63 resultados para air cooling systems
Resumo:
In this work, experimental results are reported for a small scale cogeneration plant for power and refrigeration purposes. The plant includes a natural gas microturbine and an ammonia/water absorption chiller fired by steam. The system was tested under different turbine loads, steam pressures and chiller outlet temperatures. An evaluation based on the 1st and 2nd Laws of Thermodynamics was also performed. For the ambient temperature around 24°C and microturbine at full load, the plant is able to provide 19 kW of saturated steam at 5.3 bar (161 °C), corresponding to 9.2 kW of refrigeration at -5 °C (COP = 0.44). From a 2nd law point-of-view, it was found that there is an optimal chiller outlet temperature that maximizes the chiller exergetic efficiency. As expected, the microturbine presented the highest irreversibilities, followed by the absorption chiller and the HRSG. In order to reduce the plant exergy destruction, it is recommended a new design for the HRSG and a new insulation for the exhaust pipe. © 2013 Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The use of refrigeration and air conditioning systems is of fundamental importance when it comes to air-conditioning of environments. Also important is the use of electricity for equipments’ operation related to these systems. Due to high cost of charging for this type of energy, factors economy and efficiency occupy key roles among design parameters of a system. One of the ways to get this economy is the use of a technique called thermal storage, or cold storage, which intends to move the required loads during peak time and also their equalizing, so that the energy is transferred from the peak time to non-peak time, thereby reducing the cost of energy consumed. Cold can be stored in the form of ice or ice water. This work aims to perform a technical-economic analysis of a mall located in Vale do Paraíba checking the feasibility of deploying a thermal storage system to achieve an economy in the cost of the energy used by the establishment. Through the parameters measured by the concessionaire of energy we can get the values of energy demand and power consumed, which will serve as basis for calculation for the study. The results obtained allow the development of two alternative proposals to the current configuration, one chosen by the criteria and results presented by technical-economic and energy analysis
Resumo:
Climate change in tropical countries, like Brazil, causes major problems in dairy production due to an increase of heat stress effects. In recent years, milk production in Brazil increased 36.07%. The Southeast region remains a leader in production with herds of high producing Holstein cattle (mostly), which is more susceptible to heat stress. Thermal stress decreases fertility in direct and indirect ways. Conception rates are reduced of 40-60% during cooler months of the year and 10-20% in the warmer months. Negative effects of heat stress involve changes in reproductive hormones, follicular development, oocytes, and embryos, and decreased dry matter intake. Several studies discuss change in reproductive hormones, such as reduction in plasma concentration of GnRH, LH, and oestradiol, which lead to decreased detection of estrus and ovulation. Various methods are being studied to bypass these negative effects and increase the fertility of dairy cows under heat stress. Cooling systems are the most advantageous and can be associated with technologies such as ET and TAI
Resumo:
This paper aims to study the thermal aspects involved in a liquid cooling system for processors, analyzing their competitiveness and efficiency across the fins and fan system usually used by personal computers, because electronic components become more potent and consequently current methods of cooling are becoming ineffective. The liquid cooling system and air cooling system have different heat transfer mechanisms that involve mainly convection and conduction heat transfer modes, and, furthermore, requires an analysis of fluid dynamics, which can evaluate the losses involved in the closed system, consisting in an exchanger heat pipe and water blocks in liquid cooling system or heat sink and turbo-axial fan in the air cooling system
Resumo:
In this work a study about the mechanical properties of the API 5L X70 steel, with or without heat treating, has been made, with the intetion of assess the influence of cooling after the austenitization heat treating by air cooling (normalizing) and a rapid cooling with oil (tempering). This steel is known by high strength and ductility values and it is commonly used in the manufacture of oil pipes. The growing energy demand encouraged the study and manufacture of this material. Although this microalloyed dispense subsequent heat treatings, it was proven that its implementation is very advantageous for this type of application, improving hardness and plastic stability. It was also assessed that the faster the cooling rate is, the better will be these properties