73 resultados para background traffic


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We review a formalism of superstring quantization with manifest six-dimensional spacetime supersymmetry, and apply it to AdS(3) x S-3 backgrounds with Ramond-Ramond flux. The resulting description is a conformal field theory based on a sigma model whose target space is a certain supergroup SU' (2\2).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fast sequential multi-element determination of Ca, Mg, K, Cu, Fe, Mn and Zn in plant tissues by high-resolution continuum source flame atomic absorption spectrometry is proposed. For this, the main lines for Cu (324.754 nm), Fe (248.327 nm), Mn (279.482 nm) and Zn (213.857 nm) were selected, and the secondary lines for Ca (239.856 nm), Mg (202.582 nm) and K (404.414 nm) were evaluated. The side pixel registration approach was studied to reduce sensitivity and extend the linear working range for Mg by measuring at wings (202.576 nm; 202.577 nm; 202.578 nm; 202.580 nm: 202.585 nm; 202.586 nm: 202.587 nm; 202.588 nm) of the secondary line. The interference caused by NO bands on Zn at 213.857 nm was removed using the least-squares background correction. Using the main lines for Cu, Fe, Mn and Zn, secondary lines for Ca and K, and line wing at 202.588 nm for Mg, and 5 mL min(-1) sample flow-rate, calibration curves in the 0.1-0.5 mg L-1 Cu, 0.5-4.0 mg L-1 Fe, 0.5-4.0 mg L-1 Mn, 0.2-1.0 mg L-1 Zn, 10.0-100.0 mg L-1 Ca, 5.0-40.0 mg L-1 Mg and 50.0-250.0 mg L-1 K ranges were consistently obtained. Accuracy and precision were evaluated after analysis of five plant standard reference materials. Results were in agreement at a 95% confidence level (paired t-test) with certified values. The proposed method was applied to digests of sugar-cane leaves and results were close to those obtained by line-source flame atomic absorption spectrometry. Recoveries of Ca, Mg, K, Cu, Fe, Mn and Zn in the 89-103%, 84-107%, 87-103%, 85-105%, 92-106%, 91-114%, 96-114% intervals, respectively, were obtained. The limits of detection were 0.6 mg L-1 Ca, 0.4 mg L-1 Mg, 0.4 mg L-1 K, 7.7 mu g L-1 Cu, 7.7 mu g L-1 Fe, 1.5 mu g L-1 Mn and 5.9 mu g L-1 Zn. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional do Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lesões fatais em crianças causadas por acidentes de trânsito representam um problema em muitos países. Este estudo analisou a taxa de mortalidade em crianças passageiras de automóveis menores de 10 anos de idade no Brasil, entre 1997 e 2005. Para isso, o número de mortes foi obtido diretamente no banco de dados do Sistema de Informação sobre Mortalidade (SIM) e os dados da população são projeções intercensitárias a partir censo demográfico do Instituto Brasileiro de Geografia e Estatística (IBGE) disponíveis pelo site do DATASUS. Foram calculadas, para os triênios compreendidos no período em estudo, as taxas de mortalidade por acidente de trânsito entre crianças passageiras de automóveis segundo faixa etária (menor que 1 ano, 1 a 4 e 5 a 9) e região geográfica. Os resultados mostraram taxas de mortalidade de 5,68, 7,32 e 6,78 (por 1.000.000), respectivamente, para os períodos 1997-1999, 2000-2002 e 2003-2005 para todo o Brasil. Crianças menores de 1 ano de idade apresentam taxa de mortalidade de 10,18 (por 1,000,000), maior que as observadas para as outras faixas etárias. Para o período 1997-2005, as maiores taxas foram observadas nas regiões Centro-Oeste e Sul, representando, respectivamente, 13,88 e 11,47 (por 1.000.000). Tais resultados mostram a situação de risco da criança em relação a acidentes de trânsito como passageiras de automóveis e contribuem para a elaboração de campanhas educativas de prevenção de lesões.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method has been developed for the direct and simultaneous determination of As, Cu, Mn, Sb, and Se in drinking water by electrothermal atomic absorption spectrometry (ETAAS) using a transversely heated graphite tube atomizer (THGA) with longitudinal Zeeman-effect back- ground correction. The thermal behavior of analytes during the pyrolysis and atomization stages was investigated in 0.028 mol L-1 HNO3, 0.14 mol L-1 HNO3 and 1 + 1 (v/v) diluted water using mixtures of Pd(NO3)(2) + Mg(NO3)(2) as the chemical modifier, With 5 mug Pd + 3 mug Mg as the modifier, the pyrolysis and atomization temperatures of the heating program of the atomizer were fixed at 1400degreesC and 2100degreesC, respectively, and 20 muL of the water sample (sample + 0.28 mol L-1 HNO3, 1 + 1, v/v), dispensed into the graphite tube, analytical curves were established ranging from 5.00 - 50.0 mug L-1 for As, Sb, Se; 10.0 - 100 mug L-1 for Cu; and 20.0 - 200 mug L-1 for Mn. The characteristic masses were around 39 pg As, 17 pg Cu, 60 pg Mn, 43 pg Sb, and 45 pg Se, and the lifetime of the tube was around 500 firings. The limits of detection (LOD) based on integrated absorbance (0.7 mug L-1 As, 0.2 mug L-1 Cu, 0.6 mug L-1 Mn, 0.3 mug L-1 Sb, 0.9 mug L-1 Se) exceeded the requirements of the Brazilian Food Regulations (decree # 310-ANVS from the Health Department), which established the maximum permissible level for As, Cu, Mn, Sb, and Se at 50 mug L-1, 1000 mug L-1, 2000 mug L-1, 5 mug L-1, and 50 mug L-1, respectively. The relative standard deviations (n = 12) were typically < 5.3% for As, < 0.5% for Cu, < 2.1% for Mn, < 11.7% for Sb, and < 9.2% for Se. The recoveries of As, Cu, Mn, Sb, and Se added to the mineral water samples varied from 102-111%, 91-107%, 92-109%, 89-97%, and 101-109%, respectively. Accuracy for the determination of As, Cu, Mu Sb and Se was checked using standard reference materials NIST SRM 1640 - Trace Elements in Natural Water, NIST SRM 1643d - Trace Elements in Water, and 10 mineral water samples. A paired t-test showed that the results were in agreement with the certified values of the standard reference materials at the 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method has been developed for the direct determination of As in sugar by graphite furnace atomic absorption spectrometry with a transversely heated graphite atomizer (end-capped THGA) and longitudinal Zeeman-effect background correction. The thermal behavior of As during the pyrolysis and atomization steps was investigated in sugar solutions containing 0.2% (v/v) HNO3 using Pd, Ni, and a mixture of Pd + Mg as the chemical modifiers. For a 60-muL sugar solution, an aliquot of 8% (m/v) in 0.2% (v/v)HNO3 was dispensed into a pre-heated graphite tube at 70 degreesC. Linear analytical curves were obtained in the 0.25 - 1.50-mug L-1 As range. Using 5 mug Pd and a first pyrolysis step at 600 degreesC assisted by air during 40 s, the formation of a large amount of carbonaceous residue inside the atomizer was avoided. The characteristic mass was calculated as 24 pg As and the lifetime of the graphite tube was around 280 firings. The limit of detection (L.O.D.) based on integrated absorbance was 0.08 mug L-1 (4.8 pg As) and the typical relative standard deviation (n = 12) was 7% for a sugar solution containing 0.5 mug L-1. Recoveries of As added to sugar samples varied from 86 to 98%. The accuracy was checked in the direct analysis of eight sugar samples. A paired t-test showed that the results were in agreement at the 95% confidence level with those obtained for acid-digested sugar samples by GFAAS.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heme is present in all cells, acting as a cofactor in essential metabolic pathways such as respiration and photosynthesis. Moreover, both heme and its degradation products, CO, iron and biliverdin, have been ascribed important signaling roles. However, limited knowledge is available on the intracellular pathways involved in the flux of heme between different cell compartments. The cattle tick Boophilus microplus ingests 100 times its own mass in blood. The digest cells of the midgut endocytose blood components and huge amounts of heme are released during hemoglobin digestion. Most of this heme is detoxified by accumulation into a specialized organelle, the hemosome.We followed the fate of hemoglobin and albumin in primary cultures of digest cells by incubation with hemoglobin and albumin labeled with rhodamine. Uptake of hemoglobin by digest cells was inhibited by unlabeled globin, suggesting the presence of receptor-mediated endocytosis. After endocytosis, hemoglobin was observed inside large digestive vesicles. Albumin was exclusively associated with a population of small acidic vesicles, and an excess of unlabeled albumin did not inhibit its uptake. The intracellular pathway of the heme moiety of hemoglobin was specifically monitored using Palladium-mesoporphyrin IX (Pd-mP) as a fluorescent heme analog. When pulse and chase experiments were performed using digest cells incubated with Pd-mP bound to globin (Pd-mP-globin), strong yellow fluorescence was found in large digestive vesicles 4 h after the pulse. By 8 h, the emission of Pd-mP was red-shifted and more evident in the cytoplasm, and at 12 h most of the fluorescence was concentrated inside the hemosomes and had turned green. After 48 h, the Pd-mP signal was exclusively found in hemosomes. In methanol, Pd-mP showed maximal emission at 550 nm, exhibiting a red-shift to 665 nm when bound to proteins in vitro.The red emission in the cytosol and at the boundary of hemosomes suggests the presence of heme-binding proteins, probably involved in transport of heme to the hemosome. The existence of an intracellular heme shuttle from the digestive vesicle to the hemosome acting as a detoxification mechanism should be regarded as a major adaptation of ticks to a blood-feeding way of life. To our knowledge, this is the first direct observation of intracellular transport of heme in a living eukaryotic cell. A similar approach, using Pd-mP fluorescence, could be applied to study heme intracellular metabolism in other cell types.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider inertial and accelerated Unruh-DeWitt detectors moving in a background thermal bath and calculate their excitation rate. It is shown that for fast moving detectors such a thermal bath does not affect substantially the excitation probability. Our results are discussed in connection with a possible proposal of testing the Unruh effect in high energy particle accelerators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We argue that the minimal chiral background for the two-pion exchange nucleon-nucleon (NN) interaction has nowadays a rather firm conceptual basis, which entitles it to become a standard ingredient of any modern potential. In order to facilitate applications, we present a parametrized version of a configuration space potential derived previously. We than use it to assess the phenomenological contents of some existing NN potentials.