92 resultados para kirschner wire
Resumo:
In some applications like fault analysis, fault location, power quality studies, safety analysis, loss analysis, etc., knowing the neutral wire and ground currents and voltages could be of particular interest. In order to investigate effects of neutrals and system grounding on the operation of the distribution feeders with faults, in this research a hybrid short circuit algorithm is generalized. In this novel use of the technique, the neutral wire and assumed ground conductor are explicitly represented. Results obtained from several case studies using IEEE 34-node test network are presented and discussed.
Resumo:
An 8051-based microcontroller tester has been designed to reduce troubleshooting time of the Electro-Hydraulic Actuators (EHA) installed in fly-by-wire aircrafts. The tester algorithm first evaluates EHA pressure and position sensor signals to emit either a pass or fail message. The evaluation is based on predefined ranges of EHA pressure and position signals. Next, the instrument tests the EHA response capability - a way of dynamic response evaluation, again issuing a suitable response. The instrument proved to be reliable after being successfully evaluated in laboratory and in a real model test airplane. © 2007 IEEE.
Resumo:
This paper investigates the major similarities and discrepancies of three important current decompositions proposed for the interpretation of unbalanced and/or non linear three-phase four-wire circuits. The considered approaches were the so-called FBD Theory, the pq-Theory and the CPT. Although the methods are based on different concepts, the results obtained under ideal conditions (sinusoidal and balanced signals) are very similar. The main differences appear in the presence of unbalanced and non linear load conditions. It will be demonstrated and discussed how the choice of the voltage referential and the return conductor impedance can influence in the resulting current components, as well as, the way of interpreting a power circuit with return conductor. Under linear unbalanced conditions, both FBD and pq-Theory suggest that the some current components contain a third-order harmonic. Besides, neither pq-Theory nor FBD method are able to provide accurate information for reactive current under unbalanced and distorted conditions, what seems to be done by means of the CPT. © 2009 IEEE.
Resumo:
This paper investigates the major similarities and discrepancies among three important current decompositions proposed for the interpretation of unbalanced and/or non linear three-phase four-wire power circuits. The considered approaches were the so-called FBD Theory, the pq-Theory and the CPT. Although the methods are based on different concepts, the results obtained under ideal conditions (sinusoidal and balanced signals) are very similar. The main differences appear in the presence of unbalanced and non linear load conditions. It will be demonstrated and discussed how the choice of the voltage referential and the return conductor impedance can influence in the resulting current components, as well as, the way of interpreting a power circuit with return conductor. Under linear unbalanced conditions, both FBD and pq-Theory suggest that the some current components contain a third-order harmonic. Besides, neither pq-Theory nor FBD method are able to provide accurate information for reactive current under unbalanced and distorted conditions, what can be done by means of the CPT. © 2009 IEEE.
Resumo:
In order to contribute to the discussion of defining a generalized power theory, valid for unbalanced and non linear circuits, this paper discusses the relationship and discrepancies among four modern power theories. Three-phase four-wire circuits, under different conditions, have been analyzed, since the most conflicting and intriguing interpretations take place in case of return conductor occurrence. Simulation results of different load, power supply and line conditions will be discussed in order to elucidate the author's conclusions and to provoke the readers for additional discussions. © 2010 IEEE.
Resumo:
This paper presents some methodologies for reactive energy measurement, considering three modern power theories that are suitable for three-phase four-wire non-sinusoidal and unbalanced circuits. The theories were applied in some profiles collected in electrical distribution systems which have real characteristics for voltages and currents measured by commercial reactive energy meters. The experimental results are presented in order to analyze the accuracy of the methodologies, considering the standard IEEE 1459-2010 as a reference. Finally, for additional comparisons, the theories will be confronted with the modern Yokogawa WT3000 energy meter and three samples of a commercial energy meter through an experimental setup. © 2011 IEEE.
Resumo:
This study compared the effect of the treatment protocol for correcting Class Il malocclusion using the Herbst appliance followed by full fixed Straigh-wire mechanics, in two populations, one Brazilian and one of North American origin As a untreated control sample the data from the University of Michigan Elementary and Secondary School Growth Study (UMGS) was used. Our sample was composed of 12 males and 12 females, with initial mean age of 12 years 7 months and final mean ages of 15 years and 3 months. The Michigan patients comprised 21 females and 7 males, with an initial mean age of 11 years and 9 months and final mean age of 14 years and 4 months. The control sample was paired in number, sex and age to the treated Michigan sample. ln both treated groups, lateral cephalometric radiographs were obtained before the Herbst appliance was cemented and at the end of the fixed appliance phase, The first comparison involved the Brazil group and the untreated controls, which demonstrated that the association of the Herbst appliance followed by fixed Straight-wire appliances provoked positive effects on the dentofacial complex, improving pre-existing maxillo-mandibular relationships, besides increasing dentoalveolar compensations which contributed to correct the malocclusion. The second comparison, involved the Brazl1ian and North-American patients treated with the same protocol. Although the pre-treatment comparison showed that the two groups were not similar in all aspects, they presented almost identical therapeutic modifications, which indicate that the effect of' treatment was very similar. These results point out that, in Class ll treatment, the combination of Herbst/Straight-wire mechanics produce consistent and systematic effects, correcting or minimizing possible skeletal imbalances
Resumo:
Shape memory alloys (SMAs) provide a compact and effective actuation for a variety of mechanical systems. In this paper, a numerical simulation study of a three degree of-freedom airfoil, subjected to two-dimensional incompressible inviscid flow using a SMA is presented. SMA wire actuators are used to control the flap movement of a wing section. Through the thermo-mechanical constitutive equation of the SMA proposed by Brison, we simulate numerically the behavior of a double SMA wire actuator. Two SMA actuators are used: one to move the flap down and the other to move the flap up. Through the numerical results conducted in the present study, the behavior and characteristics of an SMA actuator with two SMA wires are shown the effectiveness of the SMA actuator. In conclusion, this paper shows the feasibility of using SMA wire actuators for flap movement, with success
Resumo:
Increasing air movement over poultry by using fans (ventilation) has become an accepted means of reducing environmental heat stress over the last several years. The purpose of this study was to evaluate the effect of air velocity and exposure time to ventilation on body surface and rectal temperature of broiler chickens. Male broiler chickens aged 36-42 days were placed in individual wire cages and exposed to five different air velocities (5.7, 4.2, 3.1, 2.4, or 1.8 m/sec). Throughout the experiment head, back, leg, and rectal temperatures were monitored every 10 min during a 30-min period for each air velocity. The data showed that exposure time to the wind affected (P<.05) leg and body temperature, with a rapid reduction being observed during the first 10 min. There was a reduction in leg temperature with air velocity of 2 m/sec; however, air velocity lower than 4.5 m/sec was not effective in decreasing head and back temperature. The results suggest that air velocity of 2 m/sec, in air temperature of 29 degrees C, improves heat loss in the birds. The data also indicate that exposure time to ventilation seems to be a critical point in the maintenance of bird thermal homeostasis.
Resumo:
Os experimentos foram conduzidos para avaliar a digestibilidade ileal (CDILEAL) e total (CDTOTAL) do amido e a atividade das enzimas amilase (ATAM) e maltase (ATMAL) em coelhos de 35 e 45 dias alimentados com amido proveniente do milho ou da raspa de mandioca. em cada ensaio foram utilizados 20 coelhos da raça Nova Zelândia Branco, sendo dez machos e dez fêmeas, alojados individualmente em gaiolas de arame e distribuídos em um delineamento inteiramente casualizado. Ao final do período experimental, os animais foram abatidos para retirada de uma amostra do conteúdo digestivo de uma porção do jejuno e do íleo. Os CDILEAL e CDTOTAL do amido da raspa de mandioca (59,25±1,38% e 99,89±0,04%, respectivamente) foram superiores ao do milho (54,21±1,51% e 99,21±0,05%, respectivamente). O CDTOTAL dos animais com 45 dias de idade foi superior ao dos com 35 dias (99,75±0,04% vs 99,35±0,05%). A ATAM, no conteúdo do jejuno e do íleo, foi maior nos animais com 45 dias (0,952±0,118 mmol de glicose/mg/min e 0,647±0,093 mmol de glicose/mg/min, respectivamente) do que nos de 35 (0,469±0,111 mmol de glicose/mg/min e 0,375±0,088 mmol de glicose/mg/min, respectivamente). A ATMAL foi maior nos animais alimentados com raspa de mandioca do que nos que receberam milho (0,061±0,007 mmol de glicose/mg/min vs 0,032±0,007 mmol de glicose/mg/min). Conclui-se que o amido da raspa de mandioca é mais digestível que o do milho, e o sistema enzimático dos coelhos com 35 dias de idade ainda não está suficientemente desenvolvido para que ocorra otimização da digestão do amido.
Resumo:
Coffee (Coffea arabica L.) plants had the pollination process of their flowers studied in three coffee producing regions in Brazil: the first in Ribeirao Preto, state of São Paulo, in September of 2004, the second in Carmo do Paraiba, in the state of Minas Gerais, in October of 2006, and, the third, in Altinopolis, state of São Paulo, in September of 2007. In all these locations the coffee variety used was the 'Catuai Vermelho'. The pollinator species visiting the flowers, the frequency with which the flowers were visited by the insects, and the type of material collected by them ( nectar and/or pollen) were determined by counts taking place at the first 10 minutes of each hour from 7:00 AM till 6:00 PM during the months mentioned above. To estimate the fructification percentage, 25 branches were identified with color threads and protected with wire frames covered with a nylon fabric to prevent them from being visited by insects. Another group of 25 branches was similarly identified but remained without any covering so that their flowers were thus freely visited by insects. on the average, the most frequent pollinator was the Africanized bee Apis mellifera (73.7%) followed by the bee Trigona spinipes (14.5%), and Tetragonisca angustula (9.5%). The Africanized bee collected nectar and pollen to almost the same extent: 58.5% of the first and 41.5% of the second. To collect nectar, that species increased its visiting frequency up to 1:00 PM. To collect pollen, A. mellifera visited the flowers up to 1:00 PM with frequency peaks between 8:00 and 9:00 AM. T. spinipes collected pollen (58,5%) and nectar (41.5%). T. angustula collected only pollen. The branches freely visited by insects produced 181 grains on the average whereas those covered with the nylon fabric produced only 81 grains, this meaning a reduction of 55.25% in grain production. Coffee grains produced on the freely visited branches had a mean weight (1.13 g) significantly superior to that of those produced on the covered branches (0.94 g).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Plasma treatments are frequently employed to modify surface properties of materials such as adhesivity, hydrophobicity, oleophobicity etc. Present work deals with surface modification of common commercial polymers such as polyethylene terephthalate (PET) and polyurethane (PU) by an air dielectric barrier discharge (DBD) at atmospheric pressure. The DBD treatment was performed in a plain reactor in wire-duct geometry (non-uniform field reactor), which was driven by a 60 Hz power supply. Material characterization was carried out by water contact angle measurements, atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS). The plasma-induced modifications are associated with incorporation of polar oxygen and nitrogen containing groups on the polymer surface. The AFM analysis reveals that the plasma treatment roughens the material surface. Due to these structural and morphological changes the surface of DBD-treated polymers becomes more hydrophilic resulting in enhanced adhesion properties. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The conventional radiographic technique using industrial radiographic films is with the days finishing. The Digital Radiography is taking place in several sectors, e.g., the medical, aerospace, security, automotive, etc. In addition to representing a technological trend, it has been demonstrated that digital radiography offers a series of benefits in terms of productivity, sensitivity, environmental aspects, image treatment tools, cost reduction, etc. If one weld seam to be inspected is from a serried product, as example a pipe, the best option to be implemented is the Flat Panel Detector with this equipment is possible to reduce the obtaining digital radiographic images in place of films and reducing the inspection cycle time due to its high degree of automation. In the experiments described in this paper this new technique was tested and the results were compared with those obtained by the conventional radiography. The welded specimens were prepared using the submerged-arc welding process and small artificial cracks of the most varied dimensions, present in the specimens, were used to establish a comparison of the sensitivities presented by the techniques employed After conducting several experiments, the digital method presented the highest sensitivity to the wire-type Image Quality Indicator (IQI) and in the detection of small defects, leading to the conclusion that the use of digital radiography using the flat-panel detector offers advantages over the conventional technique [1, 2]. This work was carried out based on the API 5L Edition 2004 [3] and ISO 3183 Edition 2007 [4] specifications.
Resumo:
Electrodeposition of thin copper layer was carried out on titanium wires in acidic sulphate bath. The influence of titanium surface preparation, cathodic current density, copper sulphate and sulphuric acid concentrations, electrical charge density and stirring of the solution on the adhesion of the electrodeposits was studied using the Taguchi statistical method. A L(16) orthogonal array with the six factors of control at two levels each and three interactions was employed. The analysis of variance of the mean adhesion response and signal-to-noise ratio showed the great influence of cathodic current density on adhesion. on the contrary, the other factors as well as the three investigated interactions revealed low or no significant effect. From this study optimized electrolysis conditions were defined. The copper electrocoating improved the electrical conductivity of the titanium wire. This shows that copper electrocoated titanium wires could be employed for both electrical purpose and mechanical reinforcement in superconducting magnets. (C) 2008 Elsevier B.V. All rights reserved.