142 resultados para calibração
Resumo:
To perform the quality control of various industries like: petrochemical, nuclear, aerospace, steel, shipbuilding, pulp and paper, and inspection of welded products, castings, forgings, rolled products, among others, used the method of Non-Destructive Testing (NDT). The method is based on the physical properties of the material, so selecting a procedure more appropriate. The company Inter-Metro Serviços Especiais Ltda., with its cutting-edge laboratory, dedicated to the implementation of calibration services and measurement equipment for industrial, medical, occupational safety and Non-Destructive Testing (NDT). It has a trained team, providing guidance and providing support for improving procedures for testing and measuring
Resumo:
A Dosímetria Termoluminescente (TLD) é uma ferramenta extremamente versátil para a avaliação da dose absorvida por tecidos humanos, devido à interação dos mesmos com a radiação ionizante. As características termoluminescentes (TL) do fluoreto de lítio (LiF) foram estudadas extensivamente primeiramente por apresentar número atômico muito próximo ao do tecido humano e, portanto, conseguir quantificar com fidelidade a radiação recebida na ordem de μGy (micro Gray) a kGy (kilo Gray) . Foram abordados os princípios físicos envolvido no procedimento de calibração e tratamento dos dosímetros (total de 224 pastilhas), os quais foram separados, após tratamento, em 75 grupos. Este trabalho foi de suma importância na aplicação dos conceitos físicos abordados durante a formação da graduação no curso de Bacharelado em Física Médica, e pode auxiliar em projetos, em andamento, junto ao grupo de pesquisa de Física Aplicada ao Radiodiagnóstico
Resumo:
As normas nacionais e internacionais prevêem que a manutenção dos níveis de radiação deve estar abaixo do permitido. Sendo assim, a ICRP [1] (International Commission on Radiological Protection) exige métodos de otimização para garantir que o público esteja exposto aos menores níveis de radiação possíveis. Como método de otimização, aproximações teóricas e semi-empiricas podem realizar uma determinação do espectro de raios-X, sendo fundamental para o diagnóstico de energia, estimando a dose de radiações em pacientes e formulando modelos de blindagem. Métodos adequados de radioproteção foram desenvolvidos na física médica como a medicina nuclear, a radioterapia e a radiologia diagnóstica. Um dos métodos semi-empiricos utilizados é o modelo de TBC que é capaz de reproduzir e calcular os espectros gerados pelo anodo de tungstênio. Com o modelo de TBC modificado é possível também obedecer às exigências das barreiras protetoras presentes na radiologia, levando em conta a forma de onda arbitrária e a filtração adicional na geração do espectro não presente no modelo original. Além disso, realiza-se a calibração do espectro gerado para que o modelo de TBC represente a quantidade e comportamento de radiações típicas. Dessa forma, realiza-se uma revisão do modelo de TBC implementando-o ao programa matemático Matlab e comparando-o com os resultados adquiridos pelo Código MCNP-5 no Método de Monte Carlo. Os resultados encontrados são bastante satisfatórios, tanto em termos quantitativos quanto qualitativos dos feixes. Para a calibração, desenvolve-se uma análise dos espectros gerados pelo TBC Modificado aplicado ao programa Mathcad e Matlab sob as mesmas condições. Os espectros gerados apresentam o mesmo comportamento, diferindo em até 12% nos valores encontrados para camadas semi-redutoras, coeficiente de homogeneidade e energia efetiva
Resumo:
The sources of betatherapy for clinical use in Brazil are, the vast majority of strontium-90, radioactive element that is not produced in the country, and therefore requires importation of international laboratories accredited by the International Atomic Energy Agency (IAEA).The use of these resources is always limited the crediting of characteristic values supplied by the manufacturer tables that provide the nominal value of activity and dose distribution to determine the irradiation time of the injury. The Institute of Nuclear Energy Research (IPEN / CNEN-SP) has recently researching the emission profile of these types of radiation sources, and some jobs are being developed with ionization chambers extrapolation for the purpose of standardizing a systematic calibration sources betatherapy. Other studies using parallel measures dosimeters (TLD's) and simulations with the Monte Carlo method. Radiological films have also been used in studies of applicators dosimetric analysis of strontium-90. This paper seeks to analyze the different methods for calibration of applicators betatherapy, already consolidated in studies by examining the advantages and disadvantages of each procedure
Resumo:
Pós-graduação em Agronomia (Produção Vegetal) - FCAV
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper presents a proposal for the automation of the camera calibration process, locating and measuring image points in coded targets with sub-pixel precision. This automatic technique helps minimize localization errors, regardless of camera orientation and image scale. To develop this technique, several types of coded targets were analyzed and the ARUCO type was chosen due to its simplicity, ability to represent up to 1024 different targets and availability of source code implemented with the OpenCV library. ARUCO targets were generated and two calibration sheets were assembled to be used for the acquisition of images for camera calibration. The developed software can locate targets in the acquired images and it automatically extracts the coordinates of the four corners with sub-pixel accuracy. Experiments were conducted with real data showing that the targets are correctly identified unless excessive noise or fragmentation occurs mainly in the outer target square. The results with the calibration of a low cost camera showed that the process works and that the measurement accuracy of the corners achieves sub-pixel precision.
Resumo:
The tractors are the main potency source, for the traction of tillage equipments and their use are increasing more and more in Brazilian agriculture. In spite of the great technological progress the increase of the number of agricultural tractors brought positive aspects and some negative, among these last ones it stands out the appearance of a new source of work accidents, which importance is given by the physical damages caused to the operator. Therefore the objective of this work was to project and develop an inclinometer, which indicates the inclination of the land, as safety sensor for agricultural tractors to avoid lateral hollovers, through a resonant sign, for the operator and the machine preservation. The built and evaluated inclinometer showed to be efficient for inclination indication of different areas during field operations with agricultural tractors, small angle oscillation and enough answer time to help operators to take decisions in imminence situation of lateral machine hollovers.
Resumo:
This study aimed to establish a calibration model of a TDR equipment to determinate thewood moisture of Grevillea robusta (Cunn.). It was selected alleatory, 11 logs of Grevillea robusta (Cunn.), it was dried in a regulate electric greenhouse at 40o C. During the dry process, the moisture was determinate, periodically and systematically by gravimetric and TDR methods. Through the gravimetric method, moisture vary from 125,88% to 6,62% while the TDR method, the variation was from 119,83% to 5,79%. The best model adjusted to the wood moisture in the determination of the function of relative dielectric constant, using this technique, was the exponential 50,20 132,72 140,27 K U e − = − ⋅ , with a R2 = 0,96, with indicator of trust or performance 0,97 they were classified as very good, according to Camargo and Sentelhas (1997). The correlation between the gravimetric method (reference) and TDR, showed to be equivalent for both methodologies. It was concluded that the TDR can be used to the determination of wood moisture of Grevillea robusta (Cunn.), in a precise and fast way, once it was established it calibration.
Resumo:
O objetivo do trabalho é desenvolver um sistema informático de digitalização e processamento de actinogramas baseado em técnicas de Processamento de Imagens Digitais e comparar com o sistema tradicional de medidas. Os actinogramas foram fornecidos pela Estação Meteorológica de Botucatu (FCA/UNESP). As análises preliminares indicam um desempenho satisfatório do software proposto, gerando medidas na mesma ordem de grandeza do método de referência para partição diária. O software proposto pertence a um projeto que se encontra ainda em andamento, onde rotinas de técnicas diversas continuam sendo implementadas no reconhecimento da curva de interesse para melhorar a qualidade do processamento das informações gráficas dos actinogramas. Os actinogramas estão em fase de digitalização para que o software possa ser testado com uma base de dados mais consistente, onde poderão ser identificados tendências temporais dos dados resultantes da aplicação das técnicas de Processamento de Imagens Digitais no monitoramento da radiação solar por actinógrafos.
Resumo:
A utilização correta de pneus em tratores, tanto em relação ao seu tipo quanto à calibração de sua pressão interna, e a lastragem ideal para cada condição de carga são fatores que influem significativamente no desempenho do trator. Esta pesquisa teve como objetivo comparar o desempenho de um trator equipado com pneus radiais e com pneus diagonais, para três condições de lastragem líquida (0%, 40% e 75% de água), em três condições superficiais de um Nitossolo Vermelho distrófico (superfície firme, preparada e com cobertura vegetal de resto de milho) e em três velocidades teóricas de deslocamento (4 km h-1, 5 km h-1 e 7 km h-1), informadas no painel do trator, correspondendo às marchas B1, B2 e C1. O melhor desempenho do trator, equipado com pneu diagonal, ocorreu na condição de 75% de água nos pneus, apresentando maior velocidade de deslocamento, menor patinhagem do trator, menor consumo horário de combustível e gerando maior potência na barra de tração. Com pneus radiais, o melhor desempenho do trator ocorreu na condição de 40% de água nos pneus, proporcionando maiores velocidades de deslocamento do trator, menores patinhagens, menores consumos, horário e específico de combustível, e maiores potência e rendimento na barra de tração.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objetivou-se com o presente trabalho, estabelecer a relação entre os pigmentos fotossintéticos extraídos em DMSO e as leituras obtidas no clorofilômetro portátil ClorofiLOG® 1030, gerando modelos matemáticos capazes de predizer os teores de clorofila e de carotenóides em folhas de mamoneira. O trabalho foi conduzido na Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA) Algodão, situada em Campina Grande, Estado da Paraíba, em outubro de 2010. Para a análise indireta, foi utilizado um equipamento portátil, sendo realizada a leitura em discos foliares com diferentes tonalidades de verde, sendo feita, nesses mesmos discos, a determinação da clorofila pelo método clássico. Para a extração da clorofila, utilizaram-se 5 mL de dimetilsulfóxido (DMSO), a qual foi mantida em banho-maria a 70ºC, por 30 minutos, e retirou-se 3 mL da alíquota para leitura em espectrofotômetro nos comprimentos de onda de 470, 646 e 663 nm. Os dados foram submetidos à análise da variância e regressão polinomial. A leitura obtida no clorofilômetro portátil foi a variável dependente, e os pigmentos fotossintéticos determinados pelo método clássico foi a variável independente. Os resultados indicaram que o clorofilômetro portátil ClorofiLOG® 1030, associado a modelos matemáticos, permitiu estimar a concentração dos pigmentos fotossintéticos, exceto a clorofila b, com alta precisão, com economia de tempo e com reagentes normalmente utilizados nos procedimentos convencionais.
Resumo:
Várias técnicas têm sido desenvolvidas para se obter o calor específico de sólidos e líquidos, incluindo a construção de experimentos de baixo custo para o ensino médio. Neste trabalho propomos uma maneira simples de se obter o calor específico de sólidos e líquidos. Por meio de curvas de calibração de resfriamento podemos estimar graficamente a perda de calor do sistema para sua vizinhança, e medir o calor específico do alumínio. Esta aproximação permite introduzir uma discussão sobre o processo dinâmico da troca de calor entre dos corpos.