165 resultados para glomerulus capillary
Resumo:
This study aimed to compare the glycemic values obtained with a glucometer with those determined by a colorimetric enzymatic assay in venous blood as well as to evaluate the possibility of using capillary blood samples of dogs with diabetes mellitus. A group with 30 diabetic dogs was formed and from each dog three blood samples were obtained for glycemic evaluations by different methods and blood collection sites. The mean glycemic values showed no significant difference between the different sites of blood collection and methods (P=0.90). Venous, pinna and carpal pad blood glucose showed excellent correlation with the colorimetric enzymatic assay (r=0.98; r=0.95 and r=0.96 respectively) and the obtained values fit properly the clinically acceptable intervals in the error grid analysis. The present study revealed that carpal pad, venous and pinna glucose measurements are clinically acceptable and this method is feasible for use in hospitalized diabetic dogs. The sample attainment of carpal pad proved to be effective and a viable alternative. Further work is necessary to assess the utility of this technique in a home environment.
Resumo:
The use of chemical preservative compounds is common in the food products industry. Caramel color is the most usual additive used in beverages, desserts, and breads worldwide. During its fabrication process, 2- and 4-methylimidazole (MeI), highly carcinogenic compounds, are generated. In these cases, the development of reliable analytical methods for the monitoring of undesirable compounds is necessary. The primary procedure for the analysis of 2- and 4-MeI is using LC- or GC-MS techniques. These procedures are time-consuming and require large amounts of organic solvents and several pretreatment steps. This prevents the routine use of this procedure. This paper describes a rapid, efficient, and simple method using capillary electrophoresis (CE) for the separation and determination of 2- and 4-MeI in caramel colors. The analyses were performed using a 75 μm i.d. uncoated fused-silica capillary with an effective length of 40 cm and a running electrolyte consisting of 160 mmol L-1 phosphate plus 30% acetonitrile. The pH was adjusted to 2.5 with triethylamine. The analytes were separated within 6 min at a voltage of 20 kV. Method validation revealed good repeatability of both migration time (<0.8% RSD) and peak area (<2% RSD). Analytical curves for 2- and 4-MeI were linear in the 0.4-40 mg L-1 concentration interval. Detection limits were 0.16 mg L-1 for 4-MeI and 0.22 mg L-1 for 2-MeI. The extraction recoveries were satisfactory. The developed method showed many advantages when compared to the previously used method. © 2013 American Chemical Society.
Resumo:
A method based on capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C4D) for determination of two important phosphodiesterase type-5 inhibitors (sildenafil and vardenafil) is introduced. The background electrolyte (BGE) consisted of an aqueous solution of 500 mmol L-1 acetic acid, and the capillary was previously treated with polybrene solution to prevent cationic analytes from adsorbing onto the inner surface. Although the analytes migrate in the counter flow, the total time is short. An instrument with two C4D detectors allowed a seamless transition from a fast method (less than one minute) but of low-efficiency using the first detector to a more efficient method using the second detector. The analysis of commercial tablets showed no significant difference between CE-C4D and HPLC methods. Conductivity detection is a well-known low selectivity detection scheme, which in conjunction with the high mobility of the co-ion in the BGE (hydroxonium) allows one to predict that other cationic analogues of sildenafil can also be detected. This is an interesting feature given the increasing number of compounds in this class. © 2013 The Royal Society of Chemistry.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This work presents a numerical model to simulate refrigerant flow through capillary tubes, commonly used as expansion devices in refrigeration systems. The flow is divided in a single-phase region, where the refrigerant is in the subcooled liquid state, and a region of two-phase flow. The capillary tube is considered straight and horizontal. The flow is taken as one-dimensional and adiabatic. Steady-state condition is also assumed and the metastable flow phenomena are neglected. The two-fluid model, considering the hydrodynamic and thermal non-equilibrium between the liquid and vapor phases, is applied to the two-phase flow region. Comparisons are made with experimental measurements of the mass flow rate and pressure distribution along two capillary tubes working with refrigerant R-134a in different operating conditions. The results indicate that the present model provides a better estimation than the commonly employed homogeneous model. Some computational results referring to the quality, void fraction, velocities, and temperatures of each phase are presented and discussed.
Resumo:
OBJECTIVE: to evaluate the structure, process and results of the Capillary Blood Glucose Self-monitoring Program in a Brazilian city. METHOD: epidemiological, cross-sectional study. The methodological framework of Donabedian was used to construct indicators of structure, process and outcome. A random sample (n = 288) of users enrolled and 96 health professionals who worked in the program was studied. Two questionnaires were used that were constructed for this study, one for professionals and one for users, both containing data for the evaluation of structure, process and outcome. Anthropometric measures and laboratory results were collected by consulting the patients' health records. The analysis involved descriptive statistics. RESULTS: most of the professionals were not qualified to work in the program and were not knowledgeable about the set of criteria for patient registration. None of the patients received complete and correct orientations about the program and the percentage with skills to perform conducts autonomously was 10%. As regards the result indicators, 86.4% of the patients and 81.3% of the professionals evaluated the program positively. CONCLUSION: the evaluation indicators designed revealed that one of the main objectives of the program, self-care skills, has not been achieved.
Resumo:
Darunavir, a protease inhibitor used in the treatment of HIV infection, presents few methods for its determination in pharmaceuticals. Infrared (IR) spectroscopy offers the possibility of obtaining spectra relatively quickly, providing interesting information, analytically, qualitatively or quantitatively. Capillary electrophoresis (CE) performs separations of high efficiency in shorter time with reagents and samples in small quantity. These two methods are cost-benefitted when we evaluate the green level and the cost of analysis. Faster and cheaper methods without generating organic waste by IR and CE for the quantification of darunavir were developed and validated, focusing socioeconomic impact of analytical decisions. If the cost of acquisition, maintenance, production, analysis and conditioning of drugs and pharmaceuticals is high, consequently the price of this product in the market will be higher and it cannot be accessible to the patient. Treatment failure not only affects the quality of life of patients, but also contributes significantly to the economic burden of the health system. In this context there is a tool called Analysis of the Life Cycle, which comes to make us think in a multidimensional way focusing the whole, the parts and especially the interaction among the parts of a system.
Resumo:
Darunavir (DRV) is a protease inhibitor used in the treatment of HIV infection, which constitutes a keystone in the therapy of patients infected with this virus. There is no monograph described in official compendia. The literature provides few methods of analysis for the determination of DRV in pharmaceuticals which include TLC, IR, UPLC, HPLC, HPLC-MS, HPLC-MS/MS, but there are no reports of the use of capillary electrophoresis (CE) for the determination of this drug. Thus, this research proposed the development and validation of a CE method for the determination of DRV in tablets. The method was completely validated according to the International Conference on Harmonization guidelines, showing linearity, selectivity, precision, accuracy and robustness. The migration was achieved in less than 1 minute using fused-silica uncoated capillary with an id of 50 μm and total length of 21 cm and voltage of +20 kV. The sample injection was performed in the hydrodynamic mode. The method was linear over the concentration range of 50-200 μg mL-1 with correlation coefficient 0.9998 and limits of detection and quantification of 7.29 and 22.09 μg mL-1, respectively. The drug was subjected to acid, base, oxidation and photolysis degradation. Degradation products were found interfering with the assay of DRV, therefore the method can be regarded as stability indicating. The validated method is useful and appropriate for the routine quality control of DRV in tablets.
Resumo:
O objetivo do presente estudo foi reportar a infecção por Trypanosoma sp. em tuviras (Gymnotus aff. inaequilabiatus) oriundas do Pantanal Sul-mato-grossense, Brasil. Dez peixes provenientes do rio Paraguai, Pantanal Sul-mato-grossense, foram avaliados quanto à presença de hemoflagelados. Tripomastigotas de Trypanosoma sp. foram observados nas extensões sanguíneas de três peixes (30% de prevalência), e algumas formas encontravam-se em divisão. Por meio do exame a fresco e da centrifugação do sangue em capilar de hematócrito como métodos para diagnóstico, a taxa de prevalência foi de 80%. Esse é o primeiro relato de Trypanosoma sp. em tuviras no Brasil.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Foram examinados 20 eqüinos adultos portadores de abdômen agudo e submetidos à laparotomia. Dez recuperaram-se sem intercorrência pós-operatória (G1) e 10 foram a óbito sete a 10 dias após a cirurgia, com sinais de choque séptico (G2). Avaliaram-se temperatura retal, freqüências cardíaca e respiratória, tempo de preenchimento capilar e teores plasmáticos das proteínas de fase aguda - fibrinogênio, ceruloplasmina, proteína C-reativa, antitripsina, haptoglobina e glicoproteína ácida -, antes e até sete dias após a laparotomia. As leucometrias às 72h e no sétimo dia pós-operatório dos eqüinos que foram a óbito foram, respectivamente, 34,6% e 57,1%, mais altas que a dos animais curados. Os maiores valores de proteína de fase aguda ocorreram no sétimo dia após a cirurgia; os percentuais de elevação de fibrinogênio, antitripsina, glicoproteina ácida, proteína C-reativa, ceruloplasmina e haptoglobina de eqüinos do G2 em relação ao G1 foram 46,8%, 67,9%, 91,9%, 112,2%, 126,9% e 186,2%, respectivamente.
Resumo:
As afecções gastrintestinais dos cavalos são agravadas por complicações como a laminite, cuja etiopatogenia está relacionada à degradação da membrana basal do tecido laminar por metaloproteinases (MMPs). A ativação das MMPs pode ocorrer devido à liberação local de citocinas inflamatórias ou enzimas provenientes de leucócitos infiltrados no tecido laminar. O objetivo deste trabalho foi avaliar as alterações morfológicas do tecido laminar de equinos com síndrome cólica letal e sua provável associação com parâmetros clínicos e laboratoriais. Observou-se intensa destruição da arquitetura laminar, principalmente nos animais com alterações físicas e laboratoriais mais acentuadas, como tempo de preenchimento capilar prolongado (TPC), membranas mucosas congestas, taquicardia, hemoconcentração e redução nas contagens de plaquetas e leucócitos. Os resultados sinalizam o provável momento do desenvolvimento de lesões do tecido laminar em equinos com síndrome cólica, no qual é possível adotar medidas preventivas contra a laminite.
Resumo:
No presente estudo, avaliou-se a eficácia do emprego do peritônio bovino, conservado em glicerina a 98%, no reparo de lesões induzidas no tendão calcâneo (TC) de cães, quando um fragmento de aproximadamente 1cm do TC foi excisado e o espaço resultante preenchido por um fragmento de peritônio. Foram utilizados 21 cães, pesando entre 10 e 15kg, divididos em 7 grupos de 3, sacrificados aos 02, 07, 15, 30, 60, 90 e 120 dias de pós-operatório. Analisaram-se os aspectos clínico-cirúrgicos referentes à recuperação funcional motora, bem como, a integração do peritônio com o tecido tendíneo mediante avaliação macroscópica, por microscopia óptica e por microscopia eletrônica de varredura. Clinicamente, verificou-se que, por volta do 55º dia de pós-operatório, os animais já apresentavam deambulação normal e que o neotendão apresentou resistência suficiente para suportar o estresse normalmente aplicado ao TC. Microscopicamente, o peritônio implantado esteve presente em todos os períodos de observação. Proliferação fibroblástica e neoformação vascular foram observadas de forma incipiente no segundo dia; entretanto, no sétimo dia de pós-operatório, esta condição foi exacerbada. Com a evolução, as fibras de peritônio tendiam a se dissociar, entrando em estreita associação com fibras conjuntivas, fibroblastos e colágeno. Aos 30, 60, 90 e 120 dias de pós-operatório, notava-se maior presença de colágeno que se tornava cada vez mais organizado. Concluiu-se que o peritônio estimulou uma rápida deposição de tecido conjuntivo com mínima reação inflamatória, sendo incorporado ao tecido cicatricial e servindo como alicerce para o desenvolvimento de um novo tecido, restabelecendo assim a estrutura do tendão.
Resumo:
The adhesion force between an atomic force microscope (AFM) tip and sample surfaces, mica and quartz substrates, was measured in air and water. The force curves show that the adhesion has a strong dependence on both the surface roughness and the environmental conditions surrounding the sample. The variability of the adhesion force was examined in a series of measurements taken at the same point, as well as at different places on the sample surface. The adhesion maps obtained from the distribution of the measured forces indicated regions contaminated by either organic compounds or adsorbed water. Using simple mathematical expressions we could quantitatively predict the adhesion force behavior in both air and water. The experimental results are in good agreement with theoretical calculations, where the adhesion forces in air and water were mostly associated with capillary and van der Waals forces, respectively. A small long-range repulsive force is also observed in water due to the overlapping electrical double-layers formed on both the tip and sample surfaces.