92 resultados para SENSITIVE DETERMINATION


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The determination of leukocyte alkaline phosphatasd (LAP) is used as an aid to diagnose many diseases in the laboratory. For example, it can be used to distinguish chronic myeloid leukemia (CML) from other myeloproliferative disorders (particularly myelofibrosis and polycythemia) and leukemoid reactions (LR). Traditionally, this test is performed with the use of subjective cytochemical assays that assign a score to the level of LAP. Here we present a nonsubjective, quantitative, sensitive, and inexpensive chemiluminescent technique that determines LAP based on the commercial reagent Immulite (R) (AMPPD). To validate this methodology, intact leukocytes obtained from 32 healthy subjects, nine CML patients, and nine LR patients were submitted to the optimized protocol. By measuring the light emission elicited by four concentrations of neutrophils, we were able to estimate the activity of LAP per cell (the slope of the curve obtained by linear regression). A high linear correlation was found between the chemiluminescent result (slope) and the cytochemical score. The slope for healthy individuals ranged between 0.61 and 8.49 (10(-5) mV.s/cell), with a median of 2.04 (10(-5) mV.s/cell). These results were statistically different from those of CML patients (range = 0.07-1.75, median = 0.79) and LR patients (range = 3.84-47.24, median 9.58; P < 0.05).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A sensitive, accurate, reliable and easy method was developed for the quantification of oxamniquine in capsules using high-performance liquid chromatography (HPLC) with UV detection. This technique provided conditions for the separation of the active ingredient from the dosage form by extraction in methanol. Isocratic reversed phase chromatography was performed using methanol, water, and triethanolamine (60:40:0.099, v/v/w) (System C) or methanol, acetonitrile, water and formic acid (40:30:30:0.083, v/v/w) (System D) as mobile phase, a stainless steel column (125 x 4 mm i.d., 5 mum) filled with LiChrospher 100 RP-18 (Merck), column temperature of 28 +/- 2 degreesC and detection at 260 nm. The calibration curves were linear over a wide concentration range (1.0-20.0 mug ml(-1) of oxamniquine) to the Systems C and D with good correlation factor (0.9990 and 0.9982, respectively). The average content obtained were 100.1 +/- 1.5% (System C) and 102.4 +/- 0.8% (System D). The presence of lactose, starch, magnesium stearate and sodium laurylsulphate did not interfere in the results of the analysis. The above findings showed the proposed method to be both simple and added advantage of allowing for fast analysis. (C) 2001 Elsevier B.V. B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A visible light spectrophotometric method is described for them determination of sparfloxacin in tablets. The procedure is based on the complexation of bromothymol blue 0.5% and sparfloxacin to form a compound of yellow colour with maximum absorption at 385 nm. The Lambert-Beer law was obeyed in the concentration range of 2-12 mg/l. The present study describes a sensitive and accurate method for the determination of the concentration of sparfloxacin in tablets. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rapid, accurate, and sensitive high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of ceftazidime in pharmaceuticals. The method validation parameters yielded good results and included range, linearity, precision, accuracy, specificity, and recovery. The excipients in the commercial powder for injection did not interfere with the assay. Reversed-phase chromatography was used for the HPLC separation on a Waters C18 (WAT 054275; Milford, MA) column with methanol-water (70 + 30, v/v) as the mobile phase pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 245 nm. The calibration graph for ceftazidime was linear from 50.0 to 300.0 mu g/mL. The values for interday and intraday precision (relative standard deviation) were < 1 %. The results obtained by the HPLC method were calculated statistically by analysis of variance. We concluded that the HPLC method is satisfactory for the determination of ceftazidime in the raw material and pharmaceuticals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A sensitive flow-injection (FI) procedure with spectrophotometric detection in a micellar medium is proposed for the determination of novalgin. The method is based on the instantaneous formation of a red-orange product (lambda(max) = 510 nm) after the reaction between novalgin and p-dimethylaminocinnamaldehyde (p-DAC) in a dilute acid medium. The sensitivity of this reaction was increased by a factor of 5.6 in the presence of sodium dodecyl sulfate (SDS). Experimental design methodologies were used to optimize the chemical and FI variables. The calibration curve was linear in the range of 1.45 x 10(-6) to 2.90 x 10(-5) mol L-1 with an excellent correlation coefficient (r = 0.9999). The detection limit was 1.31 x 10(-7) mol L-1 (n = 20, RSD = 2.0%). No interferences were observed from the common excipients. The results obtained by the proposed method were favorably compared with those given by the iodometric reference method at 95% confidence level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a simple, fast and sensitive method to determine selenium in samples of feces and of fish feed by graphite furnace atomic absorption spectrometry (GFAAS) through the direct introduction of slurries of the samples into the spectrometer's graphite tube. The limits of detection (LOD) and quantification (LOQ calculated for 20 readings of the blank of the standard slurries (0.50% m/v of feces or feed devoid of selenium) were 0.31 mu g 1(-1) and 1.03 mu g 1(-1), respectively, for the standard feces slurries and 0.35 mu g 1(-1) and 1.16 mu g 1(-1), respectively, for the standard feed slurries. The proposed method was applied in studies of bioavailability of selenium in different fish feeds and the results proved consistent with that obtained from samples mineralized by acid digestion using the microwave oven. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a simple, fast and sensitive method to determine chromic oxide (used as a biological marker of fish feed) in samples of fish feces by GFAAS through the direct introduction of slurries of the samples into the spectrometer's graphite tube. The standard samples of feces and of fish feed containing 0.10-1.00 mg kg(-1) of Cr2O3 were pre-frozen for I min in liquid nitrogen and then ground a cryogenic mill for 2 min, which reduced the samples' grain size to less than 60 mu m. The standard slurries were prepared by mixing 20 mg of standard samples of fish feed or feces with I mL of a solution containing 0.05% (v/v) of Triton X-100 and 0.50% (v/v) of suprapure HNO3 directly in the spectrometer's automatic sampling glass. The final concentrations of Cr2O3 present in the standard slurries were 2, 4, 8, 16 and 20 mu g L-1. After sonicating the mixture for 20s, 10 mu L of standard slurries were injected into the graphite tube, whose internal wall was lined with a metallic palladium film that acted as a permanent chemical modifier. The limits of detection (LOD) and quantification (LOQ) calculated for 20 readings of the blank of the standard slurries (2%, m/v of feces or feed devoid of minerals) were 0.81 and 2.70 mu g L-1 of Cr2O3 for the standard feces slurries, 0.84 and 2.83 mu g L-1 of Cr2O3 for the standard feed slurries. The proposed method was applied in studies of nutrient digestibility of different fish feeds and its results proved compatible with the results obtained from samples pre-mineralized by acid digestion. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a simple, fast, and sensitive method to determine zinc in samples of feces and fish feed by electrothermal atomic absorption spectrometry through the direct introduction of slurries of the samples into the spectrometer's graphite tube. The procedure is based on the injection of 10 mu L of an acidified aqueous solution containing 0.50% w/v of feces or feed and 0.50% v/v HNO(3) into graphite tube. The limits of detection and quantification calculated for 20 readings of the blank of the standard slurries (0.50% w/v of feces or feed devoid of zinc) were 0.04 and 0.13 mu g L(-1) for the standard feces slurries and 0.05 and 0.17 mu g L(-1) for the standard feed slurries. The proposed method was applied in studies of digestibility of zinc in different fish feeds, and their results proved compatible with that obtained from samples mineralized by acid digestion using microwave oven.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)