47 resultados para SATURABLE ABSORBER


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and Objectives - Inhalational anesthetics have a mild analgesic effect. The reduction of alveolar concentration (MAC) of potent volatile anesthesics by increasing plasma concentrations of opioids is desired in inhalational anesthesia. The purpose of this study was to determine the role of sufentanil in reducing sevoflurane and isoflurane MAC. Methods - Thirty eight adult patients of both genders, physical status ASA I or II, submitted to major abdominal procedures were randomly allocated into two groups. Group I (n = 24) received inahalational anesthesia with sevoflurane and Group II (n = 14) received inhalational anesthesia with isoflurane, both diluted in a mixture of N2O (1 liter) and O2 (0.5 liter). A semi-closed system with CO2 absorber and partial reinhalation was used. Ventilation was mechanically controlled. Sufentanil infusion was administered aiming at obtaining 0.5 ng.ml-1 of plasma concentration. Sufentanil plasma concentration was previously calculated by a computer software. End-tidal concentrations were obtained through a gas analyzer and measured at 15 minutes (M1), 30 minutes (M2), 60 minutes (M3), 90 minutes (M4) and 120 minutes (M5). Systolic and diastolic blood pressure (SBP and DBP) and heart rate (RR) were measured during the same periods with the addition of M0 (pre-anesthetic period). Hourly consumption of the inhalational anesthetic agent (IAC), extubation time (ET = time between admission to the recovery room and extubation) and stay in the post anesthesia recovery room (PA-RR) were also measured. Results - Type and duration of surgeries were similar for both groups. There were no statistically significant differences in MAC, SBP, DBP, RR, IAC, TE and PA-RR between groups. Systolic blood pressure in group I (sevoflurane) showed differences among periods F = 3.82 p < O.05; (M2 = M3)(M4 = M5) and M1 had a intermediate value. MAC in group I showed differences among periods F = 9.0 p < 0.05; M1 < M3. MAC in group II also showed differences among periods F = 13.03 p < O.05; M1 < (M2,M3,M4,M5). Conclusions - Both groups had similar behavior when associated to sufentanil in major abdominal surgeries. Group II showed a higher cardiac and circulatory stability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To determine the effect of heat and moisture exchange (HME) on the tracheobronchial tree (TBT) using a unidirectional anesthesic circuit with or without CO2 absorber and high or low fresh gas flow (FGF), in dogs. Methods: Thirty-two dogs were randomly allocated to four groups: G1 (n = 8) valvular circuit without CO2 absorber and high FGF (5 L·min-1); G2 (n = 8) as G1 with HME; G3 (n = 8) circuit with CO2 absorber with a low FGF (1 L·min-1); G4 (n = 8) as G3 with HME. Anesthesia was induced and maintained with pentobarbital. Tympanic temperature (TT), inhaled gas temperature (IGT), relative (RH) and absolute humidity (AH) of inhaled gas were measured at 15 (control), 60, 120 and 180 min of controlled ventilation. Dogs were euthanized and biopsies in the areas of TBT were performed by scanning electron microscopy. Results: The G2 and G4 groups showed the highest AH (>20 mgH2O·L-1) and G1 the lowest (< 10 mgH2O·L-1) and G3 was intermediate (<20 mgH2O·L-1) (P < 0.01). There was no difference of TT and IGT among groups. Alterations of the mucociliary system were greatest in G1, least in G2 and G4, and intermediate in G3. Conclusion: In dogs, introduction of HME to a unidirectional anesthetic circuit with/without CO2 absorber and high or low FGF preserved humidity of inspired gases. HME attenuated but did not prevent alterations of the mucociliary system of the TBT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mechanisms involved in the absorption of amino acids and oligopeptides are reviewed regarding their implications in human feedings. Brush border and basolateral membranes are crossed by amino acids and di-tripeptides by passive (facilitated or simple diffusion) or active (Na + or H + co-transporters) pathways. Active Na +-dependent system occurs mainly at brush border and simple diffusion at basolateral, both membranes have the passive facilitated transport. Free-amino acids use either passive or active transport systems whereas di-tripeptides do mainly active (H + co-transporter). Brush border have distinctive transport system for amino acids and di-tripeptides. The former occurs mainly by active Na + dependency whereas the later is active H +-dependent with little affinity for tetra or higher peptides. Free amino acids are transported at different speed by saturable, competitive carriers with specificity for basic, acidic or neutral amino acids. Di and tripeptides have at least two carriers both electrogenic and H +-dependent. The basolateral membrane transport of amino acids is mostly by facilitated diffusion while for di-tripeptides it is an active anion exchange associated process. The main regulation of amino acids and di-tripeptide transport is the presence o substrate at the mucosal membrane with higher the substrate higher the absorption. Di and tripeptides are more efficiently absorbed than free amino acids which in turns are better absorbed than oligopeptides. So di-tripeptides result in better N-retention and is particularly useful in cases of lower intestinal absorption capacity. The non-absorbed peptides are digested and fermented by colonic bacteria resulting short-chain fatty acids, dicarboxylic acids, phenolic compounds and ammonia. Short-chain fatty acid provides energy for colonocytes and bacteria and the ammonia not fixed by bacteria returns to the liver for ureagenesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coated purpose of homogeneous distribution as a second phase is introduced in magnetic systems. Yttrium iron garnet (YIG) shows special interest as magnetic dye, microwave absorber, and magnetic fluids when heterocoagulated by other material. Surface and interface magnetic properties are intimately connected with the new properties of the silica on YIG system. Néel first introduced the concept of surface anisotropy, and Chen et al. developed a model that describes the anisotropy effects at the boundary surface particle, which was applied in this work. Spherical YIG particles were prepared by coprecipitation method and coated with silica using the tetraethylorthosilicate (TEOS) hydrolysis process. The silica-YIG boundary was investigated by transmission electron microscopy. Hysteresis loops comparatively show the profile of the naked and silica-covered YIG particles. The surface anisotropies were calculated using the Chen et al. approach. Indeed, in heterocoagulation systems, the surface anisotropy is a result of the interface symmetry breaking, as observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the last decades there was a great development in the study of control systems to attenuate the harmful effect of natural events in great structures, as buildings and bridges. Magnetorheological fluid (MR), that is an intelligent material, has been considered in many proposals of project for these controllers. This work presents the controller design using feedback of states through LMI (Linear Matrix Inequalities) approach. The experimental test were carried out in a structure with two degrees of freedom with a connected shock absorber MR. Experimental tests were realized in order to specify the features of this semi-active controller. In this case, there exist states that are not measurable, so the feedback of the states involves the project of an estimator. The coupling of the MR damper causes a variation in dynamics properties, so an identification methods, based on experimental input/output signal was used to compare with the numerical application. The identification method of Prediction Error Methods - (PEM) was used to find the physical characteristics of the system through realization in modal space of states. This proposal allows the project of a semi-active control, where the main characteristic is the possibility of the variation of the damping coefficient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The pCT deals with relatively thick targets like the human head or trunk. Thus, the fidelity of pCT as a tool for proton therapy planning depends on the accuracy of physical formulas used for proton interaction with thick absorbers. Although the actual overall accuracy of the proton stopping power in the Bethe-Bloch domain is about 1%, the analytical calculations and the Monte Carlo simulations with codes like TRIM/SRIM, MCNPX and GEANT4 do not agreed with each other. A tentative to validate the codes against experimental data for thick absorbers bring some difficulties: only a few data is available and the existing data sets have been acquired at different initial proton energies, and for different absorber materials. In this work we compare the results of our Monte Carlo simulations with existing experimental data in terms of reduced calibration curve, i.e. the range - energy dependence normalized on the range scale by the full projected CSDA range for given initial proton energy in a given material, taken from the NIST PSTAR database, and on the final proton energy scale - by the given initial energy of protons. This approach is almost energy and material independent. The results of our analysis are important for pCT development because the contradictions observed at arbitrary low initial proton energies could be easily scaled now to typical pCT energies. © 2010 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Here, a simplified dynamical model of a magnetically levitated body is considered. The origin of an inertial Cartesian reference frame is set at the pivot point of the pendulum on the levitated body in its static equilibrium state (ie, the gap between the magnet on the base and the magnet on the body, in this state). The governing equations of motion has been derived and the characteristic feature of the strategy is the exploitation of the nonlinear effect of the inertial force associated, with the motion of a pendulum-type vibration absorber driven, by an appropriate control torque [4]. In the present paper, we analyzed the nonlinear dynamics of problem, discussed the energy transfer between the main system and the pendulum in time, and developed State Dependent Riccati Equation (SDRE) control design to reducing the unstable oscillatory movement of the magnetically levitated body to a stable fixed point. The simulations results showed the effectiveness of the (SDRE) control design. Copyright © 2011 by ASME.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper the dynamics of the ideal and non-ideal Duffing oscillator with chaotic behavior is considered. In order to suppress the chaotic behavior and to control the system, a control signal is introduced in the system dynamics. The control strategy involves the application of two control signals, a nonlinear feedforward control to maintain the controlled system in a periodic orbit, obtained by the harmonic balance method, and a state feedback control, obtained by the state dependent Riccati equation, to bring the system trajectory into the desired periodic orbit. Additionally, the control strategy includes an active magnetorheological damper to actuate on the system. The control force of the damper is a function of the electric current applied in the coil of the damper, that is based on the force given by the controller and on the velocity of the damper piston displacement. Numerical simulations demonstrate the effectiveness of the control strategy in leading the system from any initial condition to a desired orbit, and considering the mathematical model of the damper (MR), it was possible to control the force of the shock absorber (MR), by controlling the applied electric current in the coils of the damper. © 2012 Foundation for Scientific Research and Technological Innovation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective was to evaluate the internal quality of white-shelled consume eggs, sanitized or not, stored under different packaging conditions at room temperature. It was used 300 eggs, distributed in a completely randomized experimental design in a 3×2×4+1 factorial arrangement, three packaging conditions (PVC film, partial vacuum, partial vacuum with oxygen gas absorber), storage period (7, 14, 21 and 28 days), sanitized or not, and control (fresh eggs), with four repetitions. At the end of each period the analysis were performed. Partial vacuum condition was able to maintained Haugh unit, and promoted the best results for yolk index. The weight maintenance was better when packaged under vacuum, with or without O2 sachets absorbers. Lower values of water activity were obtained in eggs packed in PVC film, and when the sanitation was performed. It can be concluded that the internal egg quality decreases with storage time sharper in the eggs packed in PVC film, because vacuum has preserved some features of them. With sanitation, the storage conditions of eggs in PVC film should be improved because its internal quality decrease was greatest.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have prepared heavy metal oxide glasses containing metallic copper nanoparticles with promising nonlinear optical properties which were determined by Z-scan and pump-probe measurements using femtosecond laser pulses. For the wavelengths within the plasmon band, we have observed saturable absorption and response times of 2.3 ps. For the other regions of the spectrum, reverse saturable absorption and lifetimes shorter than 200 fs were verified. The nonlinear refractive index is about 2.0 × 10-19 m2/W from visible to telecom region, thus presenting an enhancement effect at wavelengths near the plasmon and Cu+2 d-d band. © 2013 Springer Science+Business Media New York.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Delayed feedback (DF) control is a well-established technique to suppress single frequency vibration of a non-minimum phase system. Modal control is also a well-established technique to control multiple vibration modes of a minimum phase system. In this paper these techniques are combined to simultaneously suppress multiple vibration modes of a non-minimum phase system involving a small time delay. The control approach is called delayed resonant feedback (DRF) where each modal controller consists of a modal filter to extract the target mode signal from the vibration response, and a phase compensator to account for the phase delay of the mode. The methodology is first discussed using a single mode system. A multi-mode system is then studied and experimental results are presented to demonstrate the efficacy of the control approach for two modes of a beam. It is shown that the system behaves as if each mode under control has a dynamic vibration absorber attached to it, even though the actuator and the sensor are not collocated and there is a time delay in the control system. © 2013 IOP Publishing Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Flexible magnetic membranes with high proportion of magnetite were successfully prepared by previous impregnation of the never dried bacterial cellulose pellicles with ferric chloride followed by reduction with sodium bisulfite and alkaline treatment for magnetite precipitation. Membranes were characterized by Raman spectroscopy, Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), vibrating magnetometer, field emission scanning electron microscopy (FEG-SEM) and impedance spectroscopy. Microwave properties of these membranes were investigated in the X-band (8.2 to 12.4 GHz). FEG-SEM micrographs show an effective coverage of the BC nanofibers by Fe 3O4 nanoparticles. Membranes with up to 75% in weight of particles have been prepared after 60 min of reaction. Magnetite nanoparticles in the form of aggregates well adhered to the BC fibers were observed by SEM. The average crystal sizes of the magnetic particles were in the range of 10 ± 1 to 13 ± 1 nm (estimated by XRD). The magnetic particles in the BC pellicles presented superparamagnetic behavior with a saturation magnetization in the range of 60 emu g- 1 and coercive force around 15 Oe. These magnetic pellicles also displayed high electrical permittivity and a potential application as microwave absorber materials. © 2013 Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)