117 resultados para Synthetic diamond
Resumo:
The etiology of hormone-induced cancers has been considered to be a combination of genotoxic and epigenetic events. Currently, the Comet assay is widely used for detecting genotoxicity because it is relatively simple, sensitive, and capable of detecting various kinds of DNA damage. The present study evaluates the genotoxic potential of endogenous and synthetic sex hormones, as detected by the Comet assay. Blood cells were obtained from 12 nonsmoking and 12 smoking women with regular menstrual cycles and from 12 nonsmoking women taking low-dose oral contraceptives (OC). Peripheral blood samples were collected at three phases of the menstrual cycle (early follicular, mean follicular, and luteal phases), or at three different moments of oral contraceptive intake. Three blood samples were also collected from 12 healthy nonsmoking men, at the same time as oral contraceptive users. Results showed no significant difference in the level of DNA damage among the three moments of the menstrual cycle either in nonsmoking and smoking women, or between them. No significant difference in DNA damage was also observed among oral contraceptive users, nonusers, and men. Together, these data indicate lack of genotoxicity induced by the physiological level of the female sex hormones and OC as assessed by the alkaline Comet assay. In conclusion, normal fluctuation in endogenous sex hormones and use of low-doses of oral contraceptive should not interfere with Comet assay data when this technique is used for human biomonitoring.
Resumo:
The aim of this study was to compare the micromorphology of CVD diamond tips coupled to ultrasound with conventional high speed diamond tips after cavity preparations, and to measure the width and depth of the cavities obtained. Two hundred bovine teeth were divided into 20 subgroups. Each of the diamond tips (10 CVD and 10 conventional) were used to prepare 10 standardized cavities, using an apparatus that controlled the time (t: 27 s), speed (5.3 mm/s) and load (0.012 KGF) of the tip against the teeth during preparation. The unused and the used (after one, five and 10 preparations) tips were analyzed by scanning electronic microscopy. The images were randomly assessed by 3 examiners with regard to the presence or absence of micromorphologic alterations. Cavity measurements were made after visualization under a stereoscopic microscope. Cavity widths and depths were analyzed by the ANOVA Factorial test (p < 0.05). The CVD diamond tips presented less wear than the conventional tips after all the cavity preparations performed, but produced shallower cavities that were equivalent in width to those made by conventional tips after the fifth preparation. CVD diamond tips may be suggested as an alternative to conventional diamond tips due to their conservative preparation and greater longevity.
Resumo:
Purpose: To analyze the smear layer and the hybrid layer in noncarious and carious dentin prepared by different cutting instruments and restored with composite resin. Study design: Cavities were randomly prepared in 160 specimens (noncarious and artificial carious dentin) by high-speed diamond tips (KG Sorensen 1013), air abrasion system (Prepstart, Danville Engineering), ultrasonic tip (CVDentus 8.3231-1), and ultrasonic tip associated with ultrasonic cavitation by water for 10 s. Half of the cavities in each group were conditioned with 37% phosphoric acid for 15 s. The amount of smear layer and dentinal tubules present were analyzed using scanning electron microscopy and graded from 0 to 3. Cavities were prepared in another 20 noncarious specimens and 20 carious specimens and restored with adhesive composite resin system. The restorations were hemisected longitudinally and analyzed using scanning electron microscopy to evaluate the hybrid layer and resinous prolongation characteristics, using scores ranging from 1 to 6. Results: The data were statistically analyzed using Kruskal-Wallis and Dunn tests at 5% of significance level. There was evidence that the most efficient smear layer removal was the acid etching in the noncarious dentin and the water ultrasonic cavitation in the carious dentin. The hybrid layer formed on the noncarious and carious dentin prepared by the ultrasonic tip was more regular than in the specimens prepared by high-speed diamond tip, with many resinous prolongations. Conclusion: The ultrasonic tip seems to be a promising tool for carious dentin cavity preparation. Microsc. Res. Tech. 73:597-605, 2010. (C) 2009 Wiley-Liss, Inc.
Resumo:
Trans-dehydrocrotonin, the major diterpene isolated from the bark of Croton cajucara, has good antiulcerogenic activity which, however, is accompanied by toxic effects. on the basis of these results, a semi-synthetic crotonin, named 4SRC, was prepared to determine whether this substance has similar antiulcerogenic activity with lower or no toxicity. The natural crotonin was also isolated from the bark of C. cajucara but was not used due to the small amount obtained. The cytotoxic effect of semi-synthetic crotonin, expressed as cell viability, was assessed in (a) lung fibroblast cell line (V79) derived from Chinese hamsters, a system commonly used for cytotoxicity studies, and (b) rat hepatocytes isolated from male Wistar rats. After treatment, cell viability was determined by 3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2H-tetrazolium bromide reduction (MTT reduction), total acid content and neutral red uptake assays. To evaluate V79 cell viability, different concentrations of semi-synthetic crotonin were incubated with the cells. To evaluate the antiulcerogenic effects of semi-synthetic crotonin (50, 100 and 200 mg/kg), we used the models of gastric ulcer induced by ethanol/HCl, stress, indomethacin/bethanechol, and ethanol in male Swiss mice and male Wistar rats. The substance had an IC50 = 500 muM in the neutral red uptake and MTT reduction tests and an IC50 = 200 muM in the nucleic acid content test. With regard to hepatocyte viability after treatment with semi-synthetic crotonin at different concentrations, semi-synthetic crotonin had an IC50 = 10-500 muM in the nucleic acid content and MTT reduction tests and an IC50 = 120 muM in the neutral red uptake test. In another experiment, V79 cells were incubated with the metabolites produced by hepatocytes treated with different concentrations of semi-synthetic crotonin. After a 4-h incubation, semi-synthetic crotonin had an IC50 = 500 muM in the MTT reduction and neutral red uptake tests and an IC50 = 370 muM in nucleic acid content test. The substance had significant antiulcerogenic activity in all models studied, suggesting the presence of a possible antisecretory effect combined with a cytoprotective effect. For this reason, the effect of semi-synthetic crotonin was also evaluated on biochemical parameters of gastric juice and gastric wall mucus, both obtained from pylorus-ligated mice. No significant differences were observed in these parameters between semi-synthetic crotonin-treated and control animals. The results obtained with semi-synthetic crotonin are promising, with a significant preventive effect against gastric ulcer induced by different agents. Our data also show that semi-synthetic crotonin was less toxic than dehydrocrotonin and that the cytotoxic effects decreases with the time that isolated hepatocytes were in culture. (C) 2003 Elsevier B.V. B.V. All rights reserved.
Resumo:
The effect of three new derivatives from dehydrocrotonin (DHC-compound I) on gastric damage indifferent animal models including gastric ulceration induced by a necrotic agent and hypothermic restrained-stress was studied: compound 11 (produced by reducing the cyclohexenone moiety of DHC with NaBH4): compound III (produced by reducing the carbonyls with LiAlH4); and compound IV (produced by transforming the lactone moiety into an amide). Their structures were confirmed on the basis of chemical and physicochemical evidence. When previously administered (p.o.) at a dose of 100 mg/kg, compound II significantly (P < 0.01) reduced gastric injury induced by HCl/ethanol (78%) and indomethacin (88%) better than did reference compound 1 (48 and 43%, respectively). But the anti-ulcerogenic activity of compound II was completely abolished by the stress-induced ulcer. Reduction of carbonyls with LiAlH4 (compound 111) caused decreased activity, markedly when no protective effect in any of the models was applied (P > 0.05). However, compound IV, in which the lactone moiety was changed into an amide. when administered at the same dose (100 mg/kg, p.o.), was more effective. The presence of a lactone moiety or Michael acceptor is probably essential for the anti-ulcerogenic effect of these compounds. (C) 2003 Elsevier B.V. Ireland Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this study, we evaluated the involvement of rat ventral prostate smooth muscle cells (SMC) in secretory activity and whether this function is modulated after castration. Cell morphology was examined at both light and electron microscopy levels and the organelles involved in secretory function were labeled by the zinc-iodide-osmium (ZIO) method at the ultrastructural level and their volume density was determined by stereology. Castration resulted in marked changes of the SMC, which adopted a spinous aspect and abandoned the layered arrangement observed in the prostates of non-castrated rats. The volume density of ZIO reactive organelles increased progressively after castration, reaching significantly higher levels 21 days after castration, Since previous studies have demonstrated that SMC express SMC markers (even 21 days after castration) and are able to respond to adrenergic stimulation, we concluded that differentiated SMC are able to shift from a predominantly contractile to a more synthetic phenotype without changing their differentiation status. (c) 2005 International Federation for Cell Biology. Published by Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: The aim of this study was to evaluate the influence of dentin abrasion on the microshear bond strength of two self-etching adhesive systems, using either an ultrasound diamond bur or a high-speed diamond bur.Materials and Methods: Twenty noncarious human third molars were sectioned mesiodistally into halves. The enamel was ground to expose a flat dentin surface on both sections. The dentinal surfaces were randomly assigned to two groups, depending on the method of smear layer preparation: ultrasound diamond bur (UB) or conventional diamond bur (CB). The prepared dentin surfaces received one of two self-etching systems: Clearfil SE Bond (CF) and One-Up Bond F (OB). A composite cylinder with a 0.95-mm diameter was bonded to each specimen and the microshear bond test was performed. The results were expressed in MPa and were subjected to two-way analysis of variance (ANOVA) and Tukey's test (alpha = 0.05).Results: There was no significant difference in dentin bond strength when comparing the conventional and ultrasonic abrasion methods. When the adhesive systems were compared, Clearfil SE Bond achieved higher bond strength means than did One-Up Bond F.Conclusion: The dentin surface preparation method did not influence the microshear bond strength and the Clearfil SE Bond adhesive system, independent of bur type used, Clearfil SE Bond showed higher bond strengths than did the One-Up Bond F adhesive system.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)