169 resultados para Stereoscopic cameras


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Based on analyses of high-speed video recordings of cloud-to-ground lightning in Brazil and the USA, the characteristics of positive cloud-to-ground (+CG) leaders are presented. The high frame rates permitted the average, 2-dimensional speeds of development along the paths of the channels to be resolved with good accuracy. The values range from 0.3 to 6.0 x 10(5) ms(-1) with a mean of 2.7 x 10(5) ms(-1). Contrary to what is usually assumed, downward +CG leader speeds are similar to downward -CG leader speeds. Our observations also show that the speeds tend to increase by a factor of 1.1 to 6.5 as they approach the ground. The presence of short duration, recoil leaders (RLs) during the development of positive leaders reveal a highly branched structure that is not usually recorded when using conventional photographic and video cameras. The existence of the RLs may help to explain observations of UHF-VHF radiation during the development of +CG flashes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONTEXTO: A cirurgia videolaparoscópica (CVL) vem evoluindo como alternativa cirúrgica menos invasiva para o tratamento da doença aterosclerótica oclusiva aorto-ilíaca e do aneurisma da aorta abdominal. Poucos estudos avaliaram objetivamente a curva de aprendizado com essa técnica em cirurgia vascular. OBJETIVO: Avaliar objetivamente os tempos e a evolução de cada passo cirúrgico e demonstrar a exeqüibilidade dessa técnica. MÉTODOS: Entre outubro 2007 e janeiro de 2008, dois cirurgiões vasculares iniciantes na CVL operaram, após cursos e treinamentos, seis porcos consecutivos, com dissecção aórtica e interposição de um enxerto de dácron em um segmento da aorta infra-renal abdominal, com técnica totalmente laparoscópica. RESULTADOS: Todos os tempos cirúrgicos foram decrescentes ao longo do estudo, apresentando redução de 45,9% no tempo total de cirurgia, 85,8% no tempo de dissecção da aorta, 81,2% na exposição da aorta, 55,1% no clampeamento total, 71% na confecção da anastomose proximal e 64,9% na anastomose distal. CONCLUSÃO: O presente estudo mostrou que os resultados técnicos satisfatórios da CVL vascular ocorreram somente após longa curva de aprendizado, que foi decrescente ao longo do tempo, à medida que aumentou a experiência e vivência com os materiais e com a visão não-estereoscópica. Essa técnica pode ser realizada com perfeição por cirurgiões vasculares desde que façam cursos especializados, com treinamento em simuladores e animais, e desde que busquem constante aprimoramento a fim de conseguir resultados similares aos obtidos com a cirurgia convencional.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Investigam-se imagens e significados sobre experiências vivenciadas por pacientes no processo de atendimento/tratamento em uma enfermaria, visando problematizar questões éticas no cotidiano das práticas de saúde, que possam contribuir para refletir, no espaço da formação profissional, sobre situações que, muitas vezes, se naturalizam pela urgência da rotina. O trabalho consistiu em entregar câmaras fotográficas a cinco pacientes acamados, internados em uma Enfermaria de Ortopedia de um hospital universitário, no segundo semestre do ano de 2001, para que registrassem, pela fotografia, experiências que vivenciavam na condição de pacientes, procurando responder às perguntas: o que significa estar na cama sem poder sair dela? O que é bom e o que é ruim em sua rotina na Enfermaria? Buscando compreender o material pela ótica dos pacientes, apresenta-se aqui parte da experiência registrada e relatada. Os resultados obtidos apontam que entre as maiores dificuldades enfrentadas pelos pacientes entrevistados estão a dependência, gerando constrangimento e desconforto, e a falta de informação, gerando insegurança e ampliando a dependência.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to compare the micromorphology of CVD diamond tips coupled to ultrasound with conventional high speed diamond tips after cavity preparations, and to measure the width and depth of the cavities obtained. Two hundred bovine teeth were divided into 20 subgroups. Each of the diamond tips (10 CVD and 10 conventional) were used to prepare 10 standardized cavities, using an apparatus that controlled the time (t: 27 s), speed (5.3 mm/s) and load (0.012 KGF) of the tip against the teeth during preparation. The unused and the used (after one, five and 10 preparations) tips were analyzed by scanning electronic microscopy. The images were randomly assessed by 3 examiners with regard to the presence or absence of micromorphologic alterations. Cavity measurements were made after visualization under a stereoscopic microscope. Cavity widths and depths were analyzed by the ANOVA Factorial test (p < 0.05). The CVD diamond tips presented less wear than the conventional tips after all the cavity preparations performed, but produced shallower cavities that were equivalent in width to those made by conventional tips after the fifth preparation. CVD diamond tips may be suggested as an alternative to conventional diamond tips due to their conservative preparation and greater longevity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to assess the influence of cleaning pits and fissures with on aluminum oxide air abrasion system on the detection of occlusal caries in primary teeth using laser fluorescence (LF) and visual examination. Methods. The sample comprised 65 pit and fissure sites on extracted primary teeth suspected to be carious. The sites were submitted to 2 visual examinations (examiner JAR) and 2 LF readings (examiner TMV). Next, the occlusal surfaces were air-abraded and re-examined thereafter using both methods. The teeth were sectioned, and the histological analysis of the sites with a stereoscopic magnifying lens at X32 magnification was used as the gold standard Results. Cohen's kappa statistic for LF and visual examination were, respectively, 0.282/0.884 before and 0.896/0.905 after air abrasion. LF showed a sensitivity of 0.28 increasing to 0.49 and 0 specificity of 0.50 increasing to 0.92. Visual examination showed sensitivity of 0.78 and specificity of 0.73. Both increased after air abrasion. Conclusion: The findings suggest that cleaning pits and fissures with aluminum oxide air abrasion increased the accuracy of LF and visual examination for detection of occlusal caries in primary teeth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Statement of problem. When clinical fractures of the ceramic veneer on metal-ceramic prostheses can be repaired, the need for remake may be eliminated or postponed. Many different ceramic repair materials are available, and bond strength data are necessary for predicting the success of a given repair system.Purpose. This study evaluated the shear bond strength of different repair systems for metal-ceramic restorations applied on metal and porcelain.Material and methods. Fifty cylindrical specimens (9 X 3 mm) were fabricated in a nickel-chromium alloy (Vera Bond 11) and 50 in feldspathic porcelain (Noritakc). Metal (M) and porcelain (P) specimens were embedded in a polyvinyl chloride (PVC) ring and received I of the following bonding and resin composite repair systems (n=10): Clearfil SE Bond/Clearfil AP-X (CL), Bistite II DC/Palfique (BT), Cojet Sand/Z100 (Q), Scotchbond Multipurpose Plus/Z100 (SB) (control group), or Cojet Sand plus Scotchbond Multipurpose Plus/Z100 (CJSB). The specimens were stored in distilled water for 24 hours at 37 degrees C, thermal cycled (1000 cycles at 5 degrees C to 55 degrees C), and stored at 37 degrees C for 8 days. Shear bond tests between the metal or ceramic specimens and repair systems were performed in a mechanical testing machine with a crosshead speed of 0.5 mm/min. Mean shear bond strength values (MPa) were submitted to 1-way ANOVA and Tukey honestly significant difference tests (alpha=.05). Each specimen was examined under a stereoscopic lens with X 30 magnification, and mode of failure was classified as adhesive, cohesive, or a combination.Results. on metal, the mean shear bond strength values for the groups were as follows: MCL, 18.40 +/- 2.88(b); MBT, 8.57 +/- 1.00(d); MCJ, 25.24 +/- 3.46(a); MSB, 16.26 +/- 3.09(bc); and MCJSB, 13.11 +/- 1.24(c). on porcelain, the mean shear bond strength values ofeach group were as follows: PCL, 16.91 +/- 2.22(b); PBT, 18.04 +/- 3.2(ab); PCJ, 19.54 +/- 3.77(ab); PSB, 21.05 +/- 3.22(a); and PCJSB, 16.18 +/- 1.71(b). Within each substrate, identical superscript letters denote no significant differences among groups.Conclusions. The bond strength for the metal substrate was significantly higher using the Q system. For porcelain, SB, Q, and BT systems showed the highest shear bond strength values, and only SB was significantly different compared to CL and CJSB (P <.05).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives:Microleakage is a pre-stage of debonding between hard chairside relines and denture base acrylic resins. Therefore, it is important to assess them with regard to the longevity of the relined denture. This study investigated the effect of thermal cycling on the microleakage at the interface of three hard chairside reline resins and three denture base resins.Material and methods:Rectangular bars (12 mm x 3 mm x 3 mm) of Lucitone 550, Acron MC and QC 20 were made and relined with Kooliner, Tokuyama Rebase Fast II and Ufi Gel Hard, Lucitone 550, Acron MC and QC 20 resins. Specimens were divided into one control and two test groups (n = 10). In specimens of the control group, the microleakage was performed after the reline procedure. In Test Group 1, the specimens were stored for 24 h in distilled water at room temperature and in Test Group 2; the specimens were thermal cycled from 5 to 55 degrees C for 5000 cycles with a 30-s dwell time. Subsequently, all specimens were immersed in 50% silver nitrate solutions for 24 h. All specimens were sectioned longitudinally into three fractions and the lateral sections were examined (n = 20). Silver nitrate stain penetration was examined under a stereoscopic lens with x30 magnification, and the images were captured. Leica Qwin image analysis software was used to determine microleakage at the interface of the materials. Data were analysed using the Kruskal-Wallis test at a 95% level of significance.Results:For all cycles, there were no statistically significant differences between thermal cycled and non-thermal cycled groups (p > 0.05).Conclusion:It can be concluded that thermal cycling had no effect on the microleakage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: This study evaluated the bond strength of luting systems for bonding glass fiber posts to root canal dentin. The hypothesis tested was that there are no differences in bond strength of glass fiber posts luted with different cement systems.Methods: Forty bovine incisors were randomly assigned to five different resin cement groups (n=8). After endodontic treatment and crown removal, translucent glass fiber posts were bonded into the root canal using five different luting protocols (self-cured cement and etch-and-rinse adhesive system; dual-cured cement and etch-and-rinse adhesive system; self-cured cement and self-etch adhesive system; dual-cured cement and self-etch adhesive system; and dual-cured self-adhesive cement). Push-out bond strength was evaluated at three different radicular levels: cervical, middle, and apical. The interface between resinous cement and the post was observed using a stereoscopic microscope.Results: Analysis of variance showed a statistically significant difference among the cements (p<0.05) and the root canal thirds (p<0.05). The self-adhesive resinous cement had lower values of retention.Conclusions: The resin cements used with etch-and-rinse and self-etch adhesive systems seem to be adequate for glass fiber post cementation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate in vitro the degree of marginal leakage in Class V cavities involving the cementoenamel junction. Cavities were 4 rum wide and 2 mm deep. The specimens received dentin pretreatment (37% phosphoric acid) followed by the Single Bond (3M) adhesive system application. The 40 specimens were then divided into four groups: Group I (control); Group 2 (Nd:YAG laser at 120 mJ/pulse, frequency of 10 Hz, power of 1.2 W); Group 3 (Nd:YAG laser at 140 mJ/pulse, frequency of 10 Hz, power of 1.4 W); Group 4 (Nd:YAG laser at 160 mJ/pulse, frequency of 10 Hz, power of 1.6 W). The cavities were restored with Z100 composite resin (3M) and light cured at 300-600 mW/cm(2) light intensity. Specimens were thermocycled to 500 cycles from 2-50 degrees C. After that, they were dried and sealed with nail varnish, respecting 1 mm around the restorations, and immersed in 0.5% methylene blue solution for 4 h. After this period, the teeth were rinsed, dried, sectioned, and analyzed in a stereoscopic loupe. The highest leakage scores were considered for each specimen. The results were statistically analyzed by the analysis of variance (ANOVA) Kruskal-Wallis test to the 5% level. For both the enamel and cementum, there was a decrease in marginal leakage with the application of laser energy; no significant differences were observed for Groups 2, 3, and 4. The results also showed a smaller tendency to marginal leakage on the cementum than on the enamel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neste artigo é proposto um método semiautomático para extração de rodovias combinando um estereopar de imagens aéreas de baixa resolução com um poliedro gerado a partir de um modelo digital do terreno (MDT). O problema é formulado no espaço-objeto através de uma função objetivo que modela o objeto 'rodovia' como uma curva suave e pertencente a uma superfície poliédrica. A função objetivo proposta depende também de informações radiométricas, que são acessadas no espaço-imagem via relação de colinearidade entre pontos da rodovia no espaço-objeto e os correspondentes nos espaços imagem do estereopar. A linha poligonal que melhor modela a rodovia selecionada é obtida por otimização no espaço-objeto da função objetivo, tendo por base o algoritmo de programação dinâmica. O processo de otimização é iterativo e dependente do fornecimento por um operador de uma aproximação inicial para a rodovia selecionada. Os resultados obtidos mostraram que o método é robusto frente a anomalias existentes ao longo das rodovias, tais como obstruções causadas por sombras e árvores.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tropical fishes like Leporinus macrocephalus Garavello & Britski, 1988 (piauçu) and the hybrid tambacu (Piaractus mesopotamicus Holmberg, 1887 pacu male x Colossoma macropomum Cuvier, 1818 tambaqui female) were experimentally infected with four inocula of trophonts of Ichthyophthirius multifiliis Fouquet, 1876 (Protozoa, Ciliophora) and the infection level was evaluated. Each one of twelve experimental units consisted of a tank with 200 liters of water and two specimens of each kind of fish. The following treatments were designed to each tank, in triplicate: 8, 16,32 and 64 trophonts. After 8 days of exposure the fishes were killed and the number of trophonts was counted at a stereoscopic microscope. This assay showed to be feasible at tropical conditions and was able to show that tambacu was more susceptiblc than piauçu.