294 resultados para Tubo em "T" de silicone
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The failure of facial prostheses is caused by limitations in the properties of existing materials, especially flexibility and durability. Therefore, this study evaluated the Shore A hardness of silicone used for fabrication of facial prostheses, Silastic MDX4-4210, according to the influence of storage period, daily disinfection, and 2 types of pigmentation. Thirty specimens were fabricated and divided in 3 groups: colorless, pigmented with makeup, and pigmented with iron oxide. Analysis of results was assessed on a Shore A hardness meter immediately, 6 months, and 1 year after fabrication of specimens, following the guidelines of the American Society for Testing and Materials. The hardness values were statistically analyzed by the Tukey test. The silicone exhibited an increase in hardness with time. However, the hardness was stable from 6 months to 1 year. It was concluded that the silicone is within the values of Shore A hardness reported in the literature, regardless of the storage period, pigmentation, and chemical disinfection.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to evaluate the color stability of a maxillofacial elastomer with the addition of a nanoparticle pigment and/or an opacifier submitted to chemical disinfection and artificial aging. Specimens were divided into four groups (n = 30): group I: silicone without pigment or opacifier, group II: ceramic powder pigment, group III: Barium sulfate (BaSO(4)) opacifier, and group IV: ceramic powder and BaSO(4) opacifier. Specimens of each group (n = 10) were disinfected with effervescent tablets, neutral soap, or 4% chlorhexidine gluconate. Disinfection was done three times a week during two months. Afterward, specimens were submitted to different periods of artificial aging. Color evaluation was initially done, after 60 days (disinfection period) and after 252, 504, and 1008 h of artificial aging with aid of a reflection spectrophotometer. Data were analyzed by three-way ANOVA and Tukey test (alpha = 0.05). The isolated factor disinfection did not statistically influence the values of color stability among groups. The association between pigment and BaSO(4) opacifier (GIV) was more stable in relationship to color change (Delta E). All values of Delta E obtained, independent of the disinfectant and the period of artificial aging, were considered acceptable in agreement with the norms presented in literature. (C) 2011 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.3625401]
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Neste estudo observamos a reação tecidual após implantação de próteses de silicone associadas à poliglactina 910. Telas de borracha de silicone com 1,5 x 1,5cm de diâmetro e 0,7mm de espessura, polifenestradas, foram implantadas no subcutâneo do dorso de ratos.Dois grupos foram observados, no primeiro apenas telas fenestradas eram implantadas, no segundo as fenestrações das telas eram preenchidas com fios de poliglactina 910. Os animais foram observados por 30, 60 e 90 dias quando eram sacrificados e as telas mais o tecido adjacente ressecados. Não se observou diferenças na quantidade de fibras colágenas entre os subgrupos de um mesmo grupo e ou quando comparados com os subgrupos do grupo em estudo. No grupo controle, onde se usou apenas as telas fenestradas de silicone houve uma diferença significante entre as fibras reticulares, em maior número nos grupos de 30 e 60 dias de observação, quando comparadas ao grupo de 90 dias. A poliglactina 910 associada ao silicone não alterou o número de fibras do tecido conjuntivo, contadas nas fenestrações das telas.
Análise histológica e morfométrica da área cruenta tratada com membrana de silicone: estudo em ratos
Resumo:
Background. Thin study evaluated the effects of a silicone membrane on the treatment of the raw flesh area in wounds.METHODS. The experimental study was carried out with 30 male Wistar rats divided into three groups: in the G(G) group, the raw area was treated with gauze, in the G(H) group with homograft, and in the G(S) group with a silicone membrane. Animals were sacrificed at fourteen days of postoperative. The studied attributes were body mass variation, histological study quantifed by morphometric analysis evaluating the number of neovessels, fibroblasts, collagen fibers, leucocytes, monocytes; and using a micrometric ruler measurement of the raw area thickness. Data were then submitted to statistical analysis.RESULTS. There was no significant difference between the animals' mass (p=0.0685). Predominance of neovessels (p<0.01), fibroblasts (p<0.001) and thickness of the raw flesh were observed in G(S) animals. There was predominance of leucocytes (p<0.021) and monocytes (p<0.0001) in G(H) animals. Also, no significant difference between the groups as for collagen fibers (p=0.0536) was observed.CONCLUSION. The silicone membrane promoted granulation tissue with a large number of neovessels, fibroblasts and greater thickness.
Resumo:
In this work it was investigated the effect of the exposure to different plasmas on the wettability of silicone samples. We have observed that oxygen. argon, and hydrogen glow discharges are quite effective in reducing the water contact angle of such polymer. However, indifferently to efficiency of the treatment, practically all the modified surfaces recovered great part of their original hydrophobicity. We have investigated this hydrophobic recovery using surface energy measurements and theoretical simulations based on the exponential decay of the population of polar groups on the surface. According to our results such recovery can be attributed to the decrease of polar species at the interface water-polymer surface.
Resumo:
The aim of the present study was to evaluate the effect of disinfection and accelerated ageing on the dimensional stability and detail reproduction of a facial silicone with different types of nanoparticle. A total of 60 specimens were fabricated with Silastic MDX 4-4210 silicone and they were divided into three groups: colourless and pigmented with nanoparticles (make-up powder and ceramic powder). Half of the specimens of each group were disinfected with Efferdent tablets and half with neutral soap for 60 days. Afterwards, all specimens were subjected to accelerated ageing. Both dimensional stability and detail reproduction tests were performed after specimen fabrication (initial period), after chemical disinfection, and after accelerated ageing periods (252, 504 and 1008 hours). The dimensional stability test was conducted using AutoCAD software, while detail reproduction was analysed using a stereoscope magnifying glass. Dimensional stability values were statistically evaluated by analysis of variance (ANOVA) followed by Tukey's test (p < 0.01). Detail reproduction results were compared using a score. Chemical disinfection and also accelerated ageing affected the dimensional stability of the facial silicone with statistically significant results. The silicone's detail reproduction was not affected by these two factors regardless of nanoparticle type, disinfection and accelerated ageing. © 2012 Informa UK, Ltd.
Resumo:
Several dermocosmetic bases even without active substances, can increase the cutaneous hydration, resulting in a beneficial effect to the skin. The evidence and interpretation of possible hydration effect of formulations in the skin can be carried through by means of histopathological and histomorphometrical evaluation, a time that allows the analysis of the epithelial tissue, of dermis and also of the cellular characteristics. The objective of this research was to evaluate the skin hydration after exposition to the aqueous and hydroalcoholic bases and silicone emulsion. Swines had areas submitted to treatments during 15 days with three different formulations (F1 - aqueous gel, F2 - hydroalcoholic gel and F3 - silicone emulsion). By means of histometric and histopathological techniques were gotten the thickness of the epidermis and stratum corneum. Comparison of means was done using ANOVA followed by the Tukey test. The F1 provoked significant increase in the thickness of the epidermis. The formulaton F2 provoked significant reduction in the thickness of the epidermis and stratum corneum. F3 not presented significant difference in this structures. According to the study, the type of base chosen intervenes with the skin hydration.