207 resultados para Silicone elastomer
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The failure of facial prostheses is caused by limitations in the properties of existing materials, especially flexibility and durability. Therefore, this study evaluated the Shore A hardness of silicone used for fabrication of facial prostheses, Silastic MDX4-4210, according to the influence of storage period, daily disinfection, and 2 types of pigmentation. Thirty specimens were fabricated and divided in 3 groups: colorless, pigmented with makeup, and pigmented with iron oxide. Analysis of results was assessed on a Shore A hardness meter immediately, 6 months, and 1 year after fabrication of specimens, following the guidelines of the American Society for Testing and Materials. The hardness values were statistically analyzed by the Tukey test. The silicone exhibited an increase in hardness with time. However, the hardness was stable from 6 months to 1 year. It was concluded that the silicone is within the values of Shore A hardness reported in the literature, regardless of the storage period, pigmentation, and chemical disinfection.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Neste estudo observamos a reação tecidual após implantação de próteses de silicone associadas à poliglactina 910. Telas de borracha de silicone com 1,5 x 1,5cm de diâmetro e 0,7mm de espessura, polifenestradas, foram implantadas no subcutâneo do dorso de ratos.Dois grupos foram observados, no primeiro apenas telas fenestradas eram implantadas, no segundo as fenestrações das telas eram preenchidas com fios de poliglactina 910. Os animais foram observados por 30, 60 e 90 dias quando eram sacrificados e as telas mais o tecido adjacente ressecados. Não se observou diferenças na quantidade de fibras colágenas entre os subgrupos de um mesmo grupo e ou quando comparados com os subgrupos do grupo em estudo. No grupo controle, onde se usou apenas as telas fenestradas de silicone houve uma diferença significante entre as fibras reticulares, em maior número nos grupos de 30 e 60 dias de observação, quando comparadas ao grupo de 90 dias. A poliglactina 910 associada ao silicone não alterou o número de fibras do tecido conjuntivo, contadas nas fenestrações das telas.
Análise histológica e morfométrica da área cruenta tratada com membrana de silicone: estudo em ratos
Resumo:
Background. Thin study evaluated the effects of a silicone membrane on the treatment of the raw flesh area in wounds.METHODS. The experimental study was carried out with 30 male Wistar rats divided into three groups: in the G(G) group, the raw area was treated with gauze, in the G(H) group with homograft, and in the G(S) group with a silicone membrane. Animals were sacrificed at fourteen days of postoperative. The studied attributes were body mass variation, histological study quantifed by morphometric analysis evaluating the number of neovessels, fibroblasts, collagen fibers, leucocytes, monocytes; and using a micrometric ruler measurement of the raw area thickness. Data were then submitted to statistical analysis.RESULTS. There was no significant difference between the animals' mass (p=0.0685). Predominance of neovessels (p<0.01), fibroblasts (p<0.001) and thickness of the raw flesh were observed in G(S) animals. There was predominance of leucocytes (p<0.021) and monocytes (p<0.0001) in G(H) animals. Also, no significant difference between the groups as for collagen fibers (p=0.0536) was observed.CONCLUSION. The silicone membrane promoted granulation tissue with a large number of neovessels, fibroblasts and greater thickness.
Resumo:
In this work it was investigated the effect of the exposure to different plasmas on the wettability of silicone samples. We have observed that oxygen. argon, and hydrogen glow discharges are quite effective in reducing the water contact angle of such polymer. However, indifferently to efficiency of the treatment, practically all the modified surfaces recovered great part of their original hydrophobicity. We have investigated this hydrophobic recovery using surface energy measurements and theoretical simulations based on the exponential decay of the population of polar groups on the surface. According to our results such recovery can be attributed to the decrease of polar species at the interface water-polymer surface.
Resumo:
The accuracy of impressions that transfer the relationship of the implant to the metal framework of the prosthesis continues to be a problem. This study was designed to evaluate the accuracy of the transfer process under variable conditions with regard to implant analog angulations, impression materials, and techniques. Replicas (n = 60) of a metal matrix (control) containing four implants at 90°, 80°, 75°, and 65° in relation to the horizontal surface were obtained by using three impression techniques: T1 - indirect technique with conical copings in closed trays; T2 - direct technique with square copings in open trays; and T3 - square copings splinted with autopolymerizing acrylic resin; and four elastomers: P-polysulfide; I-polyether; A-addition silicone; and Z-condensation silicone. The values of the implant analog annulations were assessed by a profilometer to the nearest 0.017°, then submitted to analysis of variance for comparisons at significance of 5% (P < .05). For implant analog at 90°, the material A associated with T2 and material Z with T3 behaved differently (P < .05) from all groups. At 80°, all materials behaved differently (P < .01) with T1. At 75°, when T1 was associated, materials P and A showed similar behavior, as well as materials I and Z; however, P and A were different from I and Z (P < .01). When T3 was associated, all experimental groups behaved differently among them (P < .01). At 65°, the materials P and Z behaved differently (P < .01) from the control group with T1, T2, and T3; the materials I and A behaved differently from the control group (P < .01) when T1 and T2, respectively, were associated. The more perpendicular the implant analog annulation is in relation to the horizontal surface, the more accurate the impression. The best materials were material I and A and the most satisfactory technique was technique 3.
Resumo:
The aim of the present study was to evaluate the effect of disinfection and accelerated ageing on the dimensional stability and detail reproduction of a facial silicone with different types of nanoparticle. A total of 60 specimens were fabricated with Silastic MDX 4-4210 silicone and they were divided into three groups: colourless and pigmented with nanoparticles (make-up powder and ceramic powder). Half of the specimens of each group were disinfected with Efferdent tablets and half with neutral soap for 60 days. Afterwards, all specimens were subjected to accelerated ageing. Both dimensional stability and detail reproduction tests were performed after specimen fabrication (initial period), after chemical disinfection, and after accelerated ageing periods (252, 504 and 1008 hours). The dimensional stability test was conducted using AutoCAD software, while detail reproduction was analysed using a stereoscope magnifying glass. Dimensional stability values were statistically evaluated by analysis of variance (ANOVA) followed by Tukey's test (p < 0.01). Detail reproduction results were compared using a score. Chemical disinfection and also accelerated ageing affected the dimensional stability of the facial silicone with statistically significant results. The silicone's detail reproduction was not affected by these two factors regardless of nanoparticle type, disinfection and accelerated ageing. © 2012 Informa UK, Ltd.
Resumo:
Several dermocosmetic bases even without active substances, can increase the cutaneous hydration, resulting in a beneficial effect to the skin. The evidence and interpretation of possible hydration effect of formulations in the skin can be carried through by means of histopathological and histomorphometrical evaluation, a time that allows the analysis of the epithelial tissue, of dermis and also of the cellular characteristics. The objective of this research was to evaluate the skin hydration after exposition to the aqueous and hydroalcoholic bases and silicone emulsion. Swines had areas submitted to treatments during 15 days with three different formulations (F1 - aqueous gel, F2 - hydroalcoholic gel and F3 - silicone emulsion). By means of histometric and histopathological techniques were gotten the thickness of the epidermis and stratum corneum. Comparison of means was done using ANOVA followed by the Tukey test. The F1 provoked significant increase in the thickness of the epidermis. The formulaton F2 provoked significant reduction in the thickness of the epidermis and stratum corneum. F3 not presented significant difference in this structures. According to the study, the type of base chosen intervenes with the skin hydration.
Resumo:
Breast implants are medical devices that are used to augment breast size or to reconstruct the breast following mastectomy or to correct a congenital abnormality. Breast implants consist of a silicone outer shell and a filler (most commonly silicone gel or saline). Approximately 5 to 10 million women worldwide have breast implants. Histomorphometric study to evaluate the biological tissue compatibility of silicone implants suitable for plastic surgery and the adverse effects and risks of this material. Thirty Wistar white rats received subcutaneous implants and the revestiment of silicone gel Silimed ®®, and randomized into six groups of five animals each, according to the type of implanted material and the time of sacrifice. Eight areas of 60.11mm2 corresponding to the obtained surgical pieces were analyzed, counting mesenchymal cells, eosinophils, and foreign body giant cells, observing an acceptable biocompatibility in all implants, for subsequent statistical analysis by Tukey test. Silicone gel showed inflammation slightly greater than for other groups, with tissue reactions varying from light to moderate, whose result was the formation of a fibrous capsule around the material, recognized by the organism as a foreign body. Despite frequent local complications and adverse outcomes, this research showed that the silicone and top layer presented an acceptable chronic inflammatory reaction, which did not significantly differ from the control group. In general, it is possible to affirm that silicone gel had acceptable levels of biocompatibility, confirmed the rare presence of foreign body giant cells, and when of the rupture, formed a fibrous capsule around the material, separating the material of the organism. © AVICENA 2013.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)