22 resultados para consult
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Congenital toxoplasmosis is a serious public health case, for it causes irreversible damage to the embryo/fetus, which may cause its death. The identification and the care to pregnant women with suspect acute toxoplasmosis (IgM+) is performed in prenatal monitoring. This study aimed to measure the incidence and know the profile of positive pregnant women for toxoplasmosis in a Basic Health Unit (BHU) in Matão - SP, between the years 2011 to 2013. This is a retrospective descriptive study, from the medical records of pregnant women attended. The project was approved by the Municipal Departament of Health and BHU was chosen along the Municipal Epidemiological Surveillance. From 2011 to 2013, 189 women began prenatal care in the unit, an annual median of 71(±26.91), of which 17 (8.99%) were positive for the serological test indicative of acute phase (IgM+). The distribution over the trial period was: four cases in 2011, twelve cases in 2012 and one in 2013. Pregnant women IgM positive for toxoplasmosis attend by BHU were: age 24(±5.47) years; color: equally distributed among white, black and brown; as the number of pregnancies: multiparous (2±0.97), most of them with a cesarean delivery as obstetric history and possessed no other risk factors associated with pregnancy (94.12%); gave entrance at BHU with 13.65(±7.35) weeks of gestation and had a median of 5(±2.36) consultation on their prenatal care. The examination for toxoplasmosis was requested as recommended by the Health Ministry (HM) and the medication prescribed was Roxamicina® - spiramycin, as soon as the test results (IgM+) arrived. Of the 17 pregnant women, only 10 completed the pre-natal at BHU - attendance at the postpartum consult (58.8%). Of these, the deliveries were vaginal (55.55%), made preterm with 36.5 weeks of gestation at the Municipal Hospital. The babies were born alive (100%) with the weight of 2.68(±0.77) Kg and required special care hospital scope. From the ...
Resumo:
This study aimed to evaluate the force degradation of synthetic elastics over time using dynamic biomechanical tests in order to find clinical parameters of what size of elastic and frequency of exchange should be used in orthodontic therapy. It was used 240 elastics of Dental Morelli, sizes 1/8", 3/16", 1/4 "and 5/16", medium force, divided in four groups. In each group was measured forces at different times, from immediate to 72 hours after immersion in water at 37°C and incubated stretched to 600% of its initial inner diameter. Tensile tests were performed on a universal testing machine EMIC DL2000 submerged in distilled water maintained at 37°C. Data were analyzed using SPSS version 16.0, by the Analysis of Variance (One-Way) with Tukey´s post test. There was a greater increase in pattern of force decay of immediate measurement until 24 hours in all sizes of synthetic elastics, from which it was observed a decrease in force progressively smaller, with the exception of 5/16´´ elastic with a maximum force decay occurred at 12h. It was concluded that: the elastic synthetic Dental Morelli suffered significant force degradation over time, with reduction of approximately 70% of the initial force during 24 hours of stretching, followed by a progressively smaller decrease; the amount of stretch for a ideal force in intermaxillary therapies depends on the distance between the points of attachment of elastic, being necessary to consult the tables to choose the size, force and frequency of replacement.
Resumo:
Structured AbstractObjectivesTo investigate the 3D morphological variations in 169 temporomandibular ioint (TMJ) condyles, using novel imaging statistical modeling approaches.Setting and sample populationThe Department of Orthodontics and Pediatric Dentistry at the University of Michigan. Cone beam CT scans were acquired from 69 subjects with long-term TMJ osteoarthritis (OA, mean age 39.115.7years), 15 subjects at initial consult diagnosis of OA (mean age 44.914.8years), and seven healthy controls (mean age 4312.4years).Materials and methods3D surface models of the condyles were constructed, and homologous correspondent points on each model were established. The statistical framework included Direction-Projection-Permutation (DiProPerm) for testing statistical significance of the differences between healthy controls and the OA groups determined by clinical and radiographic diagnoses.ResultsCondylar morphology in OA and healthy subjects varied widely with categorization from mild to severe bone degeneration or overgrowth. DiProPerm statistics supported a significant difference between the healthy control group and the initial diagnosis of OA group (t=6.6, empirical p-value=0.006) and between healthy and long-term diagnosis of OA group (t=7.2, empirical p-value=0). Compared with healthy controls, the average condyle in OA subjects was significantly smaller in all dimensions, except its anterior surface, even in subjects with initial diagnosis of OA.ConclusionThis new statistical modeling of condylar morphology allows the development of more targeted classifications of this condition than previously possible.
Resumo:
The aim of this study is to evaluate through a literature review, the soft tissue response in contact with zirconia abutments, including case reports comparing prosthetics rehabilitations with zirconia and titanium abutments upto 3 years of follow-up as well as the factors that should be considered on implant's abutment selection. Metallic abutments can provide grayish color when in contact with thin soft tissues which may lead the implant prosthetic treatment to failure. In this context, the abutments of zirconia stand out because there is an excellent linking between esthetics and the health of peri-implant soft tissues. A consult of the published researches was made on the PubMed database from 2000 to September 2012. The including criteria were: literature reviews, clinical studies and case reports in English that focused on the response of the soft tissue in contact with zirconia implant abutments. The studies that were not in English and did not match the tackled issue were excluded. A total of 32 articles were found. According to the search strategy, just 16 articles were selected for this review. Three studies affirmed that zirconia abutments have an excellent soft tissue response; one study showed increased gingival recession with zirconia abutments and nine studies do not stand out any difference on biological behavior between titanium and zirconia abutments. Three studies affirmed that zirconia abutments provide natural gingival appearance, anatomic contour and greater esthetics. The use of zirconia abutments is recommended for anterior regions because of their greater optical properties and esthetic results and more studies should be performed and analyzed longitudinally regarding their biological response. The zirconia abutments have been established to be essential in order to achieve great esthetic results in cases of thin peri-implant soft tissues and in regions where the three-dimensional placement of implants is more superficial.
Resumo:
This work aimed to analyze clinically and histologically the allogen bone graft behavior at 6 and 9 months. A leukoderm, female, 55 years old patient sought dental care for oral rehabilitation with dental implants and implant supported fixed prosthesis in the maxilla. Bilateral sinus lifting procedure were performed in a same patient, the analysis were made after 6 and 9 months, respectively. At 6 months, there was lack of a better bone remodeling in the region, associated to the presence of fibrous connective tissue within the collected tissue, showing us that this is not the best stage of tissue maturation to place dental implants. The 9 months period showed an improvement, with a more organized bone tissue surrounding particles of homogenous bone, what possibly had increased implant stability at the time of surgery. There is no doubt about the increase of clinical applications of FFBA, but there are no studies available regarding the standardization of time to load implants inserted in allografts. So papers with long-term monitoring are necessary to eliminate questions that still remain to be answered.
Resumo:
Objective. To describe women behavior regarding birth control and analyze if such behavior has any cultural influence. Methodology. Qualitative study in which patients were women who were waiting for their family health program consult in three health units of the city Ilah Comprida in Sao Paulo, Brazil. Data were collected during October and November of 2007, the interview was used as source of information, subsequently they were subjected to the content analysis technique. Results. Women are responsible for birth control; they consider there are difficulties with birth control especially due to inefficient information about methods of contraception and family influence over this adopted behavior. Conclusion. Birth control is influenced by cultural models, moral, social and religious values related with the exercise of sexuality.