51 resultados para SAT


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The voltammetric determination of rutin in 0.04 mol l(-1) B-R buffer (pH 4.0) by square wave voltammograms (+0.41 V vs. Ag/AgCl(sat.)) at a poly glutamic acid modified glassy carbon electrode was found to be several orders of magnitude lower than that on a bare glassy carbon electrode. Rutin can be preconcentrated on the films of poly glutamic acid and presented linear relationship from concentration of 7 x 10(-7) to 1 x 10(-5) mol l(-1) in 0.04 mol l(-1) B-R buffer pH 4.0. The method was successfully applied to the determination of rutin in pharmaceutical formulation without any pretreatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diode-pumped Yb-doped glass lasers have received considerable attention for applications such as high-power beam production or femtosecond pulses generation. In this paper, we evaluate the laser potential of three different glass families doped with Yb3+ : alkali lead fluorborate (PbO-PbF2-B2O3), heavy metal oxide (Bi2O3-PbO-Ga2O3) and niobium tellurite (TeO2-Nb2O5-K2O-Li2O). Spectroscopic properties were studied for the samples and calculations of the minimum laser pump intensity (I-min), saturation fluence (U-sat) and the theoretical limit of peak power (P-max) are also presented. A comparison of laser properties of these three different glasses and their importance is shown and analyzed. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The malate dehydrogenase (MDH) and ascorbate oxidase were immobilized independently, onto silanized controlled porous silica and packed in a tygon tube. The reactors were inserted in the flow system, and the malic acid was determined by measurement of NADH produced by enzymatic reaction. The NADH was reoxidized in a wall jet cell that consisted of spectrographic graphite, Ag/AgCl, KCl(sat), and steel needle as work, reference, and counter electrodes, respectively. The current intensities were measured at 390 mV. The malate calibration curve shows a linear range from 5.0 x 10(-6) to 1.0 x 10(-4) molL(-1), the lifetime was 40 analyses, after that a decrease of 20% on the response is observed. Three different citric juices were analyzed and a good correlation between the proposed method and spectrophotometric commercial kit were obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to examine if there is any developmental change in the coupling between visual information and trunk sway in infants as they acquire the sitting position. Twenty-four infants distributed in four groups (6-, 7-, 8-, and 9-month-old) were sat inside a moving room that oscillated back and forward at frequencies of 0.2 and 0.5 Hz. The results revealed that trunk sway matched to the moving room at both frequencies but did not differ among the four age groups. Coherence and gain revealed that the coupling was weaker at 0.2 than at 0.5 Hz. Relative phase showed that at 0.2 Hz, infants were swaying with no lag but at 0.5 Hz they were lagging the room. These results showed that the coupling between visual information and trunk sway in infants varies with the visual stimulus but does not change as infants acquire the sitting position. © 2001 Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, electrochemical oxidation of albendazole (ABZ) was carried out using a glassy carbon-rotating disk electrode. Development of electroanalytical methodology for ABZ quantification in pharmaceutical formulations was also proposed by using linear sweep voltammetric technique. Electrochemical oxidation is observed for ABZ at E 1/2 = 0.99:V vs. Ag/AgCl sat, when an anodic wave is observed. Kinetic parameters obtained for ABZ oxidation exhibited a standard heterogeneous rate constant for the electrodic process equal to (1.51 ± 0.07) ± 10 -5:cm:s -1, with a αn a value equal to 0.76. Limiting current dependence against ABZ concentration exhibited linearity on 5.0 ± 10 -5 to 1.0 ± 10 -2:mol:l -1 range, being obtained a detection limit of 2.4 ± 10 -5:mol:l -1. Proposed methodology was applied to ABZ quantification in pharmaceutical formulations. © 2005 Elsevier SAS. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article evaluates space closure mechanics efficiency in an extraction case where maximum anchorage was a requirement. The Segmented Arch Technique (SAT) was utilized as an anchorage control strategy to obtain maximum anterior retraction and, in consequence, significant facial profile change. A 20-year-10-month old woman needed severe labial and profile changes. The patient had four premolars extracted and SAT with type A mechanics [1] (Marcotte [2] activation protocol) was applied. The results showed significant reduction in labial protrusion and incisal angulation with effective anchorage control. The results were compared to others available in the literature derived from different techniques, where anterior retraction was also accomplished with maximum anchorage [3-7]. In conclusion, the SAT with type A mechanics has been shown to be another treatment option when significant changes in the soft-tissue profile are needed in extraction cases. © 2008. CEO. Published by Elsevier Masson SAS. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)