than the young group for both isokinetic contraction types (age effect, p<0.001). Peak torque deficits in the older group were near 30% and 29% for concentric and eccentric contraction, respectively. Concentric peak torque was lower at 120.s-1 than at 60.s-1 for both groups (angular velocity effect, p<0.001). Eccentric knee extension torque was the only exercise tested that showed an interaction effect between age and muscle length (p<0.001), which suggested different torque responses to the muscle length between groups. Compared with the young group, the eccentric knee extension torque was 22% to 56% lower in the older group, with the deficits being lower in the shortened muscle length (22-27%) and higher (33-56%) in stretched muscle length. In older men, the production of eccentric knee strength seems to be muscle length-dependent. At more stretched positions, older subjects lose the capacity to generate eccentric knee extension torque. More studies are needed to assess the mechanisms involved in eccentric strength preservation with aging and its relationship with muscle length.