21 resultados para Total atomic charges
Resumo:
The secondary electron emission of dielectrics usually is measured by the pulse method, in which the dielectric is irradiated with short pulses of electrons. Attempts to use a dynamic method, in which the dielectric is irradiated continuously, have failed because the dielectric becomes charged and this charge interferes with the emission process. The dynamic method can, however, be applied to metals where volume charges are prevented. This article reports dynamic measurements of the total secondary emission yield from stainless steel, platinum, and aluminum and compares them with results from the current pulse method. In order to apply the dynamic method to metals a simple but important change in the setup was introduced: a dielectric slab was placed between the electrode and the metallic sample, which permitted the sample surface potential and therefore the energy of the incident electrons to change continuously. Unlike for dielectrics, the emission curves for metals are identical when obtained by the two methods. However, for a sample with deliberately oxidized surfaces the total secondary emission yield is smaller when measured with the dynamic method as compared with the pulse method, just as happens for dielectrics. (C) 2000 American Institute of Physics. [S0021-8979(00)03413-7].
Resumo:
In this work, a preconcentration and separation system based on continuous flow hydride generation is proposed to improve the determination of As and Se by total reflection X-ray fluorescence spectrometry. The generated hydrides are continuously separated from the liquid phase and collected in a chamber containing 250 mul of HCI/HNO3 1:1 (v/v) solution. Hydride generation conditions and collection of the hydrides were evaluated. Under optimised conditions, enrichment factors of 55 for As and 82 for Se were attained. Detection limits of 0.3 mug l(-1) for As and Se were obtained when 20 ml of sample was used. Analysis of a natural water standard reference material from National Institute of Standard and Technology (SRM-1640) was in agreement with the certified values at the 95% confidence level. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
We use relativistic mean field theory, which includes scalar and vector mesons, to calculate the binding energy and charge radii in 125Cs - 139Cs. We then evaluate the nuclear structure corrections to the weak charges for a series of cesium isotopes using different parameters and estimate their uncertainty in the framework of this model.
Resumo:
A técnica radioterápica Total Skin Irradiation (TSI), utilizada para tratamento de Micose Fungóide e doenças similares, apresenta grande complexidade na sua dosimetria e implementação nos Serviços de Radioterapia. No SUS – Sistema Único de Saúde - do Brasil, só há esse tratamento no Serviço de Radioterapia do Hospital das Clínicas da UNICAMP (Campinas) e no Instituto Nacional do Câncer (INCA) (Rio de Janeiro). O objetivo deste trabalho é o estudo e o desenvolvimento de um protocolo de controle de qualidade e dosimetria a ser implementado na técnica utilizada no Serviço de Radioterapia do Hospital de Clínicas da Universidade Estadual de Campinas (HC - UNICAMP). Todos os estudos e análises para a elaboração do protocolo foram baseados no Report 23[1] da AAPM – American Association of Physicists in Medicine - e no TRS-398[3] da IAEA – International Atomic Energy Agency. A metodologia e os resultados obtidos apresentam-se descritos neste relatório
Resumo:
To determinate the multielemental concentrations in biological samples using the technique of total reflection X-ray fluorescence (TRFX) is essential the use of standard samples. The aim of this study is the determination of the sensitivities of the relevant elements in standard samples (Multi Element atomic spectroscopy standard solution in HNO3 I) prepared in three solutions with different and known concentrations. Based on the sensitivities of the elements contained in the multilelementar standard sample, it can estimate the sensitivity for an element found in the biological sample and consequently it is possible to determinate the concentration, even though the standard does not contain this element. The measurement of fluorescence was performed at the Brazilian Synchrotron Light Laboratory (LNLS) in Campinas