100 resultados para Transducers.
Resumo:
This work describes the use of a large-aperture PVDF receiver in the measurement of liquid density and composite material elastic constants. The density measurement of several liquids is obtained with accuracy of 0.2% using a conventional NDE emitter transducer and a 70-mm-diameter, 52-mu m P(VDF-TrFE) membrane with gold electrodes. The determination of the elastic constants is based on the phase velocity measurement. Diffraction can lead to errors around 1% in velocity measurement when using alternatively the conventional pair of ultrasonic transducers (1-MHz frequency and 19-mm-diameter) operating in through-transmission mode, separated by a distance of 100 mm. This effect is negligible when using a pair of 10-MHz, 19-mm-diameter transducers. Nevertheless, the dispersion at 10 MHz can result in errors of about 0.5%, when measuring the velocity in composite materials. The use of an 80-mm diameter, 52-mu m-thick PVDF membrane receiver practically eliminates the diffraction effects in phase velocity measurement. The elastic constants of a carbon fiber reinforced polymer were determined and compared with the values obtained by a tensile test. (C) 2009 Elsevier B. V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fast, selective, reproducible and reliable detections have been carried out by using enzymatic biosensors in several areas. The enzymatic biosensors based on the inhibition represent an important role in analytical chemistry. Enzymes like cholinesterases, peroxidases, tyrosinases, etc. have been immobilized on electrochemical and optical transducers and the enzymatic activity decreasing in the presence of the inhibitor is related with its concentrations. This article presents a review on the enzymes used on the construction of these sensors, emphasizing the respective applications.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The modified Cam - Clay model was used to model experimental results of a saturated residual sandy soil from Sao Carlos - SP. Triaxial compression tests were performed using Bishop - Wesley cell with internal transducers to measure axial and radial strains. It was observed that the model fairly fitted experimental results, specially the principal stress difference at critical state. In general it was observed a good qualitative agreement between experimental and predicted strain values, considering compression or expansion of the samples. However, in all the stress path used, but 100 degrees and 140 degrees, the model yielded strains larger than that measured in the tests.
Resumo:
The J(1)...J(3) is a recent optical method for linear readout of dynamic phase modulation index in homodyne interferometers. In this work, the J(1)... J(3) method is applied to measure voltage in an optical voltage sensor. Based on the classical J(1)...J(4) method, the J(1)... J(3) technique shows to be more stable to phase drift and simpler for implementation than the original one. The sensor dynamic range is enhanced. The agreement between theoretical and experimental results, based on 1/f noise, is demonstrated.
Resumo:
A measurement device has been developed to measure force and torque components acting on the impeller of a model pump-turbine, which uses crystal quartz load transducers installed on the rotating shaft. These kinds of load transducers allow greater stiffness than arrangements using strain gauges. Therefore, the dynamics behavior of the measurement device has to be taken into account. Some results of measurements are present in the whole operating range of model pump-turbine.
Resumo:
Temporal and spatial acoustic intensity (SATA) of therapeutic ultrasound (US) equipment should be monitored periodically. In order to evaluate the conditions of US equipment in use in the city of Piracicaba-Sao Paulo, Brazil, 31 machines - representing all Brazilian manufacturers - were analysed under continuous and pulsed conditions at a frequency of 1 MHz. Data about temporal and spatial acoustic intensity were collected and the use of equipment was surveyed. Intensities of 0.1, 0.2, 0.5, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0 Wcm -2, indicated on the equipment panel were analysed using a previously calibrated digital radiation pressure scale, model UPM-DT-1 (Ohmic Instruments Co). The acoustic intensity (I) results were expressed as superior and inferior quartile ranges for transducers with metal surfaces of 9 cm 2 and an effective radiation area (ERA) Of 4 cm 2. The results under continuous conditions were: I 0.1 = -20.0% and -96%. I 0.2 = -3.1% and -83.7%. I 0.5 = -35.0% and -86.5%. I 0.8 = -37.5% and -71.0%. I 2.5 = -49.0% and -69.5%. I 3.0 = -58.1% and -77.6%. For pulsed conditions, intensities were: I 0.1 = -40.0% and -86.2%. I 1.0 = -50.0% and -86.5%. I 1.5 = -62.5% and -82.5%. I 2.0 = -62.5% and -81.6%. I 2.5 = -64.7% and -88.8%. I 3.0 = -87.1% and -94.8%. In reply to the questionnaire drawn up to check the conditions of use of equipment, all users reported the use of hydrosoluble gel as a coupling medium and none had carried out previous calibrations. Most users used intensities in the range of 0.4. to 1.0 Wcm -2 and used machines for 300 to 400 minutes per week. The majority of machines had been bought during the previous seven years and weekly use ranged from less than 100 minutes to 700 minutes (11 hours 40 minutes). Findings confirm previous observations of discrepancy between the intensity indicated on the equipment panel and that emitted by the transducer and highlight the necessity for periodic evaluations of US equipment.
Resumo:
Atherosclerosis is a very common and important disease being the most important cause of mortality in Brazil. Indeed, in 1995, 23.3% of deaths, all ages, in our country, were the consequence of atherosclerosis. This percentage grows to 26.3% for S. Paulo and 32.7% for Rio Grande do Sul. Morphologically, there are 3 main types of lesions: fatty streaks, fibrous plaques, and complicated lesions. Fatty streaks are inocuous and occur early in life. In some persons, with age, they change into fibrous plaques that may lead to stenosis. They also may become complicated by erosion, calcification, hemorrhage and thrombosis. Atherosclerosis is initiated by endothelial functional alterations responsible for increase in permeability to macromolecules, adhesion, and migration of monocytes-macrophages and lymphocytes plus recruitment of platelets and smooth-muscle medial cells. Adhesion molecules, cytokines, growth factors, and free radicals are locally synthesized, favoring proliferation of extracellular matrix and progression of the lesion. Experimental, clinical, and epidemiological evidence point to the importance of lipids, mainly cholesterol-rich low-density lipoprotein (LDL), as one of the most important molecules involved in the genesis and progression of atherosclerosis. Patients with a genetic disorder of cholesterol metabolism (familial hyperlipidemia), caused by a decrease in the availability of receptors for LDL, develop severe atherosclerosis early in life. A series of other factors, such as age, diabetes melitus, diet, hypertension, lack of exercise, elevated hemocysteinemia, immunological disorders, and coagulation instability, are related to the progression of atherosclerosis. All of them are capable of altering the endothelium or increasing the offer of LDL. All the above-mentioned factors are systemic; but atherosclerosic lesions are focal, located at preferential sites such as the emergence of colaterals, bifurcations, and curvatures of arteries, all areas in which the laminar flow is disturbed. In these areas shear stress is diminished favoring the prolongation of permanence time of lipid particles, cells, cytokines, growth factors, etc., in the vicinity of the endothelium. Moreover, the endothelium has sensors that act as transducers of mechanical forces in biological responses. Experimental data demonstrate that the number and quality of adhesion molecules, cytokines, and growth factors synthetized, as well as the local production of radicals, and pro and anticoagulation factors may change with shear stress favoring or not the local establishment and progression of atherosclerotic lesions.
Resumo:
Measurements of ultrasonic attenuation and velocity in milk and low concentration water-in-oil (W/O) emulsion were conducted, using a measurement cell with a double-element transducer that eliminates diffraction losses. The milk is characterized by the attenuation coefficient, while in the case of water-in-oil emulsions, the characterization is best represented by the propagation velocity.
Resumo:
This study aimed to relate embryonic/fetal vesicle diameter (EVD) and crown-rump length (CRL) to gestational age in ewes from the 15 th to the 45 th day of pregnancy. Nineteen adult Bergamácia ewes with synchronized estrus were mated by the same male. Ultrasonographic evaluations were performed every 24 hours from the 15 th to the 30 th day after mating and every five days from the 30 th to the 45 th day using 5.0 and 7.5MHZ linear transducers. Average daily growth of EVD and CRL were 1.40mm and 1.33mm, respectively. The inverse calibration obtained for EVD was: Days = -11 + 50(0.1 + 0.04log EVD) 1/2 with R 2 = 0.85, and for CRL was: Days = 13.63 + 12.5(- 0.71 + 0.16CRL) 1/2 with R 2 = 0.93. Both EVD and CRL obtained by ultrasonography are useful measurements that allow the prediction of gestational age in Bergamácia ewes.
Resumo:
The instrumentation applied to the Charpy test machine allows the accompaniment of the specimen answer front the impact load, in form of a sign characteristically dynamic representative of the deformation process and it fractures of material tested. The main advantages of the rehearsal conventional Charpy: low cost, manufacturing sample facilities and simple handle the machine. With the instrumentation, the number of information regarding the process of fracture of the specimen increases. In this work discusses the influence of the hammer geometry in determination of the force during the process of specimen fracture submitted to the instrumented impact test Charpy-V. The purpose is obtaining a hammer, in conformity with Norma ISO 14.556, with great sensibility to register the force during the impact. Two geometries different from hammers were instrumented and rehearsed with material of low tenacity, in this case the steel ABNT 4140 in the condition of having normalized. It could be proven as larger the sensibility of the hammer, adult will be the effects of the shock waves in the strain gages of the transducer.
Resumo:
A 1000-kgf resistive strain-gauge load cell has been developed for quality testing of rocket propellant grain. A 7075-T6 aluminum alloy has been used for the elastic column, in which 8 uniaxial, 120-Ω strain gauges have been bonded and connected to form a full Wheatstone bridge to detect the strain. The chosen geometry makes the transducer insensitive to moments and, also, to the temperature. Experimental tests using a universal testing machine to imposed compression force to the load cell have demonstrated that its behavior is linear, with sensitivity of 2.90 μV/kgf ± 0.34%, and negligible hysteresis. The designed force transducer response to a dynamic test has been comparable to that of a commercial load cell. © 2005 IEEE.