207 resultados para Wheel dressing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To evaluate the healing of experimentally induced chronic periapical lesions in dogs at 30, 75, and 120 days after root canal instrumentation with rotary NiTi files or manual K-files, with or without a calcium hydroxide/1% chlorhexidine paste intracanal dressing.Study design. The second, third, and fourth mandibular premolars and the second and third maxillary premolars of 5 dogs (12 to 18 months of age, weighing 8 to 15 kg) were selected for treatment (a total of 82 root canals). After pulp removal, the root canals were left exposed to the oral cavity for 7 days to allow microbial contamination, after which the root canals were sealed with ZOE cement until periapical lesions were confirmed with radiography. Group I and II teeth were instrumented with manual K-files using the crown-down technique. In group III and IV teeth, NiTi rotary files were used. The apical delta was perforated by using #20 to #30 K-files at the length of the tooth, thus creating a standardized apical opening. The apical stop was enlarged to size 70, with 2.5% sodium hypochlorite irrigation at each file change. Teeth in groups II and IV were dressed with calcium hydroxide (Ca(OH)(2))/1% chlorhexidine (CHX) paste for 15 days before root filling. Group I and III teeth did not receive an intracanal dressing. The access openings of the teeth were permanently restored with silver amalgam condensed on a glass ionomer cement base. Pairs of standardized periapical radiographs were taken at the beginning of the treatment (0 days) and at 30, 75, and 120 days after filling.Results. There was no significant difference in the rate of radiographic healing of the periapical lesions between manual and rotary instrumentation. Radiographs taken at 120 days showed that the treatment with Ca(OH)(2)/1% CHX paste resulted in a significant reduction in mean size of the periapical lesions in comparison to single-session treatment. These findings were also true for histologic observations.Conclusion. The findings support the hypothesis that, regardless of the instrumentation technique (manual or rotary), the use of an intracanal dressing is important in the endodontic treatment of dog's teeth with experimentally induced chronic periapical lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To compare the periapical repair of teeth with periapical lesion following root canal treatment by using a calcium hydroxide-based intracanal dressing for several time periods or filling in a single visit.Study design. After induction of periapical lesions in 4 dogs, the root canals were prepared using 5.25% sodium hypochlorite for irrigation, and animals were separated into 4 experimental groups; in group I, root canals were filled in a single session; in groups II, III, and IV, a calcium hydroxide-based dressing was kept in place for 15, 30, or 180 days, respectively. Root canals from groups I, II, and III were filled with gutta-percha cones and AH Plus sealer. After 180 days, animals were killed and histological sections were stained with hematoxylin-eosin to evaluate periapical repair.Results. Periapical repair was better in groups II, III, and IV (intracanal dressing) compared with group I (single session; P <.05).Conclusion. The use of a calcium hydroxide-based intracanal dressing was important for periapical repair in teeth with periapical lesion. Dressing with calcium hydroxide paste results in better periapical repair than when the root canal is filled in a single-session treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Grinding is a finishing process in machining operations, and the topology of the grinding tool is responsible for producing the desired result on the surface of the machined material The tool topology is modeled in the dressing process and precision is therefore extremely important This study presents a solution in the monitoring of the dressing process, using a digital signal processor (DSP) operating in real time to detect the optimal dressing moment To confirm the monitoring efficiency by DSP, the results were compared with those of a data acquisition system (DAQ) and offline processing The method employed here consisted of analyzing the acoustic emission and electrical power signal by applying the DPO and DPKS parameters The analysis of the results allowed us to conclude that the application of the DPO and DPKS parameters can be substituted by processing of the mean acoustic emission signal, thus reducing the computational effort

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare wild boar (chromosomal number 2n = 36) to phenotypically similar animals of 2n = 37 and 2n = 38 chromosomes (crossbreeds) with respect to live weight, carcass yield, meat yield, fat and weight of inner organs. All animals were born and raised on the same farm and slaughtered at 39 weeks. The final live weight of wild boar 2n = 36 was significantly lower (47.2 kg) as compared to crossbreeds (80.0 kg). Animals 2n = 36 had more carcass yields (65.5%) than 2n = 37 karyotype (64.9%) and 2n = 38 (64.4%). Wild boar had the highest yields for the cuts with bones and boneless cuts compared to crossbreeds. Therefore, variations in karyotype are accompanied by differences in some carcass quantitative traits, i.e., 2n = 36 grow and fatten slower than crossbreeds 2n = 37 and 2n = 38. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to analyse the apical leakage in teeth filled by the lateral condensation technique following medication with calcium hydroxide. One hundred and twenty extracted human teeth were biomechanically prepared by using exclusively reaming motion with files up to #40. Half of the teeth received a calcium hydroxide dressing for 3 days. The medication was removed by irrigation and reaming motion with files #40 up to #70. The teeth were divided in 6 experimental groups, according to the dimension of the utilized instrument. The root canals were filled and posteriorly the teeth were placed into a 2% methylene blue dye solution inside a flask, which was attached to a vacuum pump. Leakage was measured linearly, and the results showed significantly (p<0.01) less leakage in the experimental groups that received calcium hydroxide dressings than in the control groups. The results persisted even after the removal of 300 micrometers of dentin from the root canal dentinal walls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The solutions of a large class of hierarchies of zero-curvature equations that includes Toda- and KdV-type hierarchies are investigated. All these hierarchies are constructed from affine (twisted or untwisted) Kac-Moody algebras g. Their common feature is that they have some special vacuum solutions corresponding to Lax operators lying in some Abelian (up to the central term) subalgebra of g; in some interesting cases such subalgebras are of the Heisenberg type. Using the dressing transformation method, the solutions in the orbit of those vacuum solutions are constructed in a uniform way. Then, the generalized tau-functions for those hierarchies are defined as an alternative set of variables corresponding to certain matrix elements evaluated in the integrable highest-weight representations of g. Such definition of tau-functions applies for any level of the representation, and it is independent of its realization (vertex operator or not). The particular important cases of generalized mKdV and KdV hierarchies as well as the Abelian and non-Abelian affine Toda theories are discussed in detail. © 1997 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work war to study the behavior of the plan tangential grinding process with conventional grinding wheels, under several machining conditions and a selected dressing condition. The analysis of the grinding performance was done regarding the cutting surface wear behavior of the grinding wheel for brittle and ductile steels workpieces. The grinding input parameters, which were, cutting speed, workpiece speed and cutting feed, were chosen based on the grinding machine characteristics. The results discussion emphasized the wear mechanism of the grinding wheel cutting surface and the cutting phenomenology of the grinding process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Grinding is a precision machining process which is widely used in the manufacture of components requiring fine tolerances and smooth surfaces. There are several imput parameters (cutting conditions, cutting fluid and grinding wheel type used, dressing conditions etc.) which can affect the process variables (tangential and normal cutting forces, roughness, grinding temperatures, G ratio, etc.) leading to differences in the roughness, in the surface integrity and in the mechanical strength of the ground component. Consequently, the imput parameters must be controlled in order to insure the workpiece final quality. This paper presents a comparative evaluation of the performance of two types of grinding wheels [a conventional (Al2O3) and a superabrasive (CBN)] when grinding a VC131 steel, by the analysis of specific process variables when varying the cutting conditions. Highest values of G ratio and lowest workpiece roughness was observed when using CBN grinding wheels. This confirms the global trend of replacement of alumina grinding wheels by CBN, when grinding DTG (difficult to grind) materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the behavior of the steel surface grinding process with conventional grinding wheels was studied for various grinding conditions and a fixed dressing condition. The input parameters (wheel speed, workpiece speed, depth of cut), that set up the grinding conditions were determined as a function of the characteristics of the grinding machine. A test bench was established where the grinding power was measured in real time as a function of the volume of material removed. The results showed that in the grinding of fragile steels with a soft wheel and medium grit size, the average power of the cut shows a tendency to increase and become stabilized. The surface roughness of the piece decreased in all the tests and was proportional to the increase in the number of active grits. In tests on the grinding of ductile steels with a soft wheel and fine grit size, the wheel became dull until the moment that the abrasive grits were released from the cut surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to evaluate periapical and apical repair using calcium hydroxide root canal dressings for different lengths of times in teeth with induced chronic periapical lesions. A total of 61 root canals of maxillary and mandibular premolars from 4 dogs were used. After mechanical preparation of the root canals using the crown-down technique, and 5.25% NaOCl as irrigating solution, the apical foramen was enlarged in all cases. A calcium hydroxide root canal dressing was applied. The control group did not receive a root canal dressing. The animals were killed at 7, 15 or 30 days. After histological preparation, serial sections were stained with hematoxylin-eosin and Mallory's trichrome. The best histopathological results occurred at 15 and 30 days, and the worst results occurred at 7 days and in the control group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the high industrial competitiveness, the rigorous laws of environmental protection, the necessary reduction of costs, the mechanical industry sees itself forced to worry more and more with the refinement of your processes and products. In this context, can be mentioned the need to eliminate the roundness errors that appear after the grinding process. This work has the objective of verifying if optimized nozzles for the application of cutting fluid in the grinding process can minimize the formation of the roundness errors and the diametrical wear of grinding wheel in the machining of the steel VC 131 with 60 HRc, when compared to the conventional nozzles. These nozzles were analyzed using two types of grinding wheels and two different cutting fluids. Was verified that the nozzle of 3mm of diameter, integral oil and the CBN grinding wheel, were the best options to obtain smaller roundness errors and the lowest diametrical wears of grinding wheels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to evaluate the distribution of microorganisms in the root canal system (RCS) and periapical lesions of dogs' teeth after rotary instrumentation and placement of different calcium hydroxide [Ca(OH)2]-based intracanal dressings. MATERIALS AND METHODS: Chronic periapical lesions were experimentally induced in 80 premolar roots of four dogs. Instrumentation was undertaken using the ProFile rotary system and irrigation with 5.25% sodium hypochlorite. The following Ca(OH) 2-based pastes were applied for 21 days: group 1 - Calen (n=18); group 2 - Calen+CPMC (n=20); group 3 - Ca(OH)2 p.a. + anaesthetic solution (n=16) and group 4 - Ca(OH)2 p.a.+ 2% chlorhexidine digluconate (n=18). Eight root canals without endodontic treatment constituted the control group. Histological sections were obtained and stained with Brown & Brenn staining technique to evaluate the presence of microorganisms in the main root canal, ramifications of the apical delta and secondary canals, apical cementoplasts, dentinal tubules, areas of cemental resorption and periapical lesions. The results were analyzed statistically by the Mann-Whitney U test (p<0.05). RESULTS: The control group showed the highest prevalence of microorganisms in all sites evaluated. Gram-positive cocci, bacilli and filaments were the most frequent morphotypes. Similar microbial distribution patterns in the RCS and areas of cementum resorption were observed in all groups (p>0.05). The percentage of RCS sites containing microorganisms in groups 1, 2, 3, 4 and control were: 67.6%, 62.5%, 78.2%, 62.0% and 87.6%, respectively. CONCLUSION: In conclusion, the histomicrobiological analysis showed that the rotary instrumentation and the different calcium hydroxide pastes employed did not effectively eliminate the infection from the RCS and periapical lesions. However, several bacteria seen in the histological sections were probably dead or were inactivated by the biomechanical preparation and calcium hydroxide-based intracanal dressing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: Alveolitis is considered a disturbance of the alveolar healing process that is characterized by blood clot disintegration, alveolar wall infection and extreme pain. Several substances have been investigated to improve healing and guarantee postoperative comfort to patients. The aim of this study was to evaluate, microscopically, in rats, the healing process in non-infected tooth sockets, after application of a 10% metronidazole and 2% lidocaine dressing, using lanolin as vehicle and mint as flavoring. METHODS: Forty-five rats (Rattus norvegicus albinus, Wistar) had their right incisor extracted and were randomly assigned to 3 groups (n=15): Group I (control): the sockets were filled with blood clot; Group II: application of adrenaline solution at 1:1 000 with an absorbent paper point during 1 min plus filling of the socket with a 10% metronidazole and 2% lidocaine dressing, with lanolin as vehicle, and mint as flavoring; Group III: filling of the socket with the 10% metronidazole and 2% lidocaine dressing, with lanolin as vehicle and mint as flavoring. After 6, 15 and 28 days postoperatively, 5 animals per group were euthanized with an injectable anesthetic overdose. Histological and statistical analyses were performed. RESULTS: The results showed that the 10% metronidazole and 2% lidocaine dressing with lanolin as vehicle and mint as flavoring yielded similar response as that of the normal repair group and may be used to prevent the onset of alveolitis in those cases in which any predisposing factor is present. CONCLUSIONS: The use of this dressing has shown a good postoperative patient's comfort and does not cause a significant delay in the alveolar healing process.