21 resultados para Taxa de câmbio real


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Zootecnia - FCAV

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper consists in the evaluation of the exposure rate to ionizing radiation to which professionals working in surgical procedures which require radiological examinations are subjected. Were initially performed real-time readings of exposure rate within four distinct operating rooms during the execution of four surgical procedures that made use of fluoroscopy equipment (including three orthopedic surgeries, one in the shoulder, one in the arm, another for deployment of metal pin in the leg region, and a fourth for vascular procedure); in these surgeries were used ionization chamber detector and an electrometer. In order to check the values achieved, was made a re-evaluation of the distribution of the rate of exposure to radiation, from the surgical procedures, now with thermoluminescent dosimeters (TLDs). For this, thirty TLDs were distributed in the operating rooms, arranged in points of interest as occupation by professionals. The TLDs were prepared for thirty consecutive days, after which they were removed and replaced with new dosimeters not exposed yet. The dosimeters were subjected to reading of the rate of exposure; this procedure was repeated for four months without interruption. The quantification of the results sought primarily to convert the rate of exposure for equivalent dose rate, both in measurements with ionization chamber as in measurements with TLDs, in order to highlight the presence of the biological effect of ionizing radiation for comparisons within scientific context. Then, the results were plotted to establish the relationship between the values of equivalent dose and the distance to the central axis of the x -ray source, confirming the inverse square law for distance. Finally, the values were associated with the maximum limit recommended by the legislation for occupationally exposed individuals. The methodology for the analysis and quantification of the data in this work aims at implementing a work plan that meets ...

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to investigate the performance of an experimental rainwater treatment system for non-potable uses. Without the first-flush discharge it was expected to control the quality of captured rainwater and to minimize the rainwater by-pass caused by the first-flush strategy. A full-scale direct filtration unit was operated and a solution of natural corn starch was used as the primary coagulant. The color, turbidity e coliform efficiencies of the unit was analyzed based on filtration loads and the net water production was estimated. The results pointed out turbidity removal up to 70.8% and color removal up to 61.0%. The backwash of the filtering system was completed in 3 minutes at the rate of 1,440 m3/m2day with consumption of treated water from 0.5% to 2.2%, based on the potentially harvesting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The real role of renal transplantation in hepatic fi brosis progression caused by hepatitis C virus is still unpredictable. Histological evaluation of the liver is the best form to estimate fi brosis evolution, although semiquantitative analysis carries important limitations. Objective: To apply a morphometric quantitative assay on hepatic fi brosis progression in renal recipients with hepatits C. Methods: Thirty patients were initially evaluated, but only seven were included. They underwent the fi rst biopsy near the transplantation date and the second biopsy at least 4 years later. The immunosuppressant therapy adopted in all cases was azatioprine and micofenolate. Fibrosis progression rate (FPR) was calculated before and after the surgery date in each patient according to Metavir score and morphometric analysis. Results: The FPR calculated by Metavir score showed no statistical difference between pre- and post-transplantation (p=0.9). The FPR calculated by the morphometric analysis was 0.58 ± 0.78 before transplantation and 3.0 ± 3.3 after the surgery, with statistical signi- fi cance between these values (p=0.0026). Conclusion: In the sample assessed, the progression of hepatic fi brosis was documented and quantifi ed only by the morphometric analysis, which is as a promising approach to histological evaluation of these patients.