48 resultados para borehole carbon correction factor (avogadro units)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The land use conservation planning requires knowledge of the soil characteristics, natural susceptibility to erosion and the soil loss limit. In this context, the objectives of this study were to perform a detailed soil survey of Ribeirão das Perobas watershed, located in Santa Cruz do Rio Pardo, São Paulo State and to determine and map the erodibility and soil loss tolerance of the soil classes found in the survey. The following techniques were used to perform the detailed soil survey: photopedology, field sampling, physical analysis, chemical analysis, and morphological description of the soil samples and profiles. The erodibility was determined by the methods described by Denardin (1990) and Mannigel et al. (2002), and the determination of soil loss tolerance followed the methodology of Mannigel et al. (2002). The results of erodibility determined by the methodology of Denardin (1990) were not discrepant and they did not distinguish soils that are known to have different susceptibility to erosion., w\Whereas, using the methodology of Mannigel et al. (2002), very high or very low erodibility values were observed in soils with extreme contents of sand silt or clay. The most influent variable to the soil loss tolerance results was the correction factor for the textural gradient of clay between soil horizons.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

This work presents a new high power factor three-phase rectifier based on a Y-connected differential autotransformer with reduced kVA and 18-pulse input current followed by three DC-DC boost converters. The topology provides a regulated output voltage and natural three-phase input power factor correction. The lowest input current harmonic components are the 17th and the 19th. Three boost converters, with constant input currents and regulated parallel connected output voltages are used to process 4kW each one. Analytical results from Fourier analyses of winding currents and the vector diagram of winding voltages are presented. Simulation results to verify the proposed concept and experimental results are shown in the paper.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Tillage stimulates soil carbon (C) losses by increasing aeration, changing temperature and moisture conditions, and thus favoring microbial decomposition. In addition, soil aggregate disruption by tillage exposes once protected organic matter to decomposition. We propose a model to explain carbon dioxide (CO2) emission after tillage as a function of the no-till emission plus a correction due to the tillage disturbance. The model assumes that C in the readily decomposable organic matter follows a first-order reaction kinetics equation as: dC(sail)(t)/dt = -kC(soil)(t) and that soil C-CO2 emission is proportional to the C decay rate in soil, where C-soil(t) is the available labile soil C (g m(-2)) at any time (t). Emissions are modeled in terms soil C available to decomposition in the tilled and non-tilled plots, and a relationship is derived between no-till (F-NT) and tilled (F-Gamma) fluxes, which is: F-T = a1F(NT)e(-a2t), where t is time after tillage. Predicted and observed fluxes showed good agreement based on determination coefficient (R-2), index of agreement and model efficiency, with R-2 as high as 0.97. The two parameters included in the model are related to the difference between the decay constant (k factor) of tilled and no-till plots (a(2)) and also to the amount of labile carbon added to the readily decomposable soil organic matter due to tillage (a,). These two parameters were estimated in the model ranging from 1.27 and 2.60 (a(1)) and - 1.52 x 10(-2) and 2.2 x 10(-2) day(-1) (a(2)). The advantage is that temporal variability of tillage-induced emissions can be described by only one analytical function that includes the no-till emission plus an exponential term modulated by tillage and environmentally dependent parameters. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper introduces novel zero-current-switching (ZCS) pulsewidth-modulated (PWM) preregulators based on a new soft-commutation cell, suitable for insulated gate bipolar transistor applications. The active switches in these proposed rectifiers turn on in zero current and turn off in zero current-zero voltage. In addition, the diodes turn on in zero voltage and their reverse-recovery effects over the active switches are negligible. Moreover, based on the proposed cell, an entire family of de-to-de ZCS-PWM converters can be generated, providing conditions to obtain naturally isolated converters, for example, derived buck-boost, Sepic. and Zeta converters. The novel ac-to-dc ZCS-PWM boost and Zeta preregulators are presented in order to verify the operation of this soft-commutation cell, In order to minimize the harmonic contents of the input current, increasing the ac power factor, the average-current-mode control is used, obtaining preregulators with ac power factor near unity and high efficiency at wide load range. The principle of operation, theoretical analysis, design example, and experimental results from test units for the novel preregulators are presented. The new boost preregulator was designed to nominal values of 1.6 kW output power, 220 V(rms) input voltage, 400 V(dc) output voltage, and operating at 20 kHz. The measured efficiency and power factor of the new ZCS-PWM boost preregulator were 96.7% and 0,99, respectively, with an input current total harmonic distortion (THD) equal to 3.42% for an input voltage with THD equal to 1.61%, at rated load, the new ZCS-PWM Zeta preregulator was designed to voltage step-down operation, and the experimental results were obtained from a laboratory prototype rated at 500 W, 220 V(rm), input voltage, 110 V(dc) output voltage, and operating at 50 kHz. The measured efficiency of the new ZCS-PWM Zeta preregulator is approximately 96.9% and the input power factor is 0.98, with an input current THD equal to 19.07% while the input voltage THD is equal to 1.96%, at rated load.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a new single-phase interleaved high power factor boost pre-regulator operating in critical conduction mode, where the switches and boost diode performing zero-current commutations during its turn-off, eliminating the disadvantages related to the reverse recovery losses and electromagnetic interference problems of the boost diode, when operating in the continuous conduction mode. The interleaving technique is applied in the power cell, providing a significant input current ripple reduction in comparison to discontinuous mode of operation, due to its input current continuous conduction operation. This paper presents a complete modeling for the converter operating in critical conduction mode, resulting in an improved design procedure for interleaved techniques with high input power factor, a complete design procedure, and main simulation results from a design example with two interleaved cells rated at 1kW, 400V output voltage and 220V rms input voltage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a novel single-phase high-power-factor (HPF) pulsewidth-modulated (PWM) boost rectifier featuring soft commutation of the active switches at zero current (ZC), It incorporates the most desirable properties of conventional PWM and soft-switching resonant techniques.The input current shaping is achieved with average current mode control and continuous inductor current mode.This new PWM converter provides ZC turn on and turn off of the active switches, and it is suitable for high-power applications employing insulated gate bipolar transistors (IGBT's),The principle of operation, the theoretical analysis, a design example, and experimental results from a laboratory prototype rated at 1600 W with 400-Vdc output voltage are presented. The measured efficiency and the power factor were 96.2% and 0.99%, respectively, with an input current total harmonic distortion (THD) equal to 3.94%, for an input voltage with THD equal to 3.8%, at rated load.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Os solos agrícolas podem atuar como dreno ou fonte de C atmosférico, dependendo do sistema de manejo adotado. Este estudo foi desenvolvido em experimento de longa duração (22 anos), durante o período de 30 dias do outono, com o objetivo de avaliar o impacto de sistemas de preparo de solo (preparo convencional-PC e plantio direto-PD) nas emissões de C-CO2 de um Latossolo Vermelho distrófico, em Cruz Alta, RS. As emissões de C-CO2 do solo foram avaliadas com câmaras dinâmica (Flux Chamber 6400-09, Licor) e estática (com captação em solução alcalina), imediatamente após a colheita da soja. A temperatura e a umidade do solo foram registradas, concomitantemente com as emissões de C-CO2, por meio de sensor de temperatura e TDR manual, respectivamente, integrantes do Licor-6400. Estimou-se que, em 30 dias, uma quantidade equivalente a menos de 30 % do C aportado pelos resíduos de soja foi emitida na forma de C-CO2. As emissões de C-CO2 no solo em PD foram similares às emissões do solo em PC, independentemente do tipo de câmara utilizada. Diferenças entre sistemas de preparo quanto à emissão de C-CO2, avaliadas com a câmara dinâmica, foram verificadas somente a curto prazo (leituras diárias), com o PD apresentando maiores emissões do que o PC no início do período experimental e menores no final. A câmara dinâmica foi mais eficiente do que a estática em captar as alterações das emissões de C-CO2 em função da variação da temperatura e a porosidade preenchida por água (PPA) no solo em PD, as quais explicaram 83 e 62 % das emissões de C-CO2, respectivamente. O fator Q10, que avalia a sensibilidade da emissão de C-CO2 à temperatura do solo, foi estimado em 3,93, indicando alta sensibilidade da atividade microbiana à temperatura do solo durante o outono. As emissões de C-CO2 registradas no solo em PD com a câmara estática foram correlacionadas às da câmara dinâmica, porém com valores subestimados em relação àquela notadamente nos maiores valores de fluxo. em condições de baixa temperatura e PPA, o preparo de solo induziu limitado incremento de emissão de C-CO2.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: A disfunção renal é uma complicação importante no cenário de pós-operatório de cirurgia cardiovascular. Como fatores de risco conhecidos no intraoperatório para o seu desenvolvimento destacam-se a circulação extracorpórea, a hemodiluição, drogas antifibrinolíticos e a transfusão sanguínea. O objetivo deste estudo é identificar os fatores de risco na transfusão de sangue e derivados para o desenvolvimento de disfunção renal em pacientes submetidos à cirurgia cardiovascular. MÉTODOS: Noventa e sete pacientes foram estudados e 84 foram analisados. A amostra foi estratificada em dois grupos, sendo que o incremento de 30% na creatinina sérica no pós-operatório foi considerado para o grupo com disfunção renal (n = 9; 10,71%). O grupo não disfunção renal foi caracterizado pela creatinina sérica, que permaneceu inferior a aumento de 30% no pós-operatório (n = 75; 89,28%). RESULTADOS: Foi observado que a transfusão de plasma fresco congelado no grupo não disfunção renal foi de 2,05 ± 0,78 unidades e 3,80 ± 2,16 unidades no grupo disfunção renal com P= 0,032. CONCLUSÃO: Foi possível associar, nesta série de pacientes, que a transfusão de plasma fresco congelado foi um fator de risco para disfunção renal pós-operatório de cirurgia cardiovascular.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper discusses the inducer effect of corn soluble starch and the individual components (amylose and amylopectin) from corn and potatoes starch for alpha-amylase production by a strain of Rhizopus sp. The following decreasing order in the enzyme production was obtained: corn amylose > potatoes amylose > corn amylopectin > potatoes amylopectin > starch > maltose, coinciding with the ability of the enzyme to release reducing units, except the soluble starch that was more softly hydrolysed. However, when the enzyme action was measured by the iodine binding method, an inverse order of enzyme activity was obtained, that is: amylopectins > starch > amylosis. The results suggest that: a) branched structures in substrate affect the enzyme production; b) corn amylose and corn amylopectin are better inducers than their respectives homologous from potatoes; c) cc-amylase from Rhizopus sp has different action patterns on substrates with straight or branched chains: from the former, it removes only reducing units with lower molecular weight (G1-G3); from the latter it also removes oligosaccharides with higher molecular weight (G5-G6).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the analysis and the design of a peak-current-controlled high-power-factor boost rectifier, with slope compensation, operating at constant frequency. The input current shaping is achieved, with continuous inductor current mode, with no multiplier to generate a current reference. The resulting overall circuitry is very simple, in comparison with the average-current-controlled boost rectifier. Experimental results are presented, taken from a laboratory prototype rated at 370 W and operating at 67 kHz. The measured power factor was 0.99, with a input current THD equal to 5.6%, for an input voltage THD equal to 2.26%.