91 resultados para UMBILICAL VEIN
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A importância do estudo do sangue do cordão umbilical (SCU) tem sido verificada pela presença de células-tronco hematopoéticas no SCU humano. O modelo experimental em cão tem propiciado informações importantes nos transplantes em humanos. Entretanto, apesar da importância do SCU e do modelo experimental em cães, não existem estudos sobre a eletroforese de proteínas séricas do cordão umbilical canino. No presente protocolo experimental, foi feita a colheita de SCU de 20 neonatos caninos, o qual foi utilizado para o fracionamento eletroforético de suas proteínas. Os valores médios absolutos obtidos para proteínas séricas totais, albumina, alfa, beta e gamaglobulinas no sangue do cordão umbilical de cães ao nascimento foram 3,09±0,59; 1,51±0,38; 0,87±0,17; 0,68±0,12 e 0,03±0,01, respectivamente. Todos os resultados apresentaram-se abaixo dos níveis reportados para animais adultos, devido à passagem das proteínas e suas frações ocorrerem principalmente através do colostro e pela imaturidade hepática. em todos os traçados eletroforéticos do SCU de cães, foi observada uma pequena curva entre alfaglobulina 2 e betaglobulina 1, não relatada no soro de cães adultos. Portanto, neste experimento, foram observadas diferenças quantitativas no traçado eletroforético das proteínas séricas do SCU de cães, ao nascimento, diferindo-os, neste particular, de cães em diferentes fases da vida pós-colostral.
Resumo:
O sangue do cordão umbilical humano tem sido crescentemente utilizado como fonte de células-tronco. Os modelos experimentais de células-tronco da medula óssea, em cães, têm propiciado informações importantes para transplantes medulares em humanos. Vários trabalhos citam a influência do tipo de parto nas características do sangue do cordão umbilical (SCU) humano. Entretanto, não existem relatos sobre a colheita do sangue do cordão umbilical de cães. O objetivo deste ensaio é avaliar a influência do tipo de parto na hematologia do cordão umbilical de cães. No presente protocolo experimental, foram estudados 54 fetos de cães, ao final da vida intra-uterina, provenientes de parto normal (n=24) e cesariana (n=30). A colheita de sangue do cordão umbilical foi realizada com seringa de cinco mL contendo solução anticoagulante EDTA (1mg/1mL sangue). em seguida, a contagem global de hemácias, leucócitos, plaquetas, a determinação da concentração de hemoglobina, taxa de hematócrito, os índices eritrocitários foram realizados no contador automático de células. A contagem diferencial de leucócitos foi determinada em esfregaços de SCU corados com May-Grunwald-Giemsa (MGG). Com relação ao eritrograma e ao plaquetograma, não houve diferença significativa entre as amostras obtidas em cesarianas e partos normais. Os valores do leucograma do SCU colhido em partos normais foram superiores àqueles obtidos em cesarianas (P<0,05). Portanto, o tipo de parto influencia os valores hematológicos do cordão umbilical de cães.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: Comparar a eficácia e segurança da profilaxia com heparina de baixo peso molecular (enoxaparina) versus heparina não fracionada (HNF). MÉTODOS: Setenta e cinco pacientes (59 homens e 16 mulheres ), submetidos a amputação maior dos membros inferiores (30 acima do joelho e 45 abaixo do joelho ), foram tratados ao acaso com HNF subcutânea (5,000 IU -2x/dia ) ou enoxaparina subcutânea (40mg/dia ) durante a hospitalização . A profilaxia teve início 12 horas antes da cirurgia ou , em casos emergenciais , no primeiro dia de pós-operatório. RESULTADOS: Os dois grupos de tratamento foram comparáveis em termos de características gerais . A avaliação da TVP foi feita por meio de exame clínico diário e pelo mapeamento dúplex antes e 5-8 dias após a cirurgia . A TVP foi documentada no lado operado em 9,75% dos pacientes tratados com enoxaparina e em 11,76% dos pacientes tratados com HNF (p=0,92) e houve um caso de TVP bilateral em cada grupo . Sangramentos não foram verificados nos 2 grupos . CONCLUSÃO: A enoxaparina e HNF foram igualmente eficientes e seguras para a profilaxia da TVP em pacientes submetidos à amputação de membros inferiores .
Resumo:
Aim. One of the major causes of chronic venous disease is venous reflux, the identification and quantification of which are important for diagnosis. Duplex scanning allows for the detection and quantification of reflux in individual veins. Evaluation of the great saphenous vein in primary varicosis is necessary for its preservation. Objective of the study is to evaluate a possible correlation between the intensity of reflux at the saphenofemoral junction, diameter alterations of the incompetent great saphenous vein and the practical effect of such correlation. Also to compare the clinical severity of the CEAP classification with such parameters.Methods. Three hundred limbs were submitted to duplex evaluation of their insufficient saphenous veins. Vein diameter was measured on five different points. Velocity and flow at reflux peak and reflux time were determined. The saphenous vein's diameters were correlated with velocity, flow and time. The three latter parameters and diameters were compared with clinical severity according to CEAP.Results. Correlation was found between the saphenous vein's diameters, velocity and flow. No correlation was observed between time and diameter in the thigh's upper and middle thirds. When comparing diameter, velocity and flow with CEAP clinical severity classification, an association was observed. The correlation between reflux time with clinical severity was weak.Conclusion. Reflux time is a good parameter for identifying the presence of reflux, but not for quantifying it. Velocity and peak flow were better parameters for evaluating reflux intensity as they were correlated with great saphenous vein alterations, and were associated with the disease's clinical severity. [Int Angiol 2010;29:323-30]
Resumo:
Aim. Superficial thrombophlebitis (ST) ascending the lower limbs is a common disease, which may be associated with deep vein thrombosis (DVT) and pulmonary embolism (PE). The aim of this study was to investigate the prevalence of DVT and PE as complications of ascending ST of the lower limbs in the great saphenous vein (GSV) or SSV (SSV) and probable risk factors.Methods. For this study 60 consecutive patients were enrolled with ascending ST of the GSV or SSV, seen between 2000 and 2003 at a public hospital in Botucatu, SP, Brazil. All patients were assessed clinically, by venous Duplex scanning of the lower limbs to confirm ST and test for DVT, and by means of pulmonary scintigraphy to test for PE.Results. In 13 ST cases (21.67%) there was concomitant DVT and 17 ST patients (28.33%) also had PE. Eleven patients had a clinical status suggestive of DVT, but only in eight of these (61.5%), this clinical diagnosis was confirmed. Fourteen patients had a clinical status suggestive of PE, and this diagnosis was confirmed in six cases (35.30%). ST patients who also had DVT and/or PE were given anticoagulant treatment with heparin and warfarin. None of the variables studied was predictive of DVT or PE (P>0.05). However, the presence of varicose veins reduced the risk of patients having DVT (relative risk=9.09; 95%CI:1.75 - 50.00 and P=0.023).Conclusion. The prevalence rates of PE (28.3%) and DVT (21.6%) were elevated in this sample of ascending ST cases, indicating a need for detailed assessment of patients for signs of these complications, including for therapeutic management decision making. [Int Angiol 2009;28:400-8]
Resumo:
Aim. This study aimed at assessing the accuracy of ultrasound (US) in the diagnosis of recent deep vein thrombosis (DVT) in an experimental study in dogs.Methods. Design: blinded and randomized experimental study. Twenty dogs were randomly divided in two groups: control group (CG) and thrombosis group (TG). US was performed in the pre- and postoperative period. Phlebography was performed immediately prior to the postoperative US. After the second US, a surgery was performed to detect whether thrombus was present or not. US results were compared to those of phlebography and surgical findings.Results. in all dogs, inferior vena cava (IVC) was compressible. The relations of IVC diameter with the aorta were higher (P<0.005) in TG than in CG. Spectral Doppler in spontaneous breathing, tissue harmonic imaging, power Doppler and B flow showed sensitivity, specificity and accuracy of 1. Phlebography presented sensitivity of 90%, specificity of 80% and accuracy of 85%, when compared to surgical finding.Conclusion. For the diagnosis of recent DVT in the experimental model used, venous compressibility proved to be inefficient. The ratio of WC diameter to aorta, when increased, suggests thrombosis. The use of new US technological advances increases accuracy. Phlebography was less accurate than US.
Resumo:
Superficial nerve injuries are very common during varicose vein surgery. In contrast, deep nerve injuries are rare and reported especially when surgery involves the small saphenous vein (SSV). The deep motor nerves most commonly injured are the tibial nerve and the peroneal nerve, which are directly or indirectly affected by extrinsic compression, stretching, or healing process involvement. In this report, two cases of common fibular nerve injury after SSV stripping are described, including treatment used and patient outcomes. Nerve damage mechanisms, anatomy, and prevention strategies are also discussed. In conclusion, fibular nerve damage may occur during SSV stripping. Preventive measures include careful preoperative ultrasonographic investigation of the anatomy of the vein, determining location of the saphenopopliteal joint, and careful dissection far from fibular nerve and restricted to the popliteal fossa.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This pilot study uses concentrations of metals in maternal and cord blood at delivery, in seven selected geographical areas of South Africa, to determine prenatal environmental exposure to toxic metals. Samples of maternal and cord whole blood were analysed for levels of cadmium, mercury, lead, manganese, cobalt, copper, zinc, arsenic and selenium. Levels of some measured metals differed by site, indicating different environmental pollution levels in the regions selected for the study. Mercury levels were elevated in two coastal populations studied (Atlantic and Indian Ocean sites) with mothers from the Atlantic site having the highest median concentration of 1.78 mu g/L ranging from 0.44 to 8.82 mu g/L, which was found to be highly significant (p < 0.001) when compared to other sites, except the Indian Ocean site. The highest concentration of cadmium was measured in maternal blood from the Atlantic site with a median value of 0.25 mu g/L (range 0.05-0.89 mu g/L), and statistical significance of p < 0.032, when compared to all other sites studied, and p < 0.001 and p < 0.004 when compared to rural and industrial sites respectively, confounding factor for elevated cadmium levels was found to be cigarette smoking. Levels of lead were highest in the urban site, with a median value of 32.9 mu g/L (range 16-81.5 mu g/L), and statistically significant when compared with other sites (p < 0.003). Levels of selenium were highest in the Atlantic site reaching statistical significance (p < 0.001). All analysed metals were detected in umbilical cord blood samples and differed between sites, with mercury being highest in the Atlantic site (p < 0.001), lead being highest in the urban site (p < 0.004) and selenium in the Atlantic site (p < 0.001). To the best of our knowledge this pilot investigation is the first study performed in South Africa that measured multiple metals in delivering mothers and umbilical cord blood samples. These results will inform the selection of the geographical sites requiring further investigation in the main study.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)