36 resultados para System Effectiveness


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The aim of the present study was to evaluate the prevention and self-inspection behavior of diabetic subjects with foot at ulcer risk, no previous episode, who participated in the routine visits and standardized education provided by the service and who received prescribed footwear. This evaluation was carried out using a questionnaire scoring from 0-10 (high scores reflect worse practice compliance).Results: 60 patients were studied (30 of each sex); mean age was 62 years, mean duration of the disease was 17 years. As for compliance, 90% showed a total score <= 5, only 8.7% regularly wore the footwear supplied; self foot inspection 65%, 28,3% with additional familiar inspection; creaming 77%; proper washing and drying 88%; proper cutting of toe nails 83%; no cuticle cutting 83%; routine shoe inspection 77%; no use of pumice stones or similar abrasive 70%; no barefoot walking 95%.Conclusion: the planned and multidisciplinary educational approach enabled high compliance of the ulcer prevention care needed in diabetic patients at risk for complications. In contrast, compliance observed for the use of footwear provided was extremely low, demonstrating that the issue of its acceptability should be further and carefully addressed. In countries of such vast dimensions as Brazil multidisciplinary educational approaches can and should be performed by the services providing care for patients with foot at risk for complications according to the reality of local scenarios. Furthermore, every educational program should assess the learning, results obtained and efficacy in the target population by use of an adequate evaluation system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main objective of this article is to analyze the policy implanted in the schools in the State of São Paulo, Brazil, with a view to the prevention and intervention in the violence that occurs in the schools. The importance of such discussion is related to the analysis of the principles that are present and of the possible effectiveness of such a program in the school violence. This research is qualitative and the research methodology used was documentary analysis. The documents analyzed were those related to the policy of preventing violence in schools in the state of São Paulo/Brazil, called Protection System School. (C) 2012 Published by Elsevier Ltd. Selection and/or peer-review under responsibility of The Association of Science, Education and Technology

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents two discrete sliding mode control (SMC) design. The first one is a discrete-time SMC design that doesn't take into account the time-delay. The second one is a discrete-time SMC design, which takes in consideration the time-delay. The proposed techniques aim at the accomplishment simplicity and robustness for an uncertainty class. Simulations results are shown and the effectiveness of the used techniques is analyzed. © 2006 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: The purpose of this study was to compare the effectiveness of a high-volume evacuation and a conventional intraoral suction system and aspirating tips for capturing aluminum oxide particles during use of an air-abrasion device. Methods: A phantom head was fixed at the dental chair head with secured a metallic device with 5 horizontal shafts, corresponding to operator's clockrelated working positions, and one vertical shaft to simulate the operator's nasal cavity. Petri plates were fixed to the shafts at distances of 20, 40 and 60 cm from the center of the oral cavity of the phantom head to collect the aluminum oxide particles spread over during air abrasion. The dust was aspirated with two types of suction tips used with both suction systems: a conventional saliva ejector and a saliva ejector customized by the adaptation of a 55-mm-diameter funnel. Results: The amount of particles showed that the greatest abrasive particle deposition occurred at a distance of 20 cm from the center of the oral cavity of the phantom head at 9 o'clock operatory position with the conventional saliva ejector attached to high-volume evacuation system. Conclusions: The greatest deposition of aluminum oxide particles occurred at the shortest distance between the operator and the center of the oral cavity, while using the high-volume evacuation system associated to the conventional suction tip.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effectiveness of manual and rotary instrumentation techniques for removing root fillings after different storage times. Twenty-four canals from palatal roots of human maxillary molars were instrumented and filled with gutta-percha and zinc-oxide eugenol-based sealer (Endofill), and were stored in saline for 6 years. Non-aged control specimens were treated in the same manner and stored for 1 week. All canals were retreated using hand files or ProTaper Universal NiTi rotary system. Radiographs were taken to determine the amount of remaining material in the canals. The roots were vertically split, the halves were examined with a clinical microscope and the obtained images were digitized. The images were evaluated with AutoCAD software and the percentage of residual material was calculated. Data were analyzed with two-way ANOVA and Tukey's test at 5% significance level. There was no statistically significant differences (p>0.05) between the manual and rotary techniques for filling material removal regardless the ageing effect on endodontic sealers. When only the age of the filling material was analyzed microscopically, non-aged fillings that remained on the middle third of the canals presented a higher percentage of material remaining (p<0.05) compared to the aged sealers and to the other thirds of the roots. The apical third showed a higher percentage of residual filling material in both radiographic and microscopic analysis when compared to the other root thirds. In conclusion, all canals presented residual filling material after endodontic retreatment procedures. Microscopic analysis was more effective than radiographs for detection of residual filling material.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper adjusts decentralized OPF optimization to the AC power flow problem in power systems with interconnected areas operated by diferent transmission system operators (TSO). The proposed methodology allows finding the operation point of a particular area without explicit knowledge of network data of the other interconnected areas, being only necessary to exchange border information related to the tie-lines between areas. The methodology is based on the decomposition of the first-order optimality conditions of the AC power flow, which is formulated as a nonlinear programming problem. To allow better visualization of the concept of independent operation of each TSO, an artificial neural network have been used for computing border information of the interconnected TSOs. A multi-area Power Flow tool can be seen as a basic building block able to address a large number of problems under a multi-TSO competitive market philosophy. The IEEE RTS-96 power system is used in order to show the operation and effectiveness of the decentralized AC Power Flow. ©2010 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intrusion detection systems that make use of artificial intelligence techniques in order to improve effectiveness have been actively pursued in the last decade. Neural networks and Support Vector Machines have been also extensively applied to this task. However, their complexity to learn new attacks has become very expensive, making them inviable for a real time retraining. In this research, we introduce a new pattern classifier named Optimum-Path Forest (OPF) to this task, which has demonstrated to be similar to the state-of-the-art pattern recognition techniques, but extremely more efficient for training patterns. Experiments on public datasets showed that OPF classifier may be a suitable tool to detect intrusions on computer networks, as well as allow the algorithm to learn new attacks faster than the other techniques. © 2011 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper investigates the most desirable configuration of a two-stage nonlinear vibration isolation system, in which the isolators contain hardening geometric stiffness nonlinearity and linear viscous damping. The force transmissibility of the system is used as the measure of the effectiveness of the isolation system. The hardening nonlinearity is achieved by placing horizontal springs onto the suspended and intermediate masses, which are supported by vertical springs. It is found that nonlinearity in the upper stage has very little effect and thus serves little purpose. The nonlinearity in the lower stage, however, has a profound effect, and can significantly improve the effectiveness of the isolation system. Further, it is found that it is desirable to have high damping in the upper stage and very low damping in the lower stage. © 2012 Elsevier Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study evaluated the effectiveness and the sensitivity of in-office tooth bleaching with the use of a hybrid photo-activation system composed by LEDs and lasers. 40 patients, both genders, aged 18 through 25 years, were randomly distributed into two treatment groups: group I, 35% hydrogen peroxide, with a total bleaching time of 135 min divided into three sessions, and group II, 35% hydrogen peroxide and photo-thermal catalysis by an LED-laser system (300 mW cm-2), for a total bleaching time of 72 min divided into three sessions. The treatment efficiency was measured by reflectance spectroscopy and sensitivity by a visual analog scale (VAS). The final luminosity value (ΔL), color variation (ΔE) and sensitivity (S) resulting from the treatments were analyzed by the generalized estimating equations method (GEEs), and Bonferroni post hoc multiple comparisons at 5% significance. The two groups presented similar colors (ΔE) and luminosities (ΔL) after treatment. Group I presented a greater sensitivity index (37.6 ± 5.9%) compared to group II (11.1 ± 3.3%), statistically significant at p < 0.05. The use of LED-laser hybrid light, as a catalyst of the bleaching agents, showed a significant decrease of provoked tooth sensitivity and a treatment time reduced by 53%, with the same aesthetic results as without a light source. © 2013 Astro Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Besides possessing good mechanical properties, dental materials should present a good biological behavior and should not injure the involved tissues. Bond strength and biocompatibility are both highly significant properties of dentin adhesives. For that matter, these properties of four generations of adhesive systems (Multi-Purpose/Single Bond/SE Plus/Easy Bond) were evaluated.Eighty bovine teeth had their dentin exposed (500- and 200-mu m thickness). Adhesive was applied on the dentin layer of each specimen. Following that, the microshearing test was performed for all samples. A dentin barrier test was used for the cytotoxicity evaluation. Cell cultures (SV3NeoB) were collected from testing materials by means of 200- or 500-mu m-thick dentin slices and placed in a cell culture perfusion chamber. Cell viability was measured 24 h post-exposition by means of a photometrical test (MTT test).The best bonding performance was shown by the single-step adhesive Easy Bond (21 MPa, 200 mu m; 27 MPa, 500 mu m) followed by Single Bond (15.6 MPa, 200 mu m; 23.4 MPa, 500 mu m), SE Plus (18.2 MPa, 200 mu m; 20 MPa, 500 mu m), and Multi-Purpose (15.2 MPa, 200 mu m; 17.9 MPa, 500 mu m). Regarding the cytotoxicity, Multi-Purpose slightly reduced the cell viability to 92 % (200 mu m)/93 % (500 mu m). Single Bond was reasonably cytotoxic, reducing cell viability to 71 % (200 mu m)/64 % (500 mu m). The self-etching adhesive Scotchbond SE decreased cell viability to 85 % (200 mu m)/71 % (500 mu m). Conversely, Easy Bond did not reduce cell viability in this test, regardless of the dentin thickness.Results showed that the one-step system had the best bond strength performance and was the least toxic to pulp cells. In multiple-step systems, a correct bonding technique must be done, and a pulp capping strategy is necessary for achieving good performance in both properties.The study showed a promising system (one-step self-etching), referring to it as a good alternative for specific cases, mainly due to its technical simplicity and good biological responses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A large proportion of fresh water is greatly impaired due to increasing pollution; this could be minimized through the expansion of investment in sanitation programs. But the major problem faced by third world countries and developing ones in this respect, is the high cost of projects and their implementation. In an attempt to find a simple technology, efficient and inexpensive, this study aimed to verify the effectiveness of using constructed wetland systems (CWS) for removal of bacteria and nutrients from sanitary sewer effluent from the STS Piracicamirim - Piracicaba - SP. The installation of prototypes was followed, and testing prior to regularize the flow held, but due to malfunction of these and outages of the STS activity can not evaluate the effectiveness of both as to the parameters proposed: temperature, pH, dissolved oxygen, conductivity, total dissolved solids (TDS), nitrite, nitrate, ammonia, total nitrogen, total phosphorus, chemical oxygen demand (COD), sulfide, sulfate, biochemical oxygen demand (BOD), total coliform and Escherichia coli. To establish results about the effectiveness of these types if the system were conducted literature reviews of papers published with the same theme. Analysis of these results showed fairly good efficiencies in wastewater treatment, especially for nutrients and coliforms

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Lateral condensation effectiveness may be influenced by the gutta-percha and finger spreader taper used during root canal obturation. Objective: To evaluate the penetration ability of finger spreader into simulated root canals prepared using MTwo rotary system and filled with different gutta-percha and finger spreader tapers. Material and methods: Resin blocks with curved root canals had the apical diameter enlarged up to #25.06 and distributed into groups (n = 6) according to the gutta-percha taper (#25.02, #25.04, and #25.06) and the finger spreader (#30 and #35 NiTi, and stainless steel B) used to perform cold lateral condensation. After applying a load of 1.5 Kg over the finger spreaders’ head, the distance between the finger spread tip and the apical limit of the root canal preparation were obtained. The data were submitted to Anova and Tukey-Krammer’s test, with 5% of significance. Results: The gutta-percha cones with 0.02 taper enabled higher finger spreader penetration when compared to 0.04 and 0.06 tapers (p < 0.05), which were similar between each other (p > 0.05), regardless of the type and diameter of the finger spreader used. When different finger spreaders were compared among themselves, stainless steel B showed higher penetration ability (p < 0.05). Conclusion: It was concluded that the stainless-steel finger spreaders showed superior penetration ability and gutta-percha with lower tapers enabled a more effective lateral condensation at the apical third.