167 resultados para Silicone membrane


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A clinical review of three potentially severe fungal diseases, which are characterized in many cases by mucosal involvement, is presented. They are paracoccidioidomycosis, histoplasmosis, and mucormycosis. Mucosal involvement for paracoccidioidomycosis and rhinocerebral mucormycosis is frequent. Thus, oral involvement may provide early clue for diagnosis. In paracoccidioidomycosis, the mucosal lesion classically shows superficial ulcers with granular appearance and hemorrhagic points, usually on lips, palate, and jugal mucosa. In mucormycosis, necrosis of the palate followed for purulent discharge is a hallmark of rhinocerebral disease. Treatment with amphotericin B desoxycholate or the new second-generation triazoles is highly efficacious.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Capsular contracture is the main complication related to breast silicone implants, and its prevention remains a medical challenge. The authors present experimental research examining the effect of external ultrasound on the formation and contracture of peri-implant capsules.Methods In this study, 42 male Wistar rats had a 2-mm smooth surface implant placed in a dorsal submuscular pocket. They then were separated into ultrasound'' and control'' groups that received repeated external applications either with or without the ultrasound power on. Ultrasound applications were given three times a week for a period of 90 days. After that, both groups were housed under the same conditions with no application scheduled. Five animals of each group, killed at 30, 60, 90, and 180 days, had their implants removed along with the capsule, which received a special histologic preparation via annular sectioning that provided wide circumferential observation of the capsular tissue. Sections were stained with hematoxylin/eosin stain, Masson's trichrome stain, and Pricrosirius Red stain for regular microscopic evaluation under normal and polarized light.Results Histologic data showed that capsules from the ultrasound and control groups had statistically significant differences. Ultrasound application developed a capsular architecture similar to that shown within textured silicone implants, and its effect had an early definition with subsequent stabilization.Conclusion The authors conclude that early and repeated external ultrasound application enhances the thickness, cellular count, and vascularity of smooth silicone capsular tissue, whereas it diminishes the pattern of parallel orientation of collagen fibers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o efeito do laser de baixa intensidade sobre a contração da pseudocápsula que ocorre ao redor de implantes de silicone. MÉTODOS: 60 ratos machos divididos em dois grupos receberam implante de silicone. Grupo I: implante no subcutâneo da região dorsal, sem tratamento após a cirurgia; Grupo II: animais receberam sete sessões de irradiação com laser de baixa intensidade após o implante. Trinta, 60 e 180 dias após a cirurgia, foi feita a tonometria dos implantes, em seguida, os animais foram sacrificados, removendo-se o material de estudo que foi preparado para exame histológico, avaliando-se morfometricamente a espessura da pseudocápsula e a reação inflamatória. A análise estatistica pela técnica da Análise de Variância e Teste de Tukey (P<0.0 5). RESULTADOS: Pressões significativamente menores foram encontradas nos animais do grupo Grupo II. O estudo histológico não mostrou diferença significativa entre os grupos, destacando-se apenas maior quantidade de vasos intumescidos no Grupo II. A espessura da pseudocápsula foi menor no Grupo II. CONCLUSÃO: O laser de baixa intensidade altera o processo de reparação tecidual ao redor dos implantes, sugerindo que o mesmo possa ser útil para a modelação das contraturas que se estabelecem ao redor dos implantes de silicone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar e comparar a biocompatibilidade de esferas de silicone gelatinosas e rígidas em cavidades evisceradas de coelhos. MÉTODOS: Trinta coelhos tiveram o olho direito eviscerado com implantação de esferas de silicone gelatinosas (Grupo I) ou rígidas (Grupo II). Foi realizada avaliação clínica diária, ultrassonografia da cavidade orbitária, análise histológica e morfométrica da pseudocápsula que se formou ao redor dos implantes aos 7, 30 e 90 dias após a cirurgia, com avaliação estatística dos resultados. RESULTADOS: Houve boa integração das esferas com os tecidos orbitários e semelhança de resposta tecidual com ambas as esferas. Duas esferas de silicone gelatinosas e uma rígida extruíram. A pseudocápsula que se formou ao redor das esferas gelatinosas foi mais organizada, com espessura e reação inflamatória menores que a observada nas esferas rígidas. CONCLUSÕES: Esferas de silicone gelatinosas e rígidas tiveram boa integração tecidual em cavidades evisceradas de coelhos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Barrier materials as cellulose membranes are used for guided tissue repair. However, it is essential that the surrounding tissues accept the device. The present study histologically evaluated tissue reaction to a microbial cellulose membrane after subcutaneous implantation in mice. Furthermore, the interaction between mesenchymal stem cells and the biomaterial was studied in vitro to evaluate its ability to act as cellular scaffold for tissue engineering.Methods: Twenty-five Swiss Albino mice were used. A 10 x 10 mm cellulose membrane obtained through biosynthesis using Acetobacter xylinum bacteria was implanted into the lumbar subcutaneous tissue of each mouse. The mice were euthanatized at seven, 15, 30, 60, and 90 days, and the membrane and surrounding tissues were collected and examined by histology.Results: A mild inflammatory response without foreign body reaction was observed until 30 days post-surgery around the implanted membrane. Polarized microscopy revealed that the membrane remained intact at all evaluation points. Scanning electron microscopy of the cellulose membrane surface showed absence of pores. The in vitro evaluation of the interaction between cells and biomaterial was performed through viability staining analysis of the cells over the biomaterial, which showed that 95% of the mesenchymal stem cells aggregating to the cellulose membrane were alive and that 5% were necrotic. Scanning electron microscopy showed mesenchymal stem cells with normal morphology and attached to the cellulose membrane surface.Conclusion: The microbial cellulose membrane evaluated was found to be nonresorbable, induced a mild inflammatory response and may prove useful as a scaffold for mesenchymal stem cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to describe the presence of osteopontin (OPN) in canine seminal plasma and sperm membranes. A pool of seminal plasma and sperm membrane extract from 30 dogs was used. Polyacrylamide electrophoresis gels were performed and the bands were transferred to nitrocellulose paper and Western blot was undertaken using an antibody anti-OPN. Two and 12 bands were marked in the seminal plasma (77.2 and 15.6 kDa) and sperm membrane extracts (70.6-26.6 kDa), respectively. However, from 12 marked bands in the sperm membrane extract, only three (46.4, 37.7 and 36.5 kDa) were strongly marked. We conclude that, seminal plasma and sperm membranes from dogs contain different isoforms of OPN; yet, further studies will be necessary to determine their function in this species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. Amniotic membrane transplantation (AMT) has been used as a graft or as a dressing in ocular surface reconstruction, facilitating epithelization, maintaining normal epithelial phenotype, and reducing inflammation, vascularization, and scarring. The corneal transparency is due, at least in part, to the arrangement in orthogonal lamellae of collagen fibrils, surrounded by proteoglycans (PGs). These PGs regulate fibrilogenesis, the matrix assembly, and ultimately the corneal transparency. The purpose of the present study was to investigate the effects of AMT upon the corneal PGs after severe limbal injury.METHODS. Experiments were performed on the right corneas of 22 New Zealand female albino rabbits, and their left corneas were used as matched controls. These animals were divided into 3 groups: G1 (n = 10): total peritomy and keratolimbectomy, followed by application of 0.5 M NaOH; G2 (n = 10): submitted to the same trauma as G1, and treated by AMT; G3: no trauma, only AMT (n = 2). The right corneas of G2 and G3 were covered by DMSO 4 cryopreserved human amniotic membrane, fixed by interrupted 9-0 mononylon sutures, with its stromal face toward the ocular surface. After 7 or 30 days, the corneas were removed and PGs were extracted.RESULTS. Normal corneas contained approximately 9 mg of PGs per gram of dry tissue. AMT on intact cornea (G3) did not cause any changes in the concentration of PGs. In contrast, injured corneas contained much less PGs, both on the seventh and on the 30th day posttrauma. The PG concentration was even lower in injured corneas treated by AMT. This decrease was due almost exclusively to dermatan sulfate PGs, and the structure of dermatan sulfate was also modified, indicating changes in the biosynthesis patterns.CONCLUSIONS. Although beneficial effects have been observed on clinical observation and concentration of soluble proteins after AMT, the normal PG composition of cornea was not attained, even 30 days postinjury, indicating that the normal ocular surface reconstruction, if possible, is a long-term process. (Eur J Ophthalmol 2010; 20: 290-9)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To describe the early healing processes around the implants installed after elevation of the sinus mucosa applying the lateral access technique without the use of grafting material.Material and methods: Immediately after the elevation of the maxillary sinus Schneiderian membrane by the lateral approach in eight monkeys, implants were installed without the use of grafting material. The healing of the tissue around the implants was evaluated after 4, 10, 20 and 30 days. Ground sections were prepared and analyzed histologically.Results: After 4 days of healing, the formation of coagulum and provisional matrix was documented within the elevated area. At 10-day interval, sprouts of woven bone were in continuity with the parent bone, and partly in contact with the implant surface at the base of the augmented area. While bone-to-implant contact increased after 20 and 30 days, the area underneath the Schneiderian membrane appeared reduced in volume and condensed toward the apex of the implants. The sinus mucosa was to some extent collapsed onto the implant surface and on the newly formed bone.Conclusions: The void initially occupied by the coagulum after sinus membrane elevation shrank substantially during the observation period. A lack of influence of the Schneiderian membrane in bone formation apical to implants was documented in the early phase of healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The failure of facial prostheses is caused by limitations in the properties of existing materials, especially the biocompatibility. This study aimed to evaluate the biocompatibility of maxillofacial silicones in subcutaneous tissue of rats. Thirty Wistar rats received subcutaneous implants of 3 maxillofacial silicone elastomers (LIM 6050, MDX 4-4210, and industrial Silastic 732 RTV). A histomorphometric evaluation was conducted to analyze the biocompatibility of the implants. Eight areas of 60.11 mm(2) from the surgical pieces were analyzed. Mesenchymal cells, eosinophils, and foreign-body giant cells were counted. Data were submitted to analysis of variance and Tukey test. Initially, all implanted materials exhibited an acceptable tissue inflammatory response, with tissue reactions varying from light to moderate. Afterward, a fibrous capsule around the silicone was observed. The silicones used in the current study presented biocompatibility and can be used for implantation in both medical and dental areas. Their prosthetic indication is conditioned to their physical properties. Solid silicone is easier to adapt and does not suffer apparent modifications inside the tissues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the color stability of MDX4-4210 maxillofacial elastomer with opacifier addition submitted to chemical disinfection and accelerated aging.Materials and Methods: Ninety specimens were obtained from Silastic MDX4-4210 silicone. The specimens were divided into three groups (n = 30): Group I: colorless, Group II: barium sulfate opacifier, Group III: titanium dioxide opacifier. Specimens of each group (n = 10) were disinfected with effervescent tablets, neutral soap, or 4% chlorhexidine gluconate. Disinfection was conducted three times a week for 2 months. Afterward, the specimens were submitted to different periods of accelerated aging. Color evaluation was carried out after 60 days (disinfection period) and after 252, 504, and 1008 hours of accelerated aging, using a reflection spectrophotometer. Color alterations were calculated by the CIE L*a*b* system. Data were analyzed by three-way ANOVA and Tukey test (alpha = 0.05).Results: Group II exhibited the lowest color change, whereas Group III the highest (p < 0.05), regardless of the chemical disinfection and accelerated aging periods.Conclusion: Opacifier addition, chemical disinfection, and accelerated aging procedures affected the color stability of the maxillofacial silicone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)