52 resultados para Simulations Monte Carlo de la chimie de trajectoires
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Física - IFT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The huge demand for procedures involving ionizing radiation promotes the need for safe methods of experimentation considering the danger of their biological e ects with consequent risk to humans. Brazilian's legislation prohibits experiments involving this type of radiation in humans through Decree 453 of Ministry of Health with determines that such procedures comply with the principles of justi cation, optimization and dose limitation. In this line, concurrently with the advancement of available computer processing power, computing simulations have become relevant in those situations where experimental procedures are too cost or impractical. The Monte Carlo method, created along the Manhattan Project duringWorldWar II, is a powerful strategy to simulations in computational physics. In medical physics, this technique has been extensively used with applications in diagnostics and cancer treatment. The objective of this work is to simulate the production and detection of X-rays for the energy range of diagnostic radiology, for molybdenum target, using the Geant4 toolkit. X-ray tubes with this kind of target material are used in diagnostic radiology, speci cally in mammography, one of the most used techniques for screening of breast cancer in women. During the simulations, we used di erent models for bremsstrahlung available in physical models for low energy, in situations already covered by the literature in earlier versions of Geant4. Our results show that although the physical situations seems qualitatively adequate, quantitative comparisons to available analytical data shows aws in the code of Geant4 Low Energy source
Resumo:
Monte Carlo simulations of water-tetrahydrofuran (THF) mixtures were performed in the isothermal-isobaric ensemble (NPT) at T = 298 K and p = 1 atm. The interaction energy was calculated using the TIP4P model for water and a five-site united atom representation for the THF molecule. The potential energy surfaces for water-THF interactions were obtained by using combining rules and the original potential functions used for pure liquids. Theoretical values obtained for the average interaction energy as a function of concentration are in good agreement with available experimental data. Results from the partitioning of the total interaction energy into water-water, water-THF and THF-THF contributions are presented. These results are useful to distinguish between the quantitative contributions of these molecular interactions to the energetic behavior of the water-THF mixing process. The radial distribution functions for HW-OTHF and OW-OTHF site-site interactions show the salient features of hydrogen-bonded liquids. Comparison of the average number of water-water complexes interacting through hydrogen bonding in water-THF and water-methanol mixtures shows an enhancement of the water-water coordination number in a THF rich environment. © 1995.
Resumo:
Pós-graduação em Física - IFT
Resumo:
Foram realizados quatro estudos de simulação para verificar a distribuição de inversas de variáveis com distribuição normal, em função de diferentes variâncias, médias, pontos de truncamentos e tamanhos amostrais. As variáveis simuladas foram GMD, com distribuição normal, representando o ganho médio diário e DIAS, obtido a partir da inversa de GMD, representando dias para se obter determinado peso. em todos os estudos, foi utilizado o sistema SAS® (1990) para simulação dos dados e para posterior análise dos resultados. As médias amostrais de DIAS foram dependentes dos desvios-padrão utilizados na simulação. As análises de regressão mostraram redução da média e do desvio-padrão de DIAS em função do aumento na média de GMD. A inclusão de um ponto de truncamento entre 10 e 25% do valor da média de GMD reduziu a média de GMD e aumentou a de DIAS, quando o coeficiente de variação de GMD foi superior a 25%. O efeito do tamanho dos grupos nas médias de GMD e DIAS não foi significativo, mas o desvio-padrão e CV amostrais médios de GMD aumentaram com o tamanho do grupo. em virtude da dependência entre a média e o desvio-padrão e da variação observada nos desvios-padrão de DIAS em função do tamanho do grupo, a utilização de DIAS como critério de seleção pode diminuir a acurácia da variação. Portanto, para a substituição de GMD por DIAS, é necessária a utilização de um método de análise robusto o suficiente para a eliminação da heterogeneidade de variância.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Analytical and Monte Carlo approaches to evaluate probability distributions of interruption duration
Resumo:
Regulatory authorities in many countries, in order to maintain an acceptable balance between appropriate customer service qualities and costs, are introducing a performance-based regulation. These regulations impose penalties-and, in some cases, rewards-that introduce a component of financial risk to an electric power utility due to the uncertainty associated with preserving a specific level of system reliability. In Brazil, for instance, one of the reliability indices receiving special attention by the utilities is the maximum continuous interruption duration (MCID) per customer.This parameter is responsible for the majority of penalties in many electric distribution utilities. This paper describes analytical and Monte Carlo simulation approaches to evaluate probability distributions of interruption duration indices. More emphasis will be given to the development of an analytical method to assess the probability distribution associated with the parameter MCID and the correspond ng penalties. Case studies on a simple distribution network and on a real Brazilian distribution system are presented and discussed.
Resumo:
Polyampholyte copolymers containing both positive and negative monomers regularly dispersed along the chain were studied. The Monte Carlo method was used to simulate chains with charged monomers interacting by screened Coulomb potential. The neutral polyampholyte chains collapse due to the attractive electrostatic interactions. The nonneutral chains are in extended conformations due to the repulsive polyelectrolyte effects that dominate the attractive polyampholyte interactions. The results are in good agreement with experiment.
Resumo:
Regulatory authorities in many countries, in order to maintain an acceptable balance between appropriate customer service qualities and costs, are introducing a performance-based regulation. These regulations impose penalties, and in some cases rewards, which introduce a component of financial risk to an electric power utility due to the uncertainty associated with preserving a specific level of system reliability. In Brazil, for instance, one of the reliability indices receiving special attention by the utilities is the Maximum Continuous Interruption Duration per customer (MCID). This paper describes a chronological Monte Carlo simulation approach to evaluate probability distributions of reliability indices, including the MCID, and the corresponding penalties. In order to get the desired efficiency, modern computational techniques are used for modeling (UML -Unified Modeling Language) as well as for programming (Object- Oriented Programming). Case studies on a simple distribution network and on real Brazilian distribution systems are presented and discussed. © Copyright KTH 2006.
Resumo:
Proton radiation therapy is a precise form of radiation therapy, but the avoidance of damage to critical normal tissues and the prevention of geographical tumor misses require accurate knowledge of the dose delivered to the patient and the verification of his position demand a precise imaging technique. In proton therapy facilities, the X-ray Computed Tomography (xCT) is the preferred technique for the planning treatment of patients. This situation has been changing nowadays with the development of proton accelerators for health care and the increase in the number of treated patients. In fact, protons could be more efficient than xCT for this task. One essential difficulty in pCT image reconstruction systems came from the scattering of the protons inside the target due to the numerous small-angle deflections by nuclear Coulomb fields. The purpose of this study is the comparison of an analytical formulation for the determination of beam lateral deflection, based on Molière's theory and Rutherford scattering with Monte Carlo calculations by SRIM 2008 and MCNPX codes. © 2010 American Institute of Physics.