50 resultados para cemented hip


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: The aim of this study was to evaluate the influence of ultrasound during the removal of posts cemented with either zinc phosphate cement, glass ionomer cement or resin cement. Methodology: Eighty-four single-rooted teeth were prepared and after cementation of cast posts, they were randomly divided into six groups of 14. Groups 1, 2 and 3 did not receive ultrasonic vibration, whilst groups 4, 5 and 6 received ultrasonic vibration for 10 min. The force necessary for post removal was determined using a universal testing machine. Results were statistically analysed using ANOVA and Tukey tests (5%). Results: The application of ultrasonic vibration reduced the retention provided by zinc phosphate and glass ionomer cements by 39% and 33%, respectively. Conclusions: A statistically significant reduction in the force necessary to remove posts cemented with zinc phosphate and glass ionomer cements occurred following application of ultrasound. The application of ultrasonic vibration did not influence the retention of cast posts cemented with resin cement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the fracture resistance of ceramic plates cemented to dentin as a function of the resin cement film thickness. Materials and Methods: Ceramic plates (1 and 2 mm thicknesses) were cemented to bovine dentin using resin composite cement. The film thicknesses used were approximately 100, 200, and 300 μm. Noncemented ceramic plates were used as control. Fracture loads (N) were obtained by compressing a steel indenter in the center of the ceramic plates. ANOVA and Tukey tests (α = 0.05) were used for each ceramic thickness to compare fracture loads among resin cement films used. Results: Mean fracture load (N) for 1-mm ceramic plates were: control - 26 (7); 100 μm - 743 (150); 200 μm - 865 (105); 300 μm - 982 (226). Test groups were significantly different from the control group; there was a statistical difference in fracture load between groups with 100 and 300 μm film thicknesses (p < 0.01). Mean fracture load for 2-mm ceramic plates were: control - 214 (111); 100 μm - 1096 (341); 200 μm - 1067 (226); 300 μm - 1351 (269). Tested groups were also significantly different from the control group (p < 0.01). No statistical difference was shown among different film thicknesses. Conclusions: Unluted specimens presented significantly lower fracture resistance than luted specimens. Higher cement film thickness resulted in increased fracture resistance for the 1-mm ceramic plates. Film thickness did not influence the fracture resistance of 2-mm porcelain plates. Copyright © 2007 by The American College of Prosthodontists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several studies have reported the benefits of sonic and/or ultrasonic instrumentation for root debridement, with most of them focusing on changes in periodontal clinical parameters. The present study investigated possible alterations in the tensile bond strength of crowns cemented with zinc phosphate cement to natural teeth after ultrasonic instrumentation. Forty recently extracted intact human third molars were selected, cleaned and stored in physiologic serum at 4°C. They received standard preparations, at a 16° convergence angle, and AgPd alloy crowns. The crowns were cemented with zinc phosphate cement and then divided into four groups of 10 teeth each. Each group was then subdivided into two subgroups, with one of the subgroups being submitted to 5,000 thermal cycles ranging from 55 ± 2 to 5 ± 2°C, while the other was not. Each group was submitted to ultrasonic instrumentation for different periods of time: group 1 - 0 min (control), group 2 - 5 min, group 3 - 10 min, and group 4 - 15 min. Tensile bond strength tests were performed with an Instron testing machine (model 4310). Statistical analysis was performed using ANOVA and Tukey's test at the 5% level of significance. A significant reduction in the tensile bond strength of crowns cemented with zinc phosphate and submitted to thermal cycles was observed at 15 min (196.75 N versus 0 min = 452.01 N, 5 min = 444.23 N and 10 min = 470.85 N). Thermal cycling and ultrasonic instrumentation for 15 min caused a significant reduction in tensile bond strength (p < .05).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The literature indicated that the majority of professional ballet dancers present static and active dynamic range of motion difference between left and right lower limbs, however, no previous study focused this difference in non-professional ballet dancers. In this study we aimed to evaluate active movements of the hip in non-professional classical dancers.Methods: We evaluated 10 non professional ballet dancers (16-23 years old). We measured the active range of motion and flexibility through Well Banks. We compared active range of motion between left and right sides (hip flexion and abduction) and performed correlation between active movements and flexibility.Results: There was a small difference between the right and left sides of the hip in relation to the movements of flexion and abduction, which suggest the dominant side of the subjects, however, there was no statistical significance. Bank of Wells test revealed statistical difference only between the 1st and the 3rd measurement. There was no correlation between the movements of the hip (abduction and flexion, right and left sides) with the three test measurements of the bank of Wells.Conclusion: There is no imbalance between the sides of the hip with respect to active abduction and flexion movements in non-professional ballet dancers. © 2011 Valenti et al; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Body size is directly related to the productive and reproductive performance of beef cattle raised under free-range conditions. In an attempt to better plan selection criteria, avoiding extremes in body size, this study estimated the heritabilities and genetic correlations of yearling hip height (YH) and mature hip height (MH) with selection indices obtained at weaning (WI) and yearling (YI) and mature weight (MW). Data from 102,373 Nelore animals born between 1984 and 2010, which belong to 263 farms that participate in genetic evaluation programmes of beef cattle conducted in Brazil and Paraguay, were used. The (co)variance components and genetic parameters were estimated by Bayesian inference in multi-trait analysis using an animal model. The mean heritabilities for YH, MH and MW were 0. 56 ± 0. 06, 0. 47 ± 0. 02 and 0. 42 ± 0. 02, respectively. The genetic correlation of YH with WI (0. 13 ± 0. 01) and YI (0. 11 ± 0. 01) was practically zero, whereas a higher correlation was observed with MW (0. 22 ± 0. 03). Positive genetic correlations of medium magnitude were estimated between MH and WI and YI (0. 23 ± 0. 01 and 0. 43 ± 0. 02, respectively). On the other hand, a high genetic correlation (0. 68 ± 0. 03) was observed between the indicator traits of mature body size (MH and MW). Considering the top 20 % of sire (896 sires) in terms of breeding values for the yearling index, the rank sire correlations between breeding values for MH and MW was 0. 62. In general, the results indicate that selection based on WI and YI should not lead to important changes in YH. However, an undesired correlated response in mature cow height is expected, particularly when selection is performed using YI. Therefore, changes in the body structure of Nelore females can be obtained when MH and MW is used as a selection criterion for cows. © 2012 Institute of Plant Genetics, Polish Academy of Sciences, Poznan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated kinematic patterns in clinically normal German Shepherd dogs (GSDs) compared to those with hip dysplasia and with no clinical signs of lameness. Two groups of GSDs, including 10 clinically healthy dogs (G1) and 10 with hip dysplasia (G2), were trotted on a treadmill at a constant speed. Kinematic data were collected by a 3-camera system and analysed by a motion-analysis program. Flexion and extension joint angles and angular velocities were determined for the shoulder, elbow, carpal, hip, stifle, and tarsal joints.Within each group, the differences between the right and left limbs in all kinematic variables were not significant. Minimum angle, angular displacement and minimum angular velocity did not differ between groups. Significant differences were observed in the maximum angular velocity and maximum angle of the hip joint (dysplastic. >. healthy), and in the maximum angular velocity of the carpal joint (healthy. >. dysplastic). It was concluded that, when trotting on a treadmill, dysplastic dogs with no signs of lameness may present joint kinematic alterations in the hind as well as the forelimbs. © 2012 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This study evaluated the reliability and failure modes of implants with a microthreaded or smooth design at the crestal region, restored with screwed or cemented crowns. The postulated null hypothesis was that the presence of microthreads in the implant cervical region would not result in different reliability and strength to failure than smooth design, regardless of fixation method, when subjected to step-stress accelerated life-testing (SSALT) in water. Materials and methods: Eighty four dental implants (3.3 × 10 mm) were divided into four groups (n = 21) according to implant macrogeometric design at the crestal region and crown fixation method: Microthreads Screwed (MS); Smooth Screwed (SS); Microthreads Cemented (MC), and Smooth Cemented (SC). The abutments were torqued to the implants and standardized maxillary central incisor metallic crowns were cemented (MC, SC) or screwed (MS, SS) and subjected to SSALT in water. The probability of failure versus cycles (90% two-sided confidence intervals) was calculated and plotted using a power law relationship for damage accumulation. Reliability for a mission of 50,000 cycles at 150 N (90% 2-sided confidence intervals) was calculated. Differences between final failure loads during fatigue for each group were assessed by Kruskal-Wallis along with Benferroni's post hoc tests. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The Beta (β) value (confidence interval range) derived from use level probability Weibull calculation of 1.30 (0.76-2.22), 1.17 (0.70-1.96), 1.12 (0.71-1.76), and 0.52 (0.30-0.89) for groups MC, SC, MS, and SS respectively, indicated that fatigue was an accelerating factor for all groups, except for SS. The calculated reliability was higher for SC (99%) compared to MC (87%). No difference was observed between screwed restorations (MS - 29%, SS - 43%). Failure involved abutment screw fracture for all groups. The cemented groups (MC, SC) presented more abutment and implant fractures. Significantly higher load to fracture values were observed for SC and MC relative to MS and SS (P < 0.001). Conclusion: Since reliability and strength to failure was higher for SC than for MC, our postulated null hypothesis was rejected. © 2012 John Wiley & Sons A/S.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aim of this study is to evaluate the serum activity of metalloproteinases (MMPs) -2 and -9 as predictors of pressure ulcer (PU), gait status and mortality 6 months after hip fracture. Methods: Eighty-seven patients over the age of 65 admitted to the orthopedic unit from January to December 2010 with hip fracture were prospectively evaluated. Upon admission, patient demographic information, including age, gender and concomitant diseases, was recorded. Blood samples were taken for analysis of MMP -2 and -9 activity by gel zymography and for biochemical examination within the first 72 hours of the patient's admission, after clinical stabilization. The fracture pattern (neck, trochanteric or subtrochanteric), time from admission to surgery, surgery duration and length of hospital stay were also recorded. Results: Two patients were excluded due to the presence of pathological fractures (related to cancer), and three patients were excluded due to the presence of PU before admission. Eighty-two patients, with a mean age of 80.4 ± 7.3 years, were included in the analysis. Among these patients, 75.6% were female, 59.8% had PU, and 13.4% died 6 months after hip fracture. All patients underwent hip fracture repair. In a univariate analysis, there were no differences in serum MMP activity between hip fracture patients with or without PU. In addition, the multiple logistic regression analysis models, which were adjusted by age, gender, length of hospital stay and C-reactive protein, showed that the pro-MMP-9 complexed with neutrophil gelatinase-associated lipocalin form (130 kDa) was associated with gait status recovery 6 months after hip fracture. Conclusions: In conclusion, serum pro-MMP-9 is a predictor of gait status recovery 6 months after hip fracture. © 2013 Gumieiro et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effects of different light-curing units and resin cement curing types on the bond durability of a feldspathic ceramic bonded to dentin. The crowns of 40 human molars were sectioned, exposing the dentin. Forty ceramic blocks of VITA VM7 were produced according to the manufacturer's recommendations. The ceramic surface was etched with 10% hydrofluoric acid/60s and silanized. The dentin was treated with37% phosphoric acid/15s, and the adhesive was applied. The ceramic blocks were divided and cemented to dentin according to resin cement/RC curing type(dual-and photocured), light-curing unit (halogen light/QTH and LED), and storage conditions (dry and storage/150 days + 12,000 cycles/thermocycling). All blocks were stored in distilled water (37°C/24h) and sectioned (n = 10): G1-QTH + RC Photo, G2-QTH + RC Dual, G3-LED + RC Photo, G4-LED + RC Dual. Groups G5, G6, G7, and G8 were obtained exactly as G1 through G4, respectively, and then stored and thermocycled. Microtensile bond strength tests were performed (EMIC), and data were statistically analyzed by ANOVA and Tukey's test (5%). The bond strength values (MPa) were: G1-12.95 (6.40)ab; G2-12.02 (4.59)ab; G3-13.09 (5.62)ab; G4-15.96 (6.32)a; G5-6.22 (5.90)c; G6-9.48 (5.99)bc; G7-12.78 (11.30)ab; and G8-8.34 (5.98)bc. The same superscript letters indicate no significant differences. Different light-curing units affected the bond strength betweenceramic cemented to dentin when the photocured cement was used, and only after aging (LED>QTH). There was no difference between the effects of dual-and photo-cured resin-luting agents on the microtensile bond strength of the cement used in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the Mini Nutritional Assessment (MNA), the Nutritional Risk Screening (NRS) 2002 and the American Society of Anesthesiologists Physical Status Score (ASA) as predictors of gait status and mortality 6 months after hip fracture. A total of eighty-eight consecutive patients over the age of 65 years with hip fracture admitted to an orthopaedic unit were prospectively evaluated. Within the first 72 h of admission, each patient's characteristics were recorded, and the MNA, the NRS 2002 and the ASA were performed. Gait status and mortality were evaluated 6 months after hip fracture. Of the total patients, two were excluded because of pathological fractures. The remaining eighty-six patients (aged 80·2 (sd 7·3) years) were studied. Among these patients 76·7 % were female, 69·8 % walked with or without support and 12·8 % died 6 months after the fracture. In a multivariate analysis, only the MNA was associated with gait status 6 months after hip fracture (OR 0·773, 95 % CI 0·663, 0·901; P= 0·001). In the Cox regression model, only the MNA was associated with mortality 6 months after hip fracture (hazard ratio 0·869, 95 % CI 0·757, 0·998; P= 0·04). In conclusion, the MNA best predicts gait status and mortality 6 months after hip fracture. These results suggest that the MNA should be included in the clinical stratification of patients with hip fracture to identify and treat malnutrition in order to improve the outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Ciências Sociais - FFC

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)