120 resultados para least absolute deviation (LAD) fitting


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study of phosphorus (P) metabolism was carried out using 12 month old Brasileiro de Hipismo breed of horses to determine the P bioavailability available from feeds commonly fed to horses in Brazil. Five different diets were formulated to contain approximately equivalent levels of crude protein and digestible energy, as well as to supply at least 22 g P/horse/day (NRC, 1989). All 5 diets contained 40% Bermuda coastal hay plus 60% concentrate. The 5 different concentrates contained: C1 (corn+ cottonseed meal) C2 (corn grain+soybean meal) C3 (corn+sugarcane yeast), C4 (oat+cottonseed meal), and C5 (oat+soybean meal). The radioisotope (32)p was injected with 30 NIB. Blood, feces and urine were collected for 7 days to evaluate endogenous fecal P and true absorption. Analysis of variance of P intake showed differences due to dietary effects (P < 0.05). Concentrate C3 had the lowest intake (79.68 mg/ kg BW). All of the diets produced positive P retention. Absolute values for P concentrations in plasma, urine, feces and endogenous feces did not vary between diets. Values for endogenous fecal P were independent of the level of P intake, so the correlation between P intake and P endogenous was not significant. P bioavailability values were 50.75; 40.98; 43.50; 51.03 and 57.68% for diets C1 through C5, respectively. However, differences in P bioavailability were found (P < 0.05) between diets. Diets C2 and C3 had lower P bioavailability than the other diets. The P bioavailability of all dietary treatments in this study exceeded NRC (1989) postulations of 35% true P absorption in diets not supplemented with inorganic P. The results of this study indicate that inorganic P supplementation is not needed for growing yearlings fed common Brazilian feeds. Considering the high cost of P supplementation and the risk of environmental P contamination, inorganic phosphorus supplementation for growing yearlings may not be required. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ionospheric scintillations are caused by time-varying electron density irregularities in the ionosphere, occurring more often at equatorial and high latitudes. This paper focuses exclusively on experiments undertaken in Europe, at geographic latitudes between similar to 50 degrees N and similar to 80 degrees N, where a network of GPS receivers capable of monitoring Total Electron Content and ionospheric scintillation parameters was deployed. The widely used ionospheric scintillation indices S4 and sigma(phi) represent a practical measure of the intensity of amplitude and phase scintillation affecting GNSS receivers. However, they do not provide sufficient information regarding the actual tracking errors that degrade GNSS receiver performance. Suitable receiver tracking models, sensitive to ionospheric scintillation, allow the computation of the variance of the output error of the receiver PLL (Phase Locked Loop) and DLL (Delay Locked Loop), which expresses the quality of the range measurements used by the receiver to calculate user position. The ability of such models of incorporating phase and amplitude scintillation effects into the variance of these tracking errors underpins our proposed method of applying relative weights to measurements from different satellites. That gives the least squares stochastic model used for position computation a more realistic representation, vis-a-vis the otherwise 'equal weights' model. For pseudorange processing, relative weights were computed, so that a 'scintillation-mitigated' solution could be performed and compared to the (non-mitigated) 'equal weights' solution. An improvement between 17 and 38% in height accuracy was achieved when an epoch by epoch differential solution was computed over baselines ranging from 1 to 750 km. The method was then compared with alternative approaches that can be used to improve the least squares stochastic model such as weighting according to satellite elevation angle and by the inverse of the square of the standard deviation of the code/carrier divergence (sigma CCDiv). The influence of multipath effects on the proposed mitigation approach is also discussed. With the use of high rate scintillation data in addition to the scintillation indices a carrier phase based mitigated solution was also implemented and compared with the conventional solution. During a period of occurrence of high phase scintillation it was observed that problems related to ambiguity resolution can be reduced by the use of the proposed mitigated solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar os resultados do teste tuberculínico e relacioná-los com a presença ou não de tuberculose em atividade e com a contagem de linfócitos T CD4+/CD8+. MÉTODOS: Foram revisados 802 prontuários de pacientes com síndrome da imunodeficiência adquirida atendidos no período de agosto de 1985 a março de 2003. Cento e oitenta e cinco pacientes realizaram o teste tuberculínico (23,1%) e, destes, 107 eram do sexo masculino (57,8%). A média de idade no grupo de reatores ao teste tuberculínico foi de 30,6 anos, com desvio-padrão de 6,62 anos, e entre os não reatores de 34,45 anos com desvio-padrão de 10,32 anos. Foram constituídos dois grupos de estudo: reatores ao teste tuberculínico, com 28 pacientes, e não reatores ao teste tuberculínico, com 157 pacientes. RESULTADOS: Grande parte dos indivíduos foi pouco responsiva ao teste tuberculínico. Constatou-se, no grupo de reatores, maior porcentagem de indivíduos com tuberculose ativa à época da realização do teste, quando se comparou com os não reatores. Dez pacientes entre os reatores e onze entre os não reatores apresentavam alguma forma clínica de tuberculose em atividade à época da realização do teste, sendo que seis do primeiro grupo e oito do segundo tinham contagem de linfócitos T CD4+ menor que 200 células/mm³. CONCLUSÃO: Indurações maiores do que 5 mm não se relacionaram com contagens absolutas mais altas de células T CD4+.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selection of dominant follicles in cattle is associated with a deviation in growth rate between the dominant and largest subordinate follicle of a wave (diameter deviation). To determine whether acquisition of ovulatory capacity is temporally associated with diameter deviation, cows were challenged with purified LH at known times after a GnRH-induced LH surge (experiment 1) or at known follicular diameters (experiments 2 and 3). A 4-mg dose of LH induced ovulation in all cows when the largest follicle was greater than or equal to 12 mm (16 of 16), in 17% (1 of 6) when it was 11 mm, and no ovulation when it was less than or equal to 10 mm (0 of 19). To determine the effect of LH dose on ovulatory capacity, follicular dynamics were monitored every 12 h, and cows received either 4 or 24 mg of LH when the largest follicle first achieved 10 mm in diameter (experiment 2). The proportion of cows ovulating was greater (P < 0.05) for the 24-mg (9 of 13; 69.2%) compared with the 4-mg (1 of 13; 7.7%) LH dose. To determine the effect of a higher LH dose on follicles near diameter deviation, follicular dynamics were monitored every 8 h, and cows received 40 mg of LH when the largest follicle first achieved 7.0, 8.5, or 10.0 mm (experiment 3). No cows with a follicle of 7 mm (0 of 9) or 8.5 mm (0 of 9) ovulated, compared with 80% (8 of 10) of cows with 10-mm follicles. Thus, follicles acquired ovulatory capacity at about 10 mm, corresponding to about 1 day after the start of follicular deviation, but they required a greater LH dose to induce ovulation compared with larger follicles. We speculate that acquisition of ovulatory capacity may involve an increased expression of LH receptors on granulosa cells of the dominant follicle and that this change may also be important for further growth of the dominant follicle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the effect of insertion torque on micromotion to a lateral force in three different implant designs. Material and methods: Thirty-six implants with identical thread design, but different cutting groove design were divided in three groups: (1) non-fluted (no cutting groove, solid screw-form); (2) fluted (901 cut at the apex, tap design); and (3) Blossomt (Patent pending) (non-fluted with engineered trimmed thread design). The implants were screwed into polyurethane foam blocks and the insertion torque was recorded after each turn of 901 by a digital torque gauge. Controlled lateral loads of 10N followed by increments of 5 up to 100N were sequentially applied by a digital force gauge on a titanium abutment. Statistical comparison was performed with two-way mixed model ANOVA that evaluated implant design group, linear effects of turns and displacement loads, and their interaction. Results: While insertion torque increased as a function of number of turns for each design, the slope and final values increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- standard deviation [SD] = 64.1 +/- 26.8, 139.4 +/- 17.2, and 205.23 +/- 24.3 Ncm, respectively). While a linear relationship between horizontal displacement and lateral force was observed for each design, the slope and maximal displacement increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- SD 530 +/- 57.7, 585.9 +/- 82.4, and 782.33 +/- 269.4 mm, respectively). There was negligible to moderate levels of association between insertion torque and lateral displacement in the Blossomt, fluted and non-fluted design groups, respectively. Conclusion: Insertion torque was reduced in implant macrodesigns that incorporated cutting edges, and lesser insertion torque was generally associated with decreased micromovement. However, insertion torque and micromotion were unrelated within implant designs, particularly for those designs showing the least insertion torque.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of Experiment I were to determine the interval from ovulation to deviation, and diameter of the dominant follicle (DF) and largest subordinate follicle (SF) at deviation in Nelore (Bos indicus) heifers by two methods (observed and calculated). Heifers (n = 12) were examined ultrasonographically every 12 h from ovulation (Day 0) to Day 5. The time of deviation and diameter of the DF and largest SF at deviation did not differ (P > 0.05) between observed and calculated methods. Overall, deviation occurred 2.5 +/- 0.2 d (mean +/- S.E.M.) after ovulation, and diameters for DF and largest SF at deviation were 6.2 +/- 0.2 and 5.9 +/- 0.2 mm, respectively. Experiment 2 was designed to determine the size at which the DF acquires ovulatory capacity in B. indicus heifers. Twenty-nine heifers were monitored every 24 h by ultrasonography, from ovulation until the DF reached diameters of 7.0-8.4 mm (n = 9), 8.5-10.0 mm (n = 10), or >10.0 mm (n = 10). At that time, heifers were treated with 25 mg of pLH and monitored by ultrasonography every 12 h for 48 h. Ovulation occurred in 3 of 9, 8 of 10, and 9 of 10 heifers, respectively (P < 0.05). In summary, there was no significant difference between observed and calculated methods of determining the beginning of follicle deviation. Deviation occurred 2.5 d after ovulation when the DF reached 6.2 mm, and ovulatory capacity was acquired by DF as small as 7.0 mm. (c) 2008 Elsevier B.V. All rights reserved.