152 resultados para Stiffness reduction
Resumo:
Fiber reinforced epoxy composites are used in a wide variety of applications in the aerospace field. These materials have high specific moduli, high specific strength and their properties can be tailored to application requirements. In order to screening optimum materials behavior, the effects of external environments on the mechanical properties during usage must be clearly understood. The environmental action, such as high moisture concentration, high temperatures, corrosive fluids or ultraviolet radiation (UV), can affect the performance of advanced composites during service. These factors can limit the applications of composites by deteriorating the mechanical properties over a period of time. Properties determination is attributed to the chemical and/or physical damages caused in the polymer matrix, loss of adhesion of fiber/resin interface, and/or reduction of fiber strength and stiffness. The dynamic elastic properties are important characteristics of glass fiber reinforced composites (GRFC). They control the damping behavior of composite structures and are also an ideal tool for monitoring the development of GFRC's mechanical properties during their processing or service. One of the most used tests is the vibration damping. In this work, the measurement consisted of recording the vibration decay of a rectangular plate excited by a controlled mechanism to identify the elastic and damping properties of the material under test. The frequency amplitude were measured by accelerometers and calculated by using a digital method. The present studies have been performed to explore relations between the dynamic mechanical properties, damping test and the influence of high moisture concentration of glass fiber reinforced composites (plain weave). The results show that the E' decreased with the increase in the exposed time for glass fiber/epoxy composites specimens exposed at 80 degrees C and 90% RH. The E' values found were: 26.7, 26.7, 25.4, 24.7 and 24.7 GPa for 0, 15, 30, 45 and 60 days of exposure, respectively. (c) 2005 Springer Science + Business Media, Inc.
Resumo:
The environmental factors, such as humidity and temperature, can limit the applications of composites by deteriorating the mechanical properties over a period of time. Environmental factors play an important role during the manufacture step and during composite's life cycle. The degradation of composites due to environmental effects is mainly caused by chemical and/or physical damages in the polymer matrix, loss of adhesion at the fiber/matrix interface, and/or reduction of fiber strength and stiffness. Composite's degradation can be measure by shear tests because shear failure is a matrix dominated property. In this work, the influence of moisture in shear properties of carbon fiber/epoxy composites ( laminates [0/0](s) and [0/90](s)) have been investigated. The interlaminar shear strength (ILSS) was measured by using the short beam shear test, and Iosipescu shear strength and modulus (G(12)) have been determinated by using the Iosipescu test. Results for laminates [0/0](s) and [0/90](s), after hygrothermal conditioning, exhibited a reduction of 21% and 18% on the interlaminar shear strenght, respectively, when compared to the unconditioned samples. Shear modulus follows the same trend. A reduction of 14.1 and 17.6% was found for [0/0](s) and [0/90](s), respectively, when compared to the unconditioned samples. Microstructural observations of the fracture surfaces by optical and scanning electron microscopies showed typical damage mechanisms for laminates [0/0](s) and [0/90](s).
Resumo:
Block diagrams and signal-flow graphs are used to represent and to obtain the transfer function of interconnected systems. The reduction of signal-flow graphs is considered simpler than the reduction of block diagrams for systems with complex interrelationships. Signal-flow graphs reduction can be made without graphic manipulations of diagrams, and it is attractive for a computational implementation. In this paper the authors propose a computational method for direct reduction of signal-flow graphs. This method uses results presented in this paper about the calculation of literal determinants without symbolic mathematics tools. The Cramer's rule is applied for the solution of a set of linear equations, A program in MATLAB language for reduction of signal-flow graphs with the proposed method is presented.
Resumo:
This letter presents an alternative approach for reducing the total real power losses by using a continuation method. Results for two simple test systems and for the IEEE 57-bus system show that this procedure results in larger voltage stability margin. Besides, the reduction of real power losses obtained with this procedure leads to significant money savings and, simultaneously, to voltage profile improvement. Comparison between the solution of an optimal power flow and the proposed method shows that the latter can provide near optimal results and so, it can be a reasonable alternative to power system voltage stability enhancement.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Engineers often face the challenge of reducing the level of vibrations experienced by a given payload or those transmitted to the support structure to which a vibrating source is attached. In order to increase the range over which vibrations are isolated, soft mounts are often used in practice. The drawback of this approach is the static displacement may be too large for reasons of available space for example. Ideally, a vibration isolator should have a high-static stiffness, to withstand static loads without too large a displacement, and at the same time, a low dynamic stiffness so that the natural frequency of the system is as low as possible which will result in an increased isolation region. These two effects are mutually exclusive in linear isolators but can be overcome if properly configured nonlinear isolators are used. This paper is concerned with the characterisation of such a nonlinear isolator comprising three springs, two of which are configured to reduce the dynamic stiffness of the isolator. The dynamic behaviour of the isolator supporting a lumped mass is investigated using force and displacement transmissibility, which are derived by modelling the dynamic system as a single-degree-of-freedom system. This results in the system dynamics being approximately described by the Duffing equation. For a linear isolator, the dynamics of the system are the same regardless if the source of the excitation is a harmonic force acting on the payload (force transmissibility) or a harmonic motion of the base (displacement transmissibility) on which the payload is mounted. In this paper these two expressions are compared for the nonlinear isolator and it is shown that they differ. A particular feature of the displacement transmissibility is that the response is unbounded at the nonlinear resonance frequency unless the damping in the isolator is greater than some threshold value, which is not the case for force transmissibility. An explanation for this is offered in the paper. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The development of an experimental switching stiffness device fcr shock isolation is presented. The system uses magnetic forces to exert a restoring force, which results in an effective stiffness that is used to isolate a payload. When the magnetic force is turned on and off, a switchable stiffness is obtained. Characterization of the physical properties of the device is presented. They are estimated in terms of the percentage stiffness change and effective damping ratio when switched between two constant stiffness states. Additionally, the setup is used to implement a control strategy to reduce the shock response and minimize residual vibration. The system was found to be very effective for shock isolation. The response is reduced by around 50 percent compared with passive isolation showing good correlation with theoretical predictions, and the effective damping ratio in the system following the shock was increased from about 4.5 percent to 13 percent. (c) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: Avaliar o número de podócitos e espessamento da membrana basal glomerular (MBG) em ratos diabéticos com e sem controle glicêmico com 6 e 12 meses da indução. MÉTODOS: 100 ratos Wistar com 200-300g compuseram 6 grupos: Normal (N6, N12 - 25 animais) Diabético (D6,D12 - 25 animais) e diabético tratado com insulina 1,8 a 3,0 U/Kg e acarbose misturada a ração (50g para cada 100g de ração) (DT6 e DT12 - 25 animais). Aloxana foi ministrada via endovenosa na dose de 42mg/Kg. Peso, ingestão hídrica e diurese de 24 horas e glicemia e glicosúria foram determinados antes da inoculação, 7 e 14 dias após e mensalmente. No 14ª dia foi iniciado o tratamento. Três grupos de animais (N6, D6 e DT6) foram sacrificados no 6° mês e três grupos (N12, D12 e DT12), no 12ª mês sendo o tecido renal processado para estudo à microscopia eletrônica. RESULTADOS: A glicemia dos animais DT6 e DT12 diferiram significativamente, dos ratos D6 e D12, e não diferiram dos grupos N6 e N12. O número de podócitos do grupo DT6 não diferiu de N6 e D6 (mediana=11); o número de podócitos de DT12 (mediana=11) diferiu de D12 (mediana=8) e não diferiu de N12 (mediana=11). O espessamento da MBG de D6 (0,18 micrômetros) foi menor que D12 (0,29 micrômetros); de DT6 (0,16 micrômetros) foi menor que D6 (0,18 micrômetros) e de DT12 (0,26 micrômetros) foi menor que D12 (0,29 micrômetros). CONCLUSÃO: O controle da hiperglicemia preveniu o espessamento da MBG na nefropatia diabética aloxânica precoce (6 meses) e tardia (12 meses), e a diminuição do número de podócitos.
Resumo:
Os autores padronizaram métodos para a avaliação da atividade da glicose-6-fosfato desidrogenase e glutationa redutase. O princípio geral do primeiro método baseou-se na formação de metahemoglobina pelo nitrito de sódio, seguido da estimulação da via das pentoses pelo azul de metileno. Foram estudados 46 indivíduos adultos, sendo 23 do sexo masculino e 23 do feminino, não deficientes em glicose-6-fosfato desidrogenase (G6PD), com idades variando entre 20 e 30 anos. Os resultados revelaram que a redução da metahemoglobina pelo azul de metileno para sangue total, foram de 154.50 e 139.90 mg/min (p<0.05) respectivamente para o sexo masculino e feminino. Para hemácias lavadas os valores foram de 221.10 e 207.85 mg/min (n.s.) respectivamente. Estas observações permitiram concluir que ao se empregar hemácias lavadas e 0.7 g% de concentração de nitrito de sódio, por um lado não houve diferença entre os sexos e por outro, abreviou o tempo de leitura da quantidade residual de metahemoglobina para 90 minutos. A avaliação da atividade da glutationa redutase foi feita baseado no fato de que a cistamina (agente tiol) liga-se aos grupos SH da hemoglobina formando complexos. Estes complexos são revertidos pela ação da glutationa redutase, ocorrendo conjuntamente nesta reação a redução da metahemoglobina. Foram estudados 32 indivíduos adultos, sendo 16 do sexo masculino e 16 do feminino, não deficientes em G6PD, com idades variando entre 20 e 30 anos. Os resultados revelaram valores de redução da metahemoglobina pela cistamina de 81.27 e 91.13 mg/min (p<0.01) respectivamente para o sexo masculino e feminino. Estas observações permitiram concluir que o emprego de hemácias lavadas e 0.1 molar de concentração de cistamina torna possível a leitura da quantidade residual de metahemoglobina aos 180 minutos de incubação. A atividade da glutationa redutase avaliada por meio da redução da metahemoglobina pela cistamina, foi estudada em 14 indivíduos do sexo feminino antes e após o tratamento com 10 mg por dia de riboflavina durante 8 dias. Os resultados foram de 73.69 e 94.26 mg/min (p<0.01) antes e após o tratamento. Estas observações permitiram concluir que a oferta de riboflavina, mesmo para indivíduos normais, aumenta a atividade da glutationa redutase. Foram ainda avaliados 3 indivíduos da raça negra e deficientes em G6PD, sendo 2 do sexo masculino e 1 do feminino. Houve ativação parcial da G6PD e glutationa redutase, sendo estas alterações mais intensas nos indivíduos do sexo masculino. Considerando-se a raça e as características laboratoriais observadas, foi possível sugerir que a deficiência em G6PD verificada é do tipo Africano, bem como, permitiu considerar os indivíduos do sexo feminino coin o sendo heterozigoto para esta deficiência. Por fim, a análise dos resultados em seu conjunto permitiu concluir que os métodos propostos se mostraram eficientes para avaliar a atividade da G6PD e glutationa redutase. Esta última é dependente da via das pentoses, geradora de NADPH e da riboflavina, vitamina precursora de FAD.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to evaluate the clinical and radiographic outcome in 8 dogs of surgical reduction of congenital humeroulnar luxation by using the transarticular pin. Five cases were bilateral and 3 were unilateral, for a total of 13 elbows. The treatment was performed in animals between 45 and 150 days of age. Articular stabilization was achieved by using a transarticular pin driven from the caudal aspect of the olecranon into the body of the humerus or into the distal condyle and distal metaphysis of the humerus. The follow-up period was between 1 and 19 months. There were 5 postsurgical reluxations, 3 related to the insertion of the pin into the humeral condyle and 3 related to the insertion into the humeral body. These animals needed further surgery. Six animals showed near normal return to limb function and 2 had lameness. We conclude that the use of the transarticular pin is an effective and simple method for the treatment of humeroulnar congenital elbow luxation.