106 resultados para Synthetic clay


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The organo-clay used in this work was prepared from a Na-montmorillonite (Wyoming-USA deposit) by treatment with water solution of hexadecyltrimethylammonium cations. As organo-clays exhibit strong sorptive capabilities for organic molecules, 2-mercapto-5-amino-1,3,4-thiadiazole organofunctional groups, with potential usefulness in chemical analysis, were incorporated on its solid surface. The physically adsorbed reagent did not present any restrictions in coordinating with several metal ions on the surface. The resultant organo-clay complex exhibited strong sorptive capability for removing mercury ions from water in which other metals and ions were also present. The purpose of this work is to study the selective separation of mercury(II) from aqueous solution using the organo-clay complex, measured by batch and chromatographic column techniques, and its application as preconcentration agent in a chemically modified carbon paste electrode for determination of mercury(II) in aqueous solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the acquisition of suture skills by training on ethylene-vinyl acetate bench model in novice medical students.METHODS: Sixteen medical students without previous surgery experience (novices) were randomly divided into two groups. During one hour group A trained sutures on ethylene-vinyl acetate (EVA) bench model with feedback of instructors, while group B (control) received a faculty-directed training based on books and instructional videos. All students underwent a both pre-and post-tests to perform two-and three-dimensional sutures on ox tongue. All recorded performances were evaluated by two blinded evaluators, using the Global Rating Scale.RESULTS: Although both groups have had a better performance (p<0.05) in the post-test when compared with the pre-test, the analysis of post-test showed that group A (EVA) had a better performance (p<0.05) when compared with group B (control).CONCLUSION: The ethylene vinyl acetate bench model allowed the novice students to acquire suture skills faster when compared to the traditional model of teaching.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We placed spheres of synthetic hydroxyapatite (calcium chloride combined with sodium phosphate) in the eviscerated or enucleated orbital cavity of rats in order to evaluate the biocompatibility of this material with the orbital cavity. The study was conducted on 50 albino rats, 25 of which were submitted to enucleation and 25 to evisceration of one eye. The animals were sacrificed 7, 15, 21, 30 and 60 days after surgery and the orbital content was submitted to histopathological examination. A reaction of the young granulation tissue type was observed first. The hydroxyapatite was gradually surrounded by a granulomatous macrophage inflammatory response and covered with dense connective tissue that formed a sort of mesh septating and supporting progressively smaller blocks of the substance. The same type of reaction was observed in the enucleated and eviscerated cavities. We conclude that synthetic hydroxyapatite is an inert nonallergenic material which is appropriate for volume replacement in the anophthalmic cavity

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Synthetic hydroxyapatite and porous polyethylene (Polipore) spheres were placed in rabbits' eviscerated cavities to evaluate tissue reaction and volume maintenance.Methods. Fifty-six Norfolk albino rabbits underwent unilateral evisceration and implantation of synthetic hydroxyapatite (H group, 28 animals) or porous polyethylene spheres (P group, 28 animals). Postoperative reactions, animal behavior, and socket conditions were monitored. Light microscopy and morphometric evaluation with statistical analysis of the exenterated orbits were performed at 7, 15, 30, 60, 90, 120, and 180 days. Scanning electron microscopy was appraised 7, 60, and 180 days after surgery.Results: Two animals from the H group and 1 from the P group had extrusion 7 days after surgery. Throughout the experimental period, the synthetic hydroxyapatite caused more inflammation than the porous polyethylene material. Ingrowth in the sphere occurred 7 to 15 days after the surgery in both groups, and the tissue reaction became denser at approximate to60 to 90 days, when bony metaplasia began in the H group. Volume maintenance was better in the P group and with a smaller pseudocapsule surrounding the implanted sphere than in the H group.Conclusions: Clinical findings demonstrated mild inflammation inside the sphere and in the pseudocapsule surrounding it and better cavity volume maintenance in the P group animals. The authors consider porous polyethylene a more suitable material than synthetic hydroxyapatite for use in anophthalmic cavity reconstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The etiology of hormone-induced cancers has been considered to be a combination of genotoxic and epigenetic events. Currently, the Comet assay is widely used for detecting genotoxicity because it is relatively simple, sensitive, and capable of detecting various kinds of DNA damage. The present study evaluates the genotoxic potential of endogenous and synthetic sex hormones, as detected by the Comet assay. Blood cells were obtained from 12 nonsmoking and 12 smoking women with regular menstrual cycles and from 12 nonsmoking women taking low-dose oral contraceptives (OC). Peripheral blood samples were collected at three phases of the menstrual cycle (early follicular, mean follicular, and luteal phases), or at three different moments of oral contraceptive intake. Three blood samples were also collected from 12 healthy nonsmoking men, at the same time as oral contraceptive users. Results showed no significant difference in the level of DNA damage among the three moments of the menstrual cycle either in nonsmoking and smoking women, or between them. No significant difference in DNA damage was also observed among oral contraceptive users, nonusers, and men. Together, these data indicate lack of genotoxicity induced by the physiological level of the female sex hormones and OC as assessed by the alkaline Comet assay. In conclusion, normal fluctuation in endogenous sex hormones and use of low-doses of oral contraceptive should not interfere with Comet assay data when this technique is used for human biomonitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trans-dehydrocrotonin, the major diterpene isolated from the bark of Croton cajucara, has good antiulcerogenic activity which, however, is accompanied by toxic effects. on the basis of these results, a semi-synthetic crotonin, named 4SRC, was prepared to determine whether this substance has similar antiulcerogenic activity with lower or no toxicity. The natural crotonin was also isolated from the bark of C. cajucara but was not used due to the small amount obtained. The cytotoxic effect of semi-synthetic crotonin, expressed as cell viability, was assessed in (a) lung fibroblast cell line (V79) derived from Chinese hamsters, a system commonly used for cytotoxicity studies, and (b) rat hepatocytes isolated from male Wistar rats. After treatment, cell viability was determined by 3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2H-tetrazolium bromide reduction (MTT reduction), total acid content and neutral red uptake assays. To evaluate V79 cell viability, different concentrations of semi-synthetic crotonin were incubated with the cells. To evaluate the antiulcerogenic effects of semi-synthetic crotonin (50, 100 and 200 mg/kg), we used the models of gastric ulcer induced by ethanol/HCl, stress, indomethacin/bethanechol, and ethanol in male Swiss mice and male Wistar rats. The substance had an IC50 = 500 muM in the neutral red uptake and MTT reduction tests and an IC50 = 200 muM in the nucleic acid content test. With regard to hepatocyte viability after treatment with semi-synthetic crotonin at different concentrations, semi-synthetic crotonin had an IC50 = 10-500 muM in the nucleic acid content and MTT reduction tests and an IC50 = 120 muM in the neutral red uptake test. In another experiment, V79 cells were incubated with the metabolites produced by hepatocytes treated with different concentrations of semi-synthetic crotonin. After a 4-h incubation, semi-synthetic crotonin had an IC50 = 500 muM in the MTT reduction and neutral red uptake tests and an IC50 = 370 muM in nucleic acid content test. The substance had significant antiulcerogenic activity in all models studied, suggesting the presence of a possible antisecretory effect combined with a cytoprotective effect. For this reason, the effect of semi-synthetic crotonin was also evaluated on biochemical parameters of gastric juice and gastric wall mucus, both obtained from pylorus-ligated mice. No significant differences were observed in these parameters between semi-synthetic crotonin-treated and control animals. The results obtained with semi-synthetic crotonin are promising, with a significant preventive effect against gastric ulcer induced by different agents. Our data also show that semi-synthetic crotonin was less toxic than dehydrocrotonin and that the cytotoxic effects decreases with the time that isolated hepatocytes were in culture. (C) 2003 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of three new derivatives from dehydrocrotonin (DHC-compound I) on gastric damage indifferent animal models including gastric ulceration induced by a necrotic agent and hypothermic restrained-stress was studied: compound 11 (produced by reducing the cyclohexenone moiety of DHC with NaBH4): compound III (produced by reducing the carbonyls with LiAlH4); and compound IV (produced by transforming the lactone moiety into an amide). Their structures were confirmed on the basis of chemical and physicochemical evidence. When previously administered (p.o.) at a dose of 100 mg/kg, compound II significantly (P < 0.01) reduced gastric injury induced by HCl/ethanol (78%) and indomethacin (88%) better than did reference compound 1 (48 and 43%, respectively). But the anti-ulcerogenic activity of compound II was completely abolished by the stress-induced ulcer. Reduction of carbonyls with LiAlH4 (compound 111) caused decreased activity, markedly when no protective effect in any of the models was applied (P > 0.05). However, compound IV, in which the lactone moiety was changed into an amide. when administered at the same dose (100 mg/kg, p.o.), was more effective. The presence of a lactone moiety or Michael acceptor is probably essential for the anti-ulcerogenic effect of these compounds. (C) 2003 Elsevier B.V. Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, we evaluated the involvement of rat ventral prostate smooth muscle cells (SMC) in secretory activity and whether this function is modulated after castration. Cell morphology was examined at both light and electron microscopy levels and the organelles involved in secretory function were labeled by the zinc-iodide-osmium (ZIO) method at the ultrastructural level and their volume density was determined by stereology. Castration resulted in marked changes of the SMC, which adopted a spinous aspect and abandoned the layered arrangement observed in the prostates of non-castrated rats. The volume density of ZIO reactive organelles increased progressively after castration, reaching significantly higher levels 21 days after castration, Since previous studies have demonstrated that SMC express SMC markers (even 21 days after castration) and are able to respond to adrenergic stimulation, we concluded that differentiated SMC are able to shift from a predominantly contractile to a more synthetic phenotype without changing their differentiation status. (c) 2005 International Federation for Cell Biology. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)