637 resultados para dental bleaching


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study evaluated the effect of 10% sodium ascorbate (10SA), in gel (10SAg) or aqueous solution (10SAs) formulations, on fracture resistance of endodontically treated tooth submitted to dental bleaching procedures with 15% hydrogen peroxide associated with titanium dioxide (15HP-TiO2) nanoparticles and photoactivated by LED-laser. Material and methods: Forty maxillary premolars were endodontically-treated and embedded in acrylic resin up to the cement-enamel junction. The specimens were divided into four groups (n=10): G1 (negative control): no bleaching, coronal access restored with composite resin; G2 (positive control): three dental bleaching sessions using 15HP-TiO2 and LED-laser photoactivation and restored with composite resin (positive control); G3 (10SAg): similar procedures to G2, but applied 10SA, in gel formulation, for 24 hours before restoration; G4 (10SAs): similar procedures to G3, but applied 10SA, in aqueous solution formulation. The 15HP-TiO2 was applied on buccal and lingual surfaces of the crown tooth and inside the pulp chamber and photoactivated by LED-laser. Between each bleaching session, the teeth were maintained in artificial saliva, at 37oC, for 7 days. In sequence, the teeth were submitted to fracture resistance testing using an eletromechanical machine test. The data was analyzed using Kruskal Wallis test (p = 0.05) Results: There are no differences significant among the groups in relation to fracture resistance of endodontically treated teeth (p>0.05). Conclusions: The use of 10% sodium ascorbate, in gel or aqueous solution formulations, did not interfered on the fracture resistance teeth after dental bleaching using 15HP-TiO2 and LED-laser photoactivation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In-office dental bleaching has been subject of several studies. Generally those studies quantify through visual analysis, the shade reduction of the teeth submitted to different bleaching protocols (light sources, bleaching agent concentrations and irradiation time). The objective of this work is the determination of the influence of four irradiation protocols on the obtainment of better aesthetic results using a colorimetric spectrophotometer that quantifies color changes in each situation imposed. Forty bovine incisors were selected in function of similar anatomic characteristics; a concentrated coffee solution was used to stain the teeth. A commercial spectrophotometer was used to measure the color changes during evolution of the experiment (stain and bleaching phases) and the obtained data was analyzed by the ANOVA test. The obtained data showed the evolution of teeth color during the staining period, as well as, the color reduction that each bleaching protocol achieved. Based on our findings it is possible to conclude that bleaching protocols with larger irradiation periods did not showed significant differences when compared with shorter irradiation protocols, in that way the use of protocols with 30 min or more of consecutive irradiation are not clinically justified and also can cause several side effects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aware of the diffusion capacity of bleaching in the dental tissues, many orthodontists are subjecting their patients to dental bleaching during orthodontic treatment for esthetic purposes or to anticipate the exchange of esthetic restorations after the orthodontic treatment. For this purpose specific products have been developed in pre-loaded whitening trays designed to fit over and around brackets and wires, with clinical efficacy proven. Objective: The objective of this study was to evaluate, through spectrophotometric reflectance, the effectiveness of dental bleaching under orthodontic bracket. Material and Methods: Thirty-two bovine incisors crown blocks of 8 mm x 8 mm height lengths were used. Staining of tooth blocks with black tea was performed for six days. They were distributed randomly into 4 groups (1-home bleaching with bracket, 2- home bleaching without bracket, 3- office bleaching with bracket, 4 office bleaching without bracket). The color evaluation was performed (CIE L * a * b *) using color reflectance spectrophotometer. Metal brackets were bonded in groups 1 and 3. The groups 1 and 2 samples were subjected to the carbamide peroxide at 15%, 4 hours daily for 21 days. Groups 3 and 4 were subjected to 3 in-office bleaching treatment sessions, hydrogen peroxide 38%. After removal of the brackets, the second color evaluation was performed in tooth block, difference between the area under the bracket and around it, and after 7 days to verified color stability. Data analysis was performed using the paired t-test and two-way variance analysis and Tukey’s. Results: The home bleaching technique proved to be more effective compared to the office bleaching. There was a significant difference between the margin and center color values of the specimens that were subjected to bracket bonding. Conclusions: The bracket bond presence affected the effectiveness of both the home and office bleaching treatments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to evaluate the color, translucency and fluorescence of bovine enamel and dentin submitted to different bleaching modalities. Pairs of enamel and dentin discs (3 mm in diameter) were obtained from 150 bovine teeth. In 75 of the pairs, one specimen had the enamel removed (Dentin Group). The dentin was removed from one specimen of the remaining 75 pairs (Enamel Group) and the other specimen was left unaltered (Enamel + Dentin). The evaluation of color, translucency and fluorescence was performed with a spectrophotometer using the CIE L* a* b*. Each group was subdivided into three subgroups: Control, composed of specimens that were not bleached, and two experimental subgroups, bleached with either 10% carbamide peroxide (CP10%) or 35% hydrogen peroxide (HP35%). The CP10% bleaching gel was applied 2 h/day for 14 days. The HP35% bleaching agent was applied using two applications of 30 min each, with a one week interval between each application. When not being bleached, the specimens were immersed in artificial saliva. The color, translucency and fluorescence ratings were assessed using spectrophotometry 7 days after the treatment. Regarding color, significant differences were found between bleaching techniques in the groups Enamel and Enamel + Dentin, with a higher color difference for HP35%. Bleaching did not change the translucency of the dental tissues. There were significant differences for fluorescence for the HP35% subgroups of Dentin and Enamel + Dentin, and for the CP10% subgroup of Enamel. Dental bleaching changed the color and fluorescence of the dental tissues, however translucency was not affected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Context: The possibility of bleaching vital teeth with peroxide-based products considerably revolutionized esthetic dentistry. Aim: The aim of this clinical study was to evaluate tooth color change and dental sensitivity after exposure to preloaded film containing a 10% hydrogen peroxide whitening system (Opalescence Trθswhite Supreme). Materials and Methods: A total of 13 volunteers, aged 18 to 25 years, participated in this study. The patients used the whitening system once a day for 60 minutes during the 8-day study. For maxillary incisors and canines, the color change was visually evaluated with the Vita color scale before, immediately, and six months after the treatment. Tooth sensitivity was evaluated during the daily gel applications. All whitening applications were done in office and under the supervision of a dental professional. Statistical Analysis Used: The results were analyzed using the Friedman Test (nonparametric repeated measures ANOVA) at a level of 5%, and Dunn's Multiple Comparison Test at the level of 5%. Results: It was verified that the original mean color values observed at the baseline analysis differed significantly from those observed immediately after bleaching, as well as from those seen in the analysis at six months ( P = 0.001). There was no significant difference between the mean color values observed in the immediate time and in the analysis at six months ( P = 0.474). No tooth sensitivity was observed in any patients. Conclusion: It was concluded that the bleaching technique using the 10% hydrogen peroxide system was effective in a short period of time without tooth sensitivity during applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The dental bleaching is known for many years. Recently a technique employing light has open up new and exciting possibilities. Besides its vast application there are still many important points to be understood about teeth photon bleaching. In this work we present an in vitro experiment to explore the main mechanisms involved during the photon action in tooth whitening. Our results indicated that light at same wavelengths are great absorbed by pigments creating a local heating which considerably increase the bleaching rate. This results in a fast reaction without heating the whole dental structure. We discuss details of our experiment. Work supported by Fapesp and CNPq.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Examining three bleaching systems, this in vivo clinical trial evaluated the relationship among tooth sensitivity, light activation, and agent concentration, and it correlated dental sensitivity with tooth thickness.Materials and Methods: Eighty-seven volunteer patients were included. Inclusion criteria were the presence of anterior teeth without restorations as well as the absence of a previous bleaching experience and absence of non-carious cervical lesions or dental pain. Exclusion criteria included pregnancy or breastfeeding, a maximum of TF3 hypoplasia, tetracycline-fluorosis stains, malpositioned teeth, orthodontic treatment, periodontal disease, and/or analgesic/anti-inflammatory intake. Patients were randomly assigned to three bleaching groups: Group A (n=25) was treated with 15% H2O2 and nitrogenous-titanium-dioxide and was light activated (Lase Peroxide Lite, DMC, SaoCarlos, Sao Paulo, Brazil); Group B (n=27) was treated with 35% H2O2 and was light activated (Lase Peroxide Sensy, DMC); and Group C (n=35) was treated with 35% H2O2 (White Gold Office, Dentsply, 38West Clark Ave., Milford, USA) without light activation. Tooth sensitivity (TS) was self-reported by the patients using the visual analog scale (VAS) at baseline (TSO), immediately after treatment (TSI), and at seven days after treatment (TS7). In 46 patients, tooth thickness was determined by computed tomography. TSO, TSI, and TS7 were compared between the A and B groups to determine the effect of concentration and between the B and C groups to determine the effect of light using analysis of covariance. The correlation between tooth thickness and TSI was determined by Spearman Rho test (SPSS 15).Results: Eighty-seven patients were evaluated at baseline, and 61 were evaluated at seven days. Separated by groups, tooth sensitivity, expressed as VAS value at the time points TS0, TS1, and TS7, respectively, were as follows: Group A: 13.76 +/- 13.53, 24.40 +/- 25.24, and 5.94 +/- 5.5; Group B: 15.07 +/- 18.14, 42.4 +/- 31.78, and 8.68 +/- 17.99; and Group C: 10.80 +/- 14.83, 31.51 +/- 29.34, and 7.24 +/- 9.2. Group A showed significantly lower tooth sensitivity than group B at TSI (p=0.032). No differences were observed in the tooth sensitivities between groups B and C. No correlation was encountered between tooth thickness and tooth sensitivity immediately after treatment (Rho=-0.088,p=0.563). The median tooth thickness was 2.78 +/- 0.21 mm.Conclusions: Increases in the concentration of bleaching agents directly affect tooth sensitivity, and LED/laser activation and tooth thickness are not correlated with tooth sensitivity after dental bleaching.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aim: To investigate pulp chamber penetration of bleaching agents in teeth following restorative procedures. Methodology: Bovine lateral incisors were sectioned 3 mm apical to the cemento-enamel junction and the coronal pulpal tissue was removed. Teeth were divided into six groups (n = 10): G1, G2 and G3 were not submitted to any restorative procedure, while G4, G5 and G6 were submitted to Class V preparations and restored with composite resin. Acetate buffer was placed in the pulp chamber and treatment agents were applied for 60 min at 37°C as follows: G1 and G4, immersion into distilled water; G2 and G5, 10% carbamide peroxide (CP) exposure; G3 and G6, 35% CP bleaching. The buffer solution was removed and transferred to a glass tube where leuco crystal violet and horseradish peroxidase were added, producing a blue solution. The optical density of the blue solution was determined spectrophotometrically at 596 nm. A standard curve made with known amounts of hydrogen peroxide was used to convert the optical density values of the coloured samples into microgram equivalents of hydrogen peroxide. Data were submitted to ANOVA and Tukey's test (5%). Results: Amounts of hydrogen peroxide found in the pulp chamber of G2 and G5 specimens (0.1833 ± 0.2003 μg) were significantly lower (P = 0.001) when compared to G3 and G6 specimens (0.4604 ± 0.3981 μg). Restored teeth held significantly higher (P = 0.001) hydrogen peroxide concentrations in the pulp chamber than intact teeth. Conclusion: Higher concentrations of the bleaching agent produced higher levels of hydrogen peroxide in the pulp chamber, especially in restored teeth.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This study measured the critical temperature reaching time and also the variation of temperature in the surface of the cervical region and within the pulp chamber of human teeth submitted to dental bleaching using 35% hydrogen peroxide gel activated by three different light sources. The samples were randomly divided into 3 groups (n = 15), according to the catalyst light source: Halogen Light (HL), High Intensity Diode Laser (DL), and Light Emmited Diode (LED). The results of temperature variation were submitted to the analysis of variance and Tukey test with p < 0.05. The temperature increase (mean value and standard deviation) inside the pulp chamber for the HL group was 6.8 ± 2.8°C; for the DL group was 15.3 ± 8.8°C; and for the LED group was 1.9 ± 1.0°C for. The temperature variation (mean value and standard deviation) on the tooth surface, for the group irradiated with HL was 9.1 ± 2.2°C; for the group irradiated with DL were 25.7 ± 18.9°C; and for the group irradiated with LED were 2.6 ± 1.4°C. The mean temperature increase values were significantly higher for the group irradiated with DL when compared with groups irradiated with HL and LED (p < 0.05). When applying the inferior limits of the interval of confidence of 95%, an application time of 38.7 s was found for HL group, and 4.4 s for DL group. The LED group did not achieve the critical temperatures for pulp or the periodontal, even when irradiated for 360 s. The HL and DL light sources may be used for dental bleaching for a short period of time. The LED source did not heat the target tissues significantly within the parameters used in this study. © 2010 Pleiades Publishing, Ltd.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The following is a clinical case report of a patient whose chief complaint was the presence of generalized spacing in the maxillary anterior segment following orthodontic treatment. After meticulous clinical analyses and discussions of the clinical procedures to be adopted, dental bleaching was performed in both arches with 10% hydrogen peroxide (Opalescence Trèswhite Supreme 10% Hydrogen Peroxide - Ultradent Products, Inc., South Jordan, USA) after the conclusion and stabilization of orthodontic treatment. Then, the orthodontic appliance was removed and the diastemas in the maxillary anterior teeth were closed with Amelogen Plus (Ultradent Products, Inc., South Jordan, USA) resin composite. It was observed that the association of orthodontic, bleaching, and restorative procedures was capable of restoring dental shape, function, and esthetics, allowing the patient to smile without hesitation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)