48 resultados para laser spectroscopy, ESR, bismuth, lithium-like, QED-test
Resumo:
We present the results of an intracavity Stark spectroscopy experiment on the fundamental state of (CD3OH)-C-13. We use an optically pumped hybrid waveguide FIR laser, CH2F2 as active molecule, and (CD3OH)-C-13 as absorbent molecule. No Brewster window is needed to separate the lasing gas from the absorbing deuterated methanol. An absorption line is assigned as E(l) symmetry (n, K, J): (1,4,18) --> (1,5,18) and its frequency is measured as 63.08631 cm(-1) with a precision of a few parts in 10(7); two more absorptions are reported and a tentative assignment for one of them.
Resumo:
Welding in the dentistry has been used for great part of the specialized dentist-surgeons in the implants area to solve prosthesis supported by implant adaptation problems. The development of new equipments Laser and TIG allowed a larger use of these processes in the prosthesis production. In this work, it was studied welded joints made by Laser and TIG, using commercial purity titanium, cpTi, applied in prosthesis supported by implants. The weld characterizations were carried out by light microscopy, EDS_elementary mapping, microhardness and tensile test. Through metallographic characterization, the weld bead presented a martensitic microstructure in the Laser welding process, originated from shear provoked by deformations in the lattice. This caused structural changes of the transformed area, which determines a fine plate-like morphology. In the weld bead from TIG, besides presenting higher hardness, was observed formation of Widmansttaten structure, which is characteristic of a geometric model, resulted of new phase formation along of the crystallographic plans. The martensitic structure is more refined than Widmansttaten structure, due to the high-speed cooling (10(3)degrees C/s) imposed by the Laser process.
Resumo:
Objective: the aim of this study was to assess, through Raman spectroscopy, the incorporation of calcium hydroxyapatite (CHA; similar to 960 cm(-1)), and scanning electron microscopy (SEM), the bone quality on the healing bone around dental implants after laser photobiomodulation ( lambda 830 nm). Background Data: Laser photobiomodulation has been successfully used to improve bone quality around dental implants, allowing early wearing of prostheses. Methods: Fourteen rabbits received a titanium implant on the tibia; eight of them were irradiated with lambda 830 nm laser ( seven sessions at 48-h intervals, 21.5 J/cm(2) per point, 10 mW, phi similar to 0.0028 cm(2), 86 J per session), and six acted as control. The animals were sacrificed 15, 30, and 45 days after surgery. Specimens were routinely prepared for Raman spectroscopy and SEM. Eight readings were taken on the bone around the implant. Results: the results showed significant differences on the concentration of CHA on irradiated and control specimens at both 30 and 45 days after surgery ( p < 0.001). Conclusion: It is concluded that infrared laser photobiomodulation does improve bone healing, and this may be safely assessed by Raman spectroscopy or SEM.
Resumo:
We use a (CO2)-C-13 laser as optical pumping source to search for new THz laser lines generated from (CH3OH)-C-13. Nineteen new THz laser lines (also identified as far-infrared, FIR) ranging from 42.3 mu m (7.1 THz) to 717.7 mu m (0.42 THz) are reported. They are characterized in wavelength, offset, relative polarization, relative intensity, and optimum working pressure. We have assigned eight laser lines to specific rotational energy levels in the excited state associated with the C-O stretching mode. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
When the carious tissue is eliminated either by conventional methods (with burs) or with lasers, the risk of accidentally damage the surface of adjacent teeth may occur, which hypothetically could lead to a more susceptible surface for canes formation. This in vitro study aims to evaluate the caries resistance of the dental enamel surface irradiated by the Nd:YAG laser applied in conditions simulating accidental exposition. Thirteen third molars were used in this study. The experimental groups were: G1: sound control and control + carious; G2: contact Nd:YAG laser at 0.75, 1, 2, or 3 W; 10 Hz; 3 sec (27, 35, 71, and 106 J/cm(2)); G3: same parameters from G2 + caries artificial induction through the demineralization and demineralization (DES/RE) dynamic model. The caries resistance analysis was evaluated by the superficial morphological aspect through SEM images and also by Ca/P proportion through energy dispersive X-ray spectroscopy (EDX). The micrograph images showed that the Nd:YAG laser changed the normalmorphology of the enamel prisms resulting in a melted and re-solidified surface intensified with the power increase. Significant statistical differences were observed applying the Kruskal-Wallis statistical test (p <= 0.01) among the Nd:YAG laser irradiated groups and the control with caries regarding the Ca/P proportion. As an exception, this was not observed when 3 W; 10 Hz; 3 sec; 106 J/cm(2) was applied and posteriously submitted to a cariogenic challenge. The results indicate that the Nd:YAG laser accidental irradiation at low power settings did not represent risks to the enamel caries resistance.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
We investigated the IR absorption spectrum of 13CH3OH around the frequency of the 10R(20) CO2 laser line. We found two absorption lines which can be excited by 10R(20) and studied the FIR laser emissions excited by this pump line using a waveguide CO2 laser of 300 MHz tunability. We report two new FIR laser lines of large offset, not previously observed due to their weakness and closeness to other stronger lines. We measured the frequencies of five FIR laser lines for the first time by an accurate heterodyne technique and present the complete assignments of the IR-FIR laser systems relative to this pump line. Furthermore we present new frequency values for two FIR laser lines whose frequencies had been previously wrongly measured. Copyright © 1997 Elsevier Science Ltd.
Resumo:
Nitrogen ions were implanted by plasma immersion in Kapton, Mylar and polypropylene, with the objective of forming a diamond-like carbon layer on these polymers. The Raman spectrum of the implanted polypropylene showed typical Diamond-Like Carbon (DLC) graphite (G) and disorder (D) peaks, with an sp 3/sp2 hybridization ratio of approximately 0.4 to 0.6. The XPS analysis of the three implanted polymers also showed peaks of C-C and N-C bonds in the sp3 configuration, with hybridization ratios in the same range as the Raman result. The implanted polymers were exposed to oxygen plasma to test the resistance of the polymers to oxygen degradation. Mass loss rate results, however, showed that the DLC layer formed is not sufficiently robust for this application. Nevertheless, the layer formed can be suitable for other applications such as in gas barriers in beverage containers. Further study of implantation conditions may improve the quality of the DLC layer.
Resumo:
The aim of this investigation was to evaluate the cleaning effect of CO 2 on surface topography and composition of failed dental implant surfaces. Ten failed dental implants were retrieved from nine patients (mean age, 46.33 ± 5.81 years) as a result of early or late failure. The implants were divided into two parts: one side of the implant was irradiated with a CO 2 laser (test side), while the other side did not receive irradiation (control side). The CO 2 laser was operated at 1.2 W in a continuous wave for 40 seconds (40 J energy). The handpiece of the CO 2 laser was kept at a distance of 30 mm from the implant surface, resulting in a spot area of 0.031415 cm 2 (38.20 W/cm 2; 1559 J/cm 2) in scanning mode (cervical-apical). One unused dental implant was used as a negative control for both groups. All implant surfaces were examined by scanning electron mi croscopy (SEM) and energy-dispersive spectrometer x-ray (EDS) for element analysis. SEM showed that the surface of the test sides consisted of different degrees of organic residues, appearing mainly as dark stains similar to those observed on the control sides. None of the test surfaces presented alterations such as crater-like alterations, lava-like layers, or melting compared with the nonirradiated surfaces. Foreign elements such as carbon, oxygen, sodium, calcium, and aluminum were detected on both sides. These results suggest that CO 2 laser irradiation does not modify the implant surface, although the cleaning effect was not satisfactory.
Resumo:
This paper describes a very simple and rapid quantitative reflectance spot test procedure for the determination of methyldopa in pharmaceutical formulations. This method is based on the complexation reaction of methyldopa with molybdate ions yielding a yellow stable complex on filter paper. Reflectance measurements were carried out at 410 nm. Under optimal conditions, the calibration graphs obtained for methyldopa by plotting the optical density of the reflectance signal (A R) vs. the log of the concentration were linear from 6.30 × 10 -3 to 1.89 × 10 -2 mol L -1, with a correlation coefficient of 0.998. The detection limit was 2.74 × 10 -3 mol L -1 (R.S.D. = 1.02%) for methyldopa. The common excipients used as additives in pharmaceuticals do not interfere in the proposed method. The method was applied to determine metyldopa in commercial pharmaceutical formulations. The results obtained by the proposed method compare favorably with those obtained by an official procedure at 95% confidence level. ©2006 Sociedade Brasileira de Química.
Resumo:
The interface formed between the metal and the porcelain of laser-welded Ni-Cr-Mo alloy was studied on a metallurgical basis. The characterization was carried out by using optical microscope, electron scan microscopy and X-ray dispersive spectroscopy techniques and mechanical three-point flexion tests, in the laser-welded region, with and without porcelain. The union of the porcelain with the alloy is possible only after the oxidation of the metallic surface and the subsequent application of a bonding agent known as opaque. The porcelain applied to the base metal and weld bead showed different behaviours - after the flexion test, the base metal showed cracks, while that in the weld bead broke away completely. It was noted that the region subjected to laser welding had lower adherence to the porcelain than the base metal region, due to microstructural refinement of the weld bead. These results can be shown by the X-ray dispersive spectroscopy carried out on the regions studied. The flexion tests demonstrated that the Ni-Cr-Mo alloy subject to laser welding had significant alterations in its mechanical properties after application of the porcelain.
Resumo:
Aim: The aim of this study was to compare the microtensile bond strength of three adhesive systems, using different methods of dentin preparation. Materials and methods: A hundred and eight bovine teeth were used. The dentin from buccal face was exposed and prepared with three different methods, divided in 3 groups: Group 1 (DT)- diamond tip on a high-speed handpiece; Group 2 (CVD)-CVD tip on a ultrasonic handpiece; Group 3 (LA)-Er: YAG laser. The teeth were divided into 3 subgroups, according adhesive systems used: Subgroup 1-Adper Single Bond Plus/3M ESPE (SB) total-etch adhesive; Subgroup 2-Adper Scotchbond SE/3M ESPE (AS) selfetching adhesive; Subgroup 3-Clearfil SE Bond/Kuraray (CS) selfetching adhesive. Blocks of composite (Filtek Z250-3M ESPE) 4 mm high were built up and specimens were stored in deionized water for 24 hours at 37°C. Serial mesiodistal and buccolingual cuts were made and stick-like specimens were obtained, with transversal section of 1.0 mm2. The samples were submitted to microtensile test at 1 mm/min and load of 10 kg in a universal testing machine. Data (MPa) were subjected to ANOVA and Tukey's tests (p < 0.05). Results and conclusion: Surface treatment with Diamond or CVD tips associated with Clearfil SE Bond adhesive produced significantly lower bond strength values compared to other groups. Surface treatment with Er: YAG laser associated with Single Bond Plus or Clearfil SE Bond adhesives and surface treatment with CVD tip associated with Adper Scotchbond SE adhesive produced significantly lower bond strength values compared to surface treatment with diamond or CVD tips associated with Single Bond Plus or Adper Scotchbond SE adhesives. Clinical significance: Interactions between laser and the CVD tip technologies and the different adhesive systems can produce a satisfactory bonding strength result, so that these associations may be beneficial and enhance the clinical outcomes.
Resumo:
This paper describes the development and application of a simple, cheap, and clean method for the quantification of furosemide in urine samples from athletes, to detect doping, using a combined spot test/diffuse reflectance spectroscopy procedure. The method is based on the complexation reaction of furosemide (5-(aminosulfonyl)-4-chloro-2-((furanylmethyl)amino)benzoic acid, dissolved in ethanol, with FeCl3 and the surfactant dodecyltrimethylammonium bromide (DTAB) in aqueous solution, yielding a colored compound on the surface of a filter paper. The reagent concentrations were optimized using a chemometric experimental design. The reflectometric measurements of the complex formed were carried out at 477nm. The linear range obtained was 1.65-9.00×10-3molL-1 of furosemide (R=0.997), and the detection and quantification limits were 4.9×10-4 and 1.62×10-3molL-1, respectively. The proposed method was successfully applied in the analysis of furosemide in spiked urine, demonstrating that it is a reliable alternative method for the detection of furosemide doping in sport. © 2012 Elsevier B.V..