92 resultados para Reproducibility of results


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two auxiliary methods of diagnosing nasopharyngeal airway obstruction were compared. Cephalometric radiography and nasopharyngeal videoendoscopy were evaluated for efficacy in terms of reproducibility and validity. Thirty orthodontic patients (7 to 12 years of age) seeking otorhinolaryngologic treatment for mouth breathing, or mouth and nose breathing, had nasopharyngeal endoscopy and radiographic examinations performed on the same day. Two otorhinolaryngologists analyzed the results. Nasopharyngeal endoscopy was more reliable in identifying all the obstructive nasopharyngeal processes. Endoscopy obtained kappa index scores of almost perfect agreement for diagnosis of posterior nasal septum deviation, of substantial agreement for anterior nasal septum deviation and lower turbinate hypertrophy, and of moderate agreement for middle turbinate hypertrophy. Lateral cephalometric radiography obtained scores of perfect agreement for imaging hypertrophy of the middle turbinate, of almost perfect agreement for imaging hypertrophy of the posterior portion of the inferior turbinate, and of substantial agreement for imaging hypertrophy of the inferior turbinate. Radiographic diagnoses of hypertrophy of the middle and lower turbinates exhibited high sensitivity and low specificity when compared with diagnoses by nasopharyngeal endoscopy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the cross-cultural adaptation and validation into Brazilian-Portuguese of the parent's version of two health related quality of life instruments. The Childhood Health Assessment Questionnaire (CHAQ) is a disease specific health instrument that measures functional ability in daily living activities in children with juvenile idiopathic arthritis (JIA). The Child Health Questionnaire (CHQ) is a generic health instrument designed to capture the physical and psychosocial well-being of children regardless the underlying disease. The Brazilian CHAQ was revalidated, while the CHQ has been derived from the Portuguese version. A total of 471 subjects were enrolled: 157 patients with JIA (27% systemic onset, 38% polyarticular onset, 9% extended oligoarticular subtype, and 26% persistent oligoarticular subtype) and 314 healthy children. The CHAQ discriminated clinically healthy subjects from JIA patients, with the systemic, polyarticular and extended oligoarticular subtypes having a higher degree of disability, pain, and lower overall well-being scores when compared to their healthy peers. Also the CHQ discriminated clinically healthy subjects from JIA patients, with the systemic onset, polyarticular onset and extended oligoarticular subtypes having a lower physical and psychosocial well-being score when compared to their healthy peers. In conclusion the Brazilian versions of the CHAQ-CHQ are reliable and valid tools for the combined physical and psychosocial assessment of children with JIA. © Copyright Clinical and Experimental Rheumatology 2001.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The trapezius and serratus anterior muscles were studied in four modalities of rowing exercises executed with two grips, middle and closed, in comparison with the four different modalities of frontal-lateral cross, dumbbells exercise. It was used 24 male volunteers, 18 to 25 years old using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. The results showed that TS acted in a higher significant way in all the modalities of rowing than in the supine lateral raise, inclined supine lateral raise and reverse supine lateral raise, dumbbells exercises, and demonstrated no standing frontal-lateral cross, dumbbells. The SI acted more significantly difference among all the execution modalities of rowing and the inclined supine lateral raise, dumbbells exercises than in all the rowing exercises; even though the activity levels do not make us suggest them as an excellent group of exercises for the development of this muscle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Because the lack of textbooks based on electromyographic studies in the area of exercises for physical conditioning, the authors proposed to study the trapezius (upper portion) (TS) and the serratus anterior (lower portion) (SI) muscles during the execution of four different modalities of rowing exercises with middle grip in 24 male volunteers, 18 to 25 years old. For the recordings, it was used a two-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For the movements, a supine bench and a 120 cm-long bar made of low weight wood were used. The results showed that TS acted significantly in upright, sitting and inclined rowing, justifying its inclusion in physical conditioning programmes, while SI, in spite of acting preferentially in upright and sitting rowing, presented activity levels which do not justify its inclusion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Statement of problem. Little data are available regarding the effect of heat-treatments on the dimensional stability of hard chairside reline resins. Purpose. The objective of this in vitro study was to evaluate whether a heat-treatment improves the dimensional stability of the reline resin Duraliner II and to compare the linear dimensional changes of this material with the heat-polymerized acrylic resin Lucitone 550. Material and methods. The materials were mixed according to the manufacturer's instructions and packed into a stainless steel split mold (50.0 mm diameter and 0.5 mm thickness) with reference points (A, B, C, and D). Duraliner II specimens were polymerized for 12 minutes in water at 37°C and bench cooled to room temperature before being removed from the mold. Twelve specimens were made and divided into 2 groups: group 1 specimens (n=6) were left untreated, and group 2 specimens (n=6) were submitted to a heat-treatment in a water bath at 55°C for 10 minutes and then bench cooled to room temperature. The 6 Lucitone specimens (control group) were polymerized in a water bath for 9 hours at 71°C. The specimens were removed after the mold reached the room temperature. A Nikon optical comparator was used to measure the distances between the reference points (AB and CD) on the stainless steel mold (baseline readings) and on the specimens to the nearest 0.001 mm. Measurements were made after processing and after the specimens had been stored in distilled water at 37°C for 8 different periods of time. Data were subjected to analysis of variance with repeated measures, followed by Tukey's multiple comparison test (P<.05). Results. All specimens exhibited shrinkage after processing (control, -0.41%; group 1, -0.26%; and group 2, -0.51%). Group 1 specimens showed greater shrinkage (-1.23%) than the control (-0.23%) and group 2 (-0.81%) specimens after 60 days of storage in water (P<.05). Conclusion. Within the limitations of this study, a significant improvement of the long-term dimensional stability of the Duraliner II reline resin was observed when the specimens were heat-treated. However, the shrinkage remained considerably higher than the denture base resin Lucitone 550. Copyright © 2002 by The Editorial Council of The Journal of Prosthetic Dentistry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The double pulley equipment was tested on ten male volunteers during contraction of the semitendinosus and biceps femoris (caput longum) muscles in the following movements of the lower limbs: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. The myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. The semitendinosus and biceps femoris muscles presented the highest potentials in movements 1; 2; 7, 8 and 9, whereas the potentials in the remaining movements were negligible. The pattern of activity of the semitendinosus and the biceps femoris was similar in exercises 1, 2, 3, 4 and 8. The potentials of the semitendinosus prevailed in movements 5, 6 and 7, and the strongest potentials observed in movement 9 were those of the biceps femoris.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Because the lack of specialized textbooks, the select of basic exercises for physical conditioning programmes is based on empirical knowledge. This fact led the authors to propose the study on electromyographic activity of the trapezius (upper portion) (TS) and the serratus anterior (lower portion) (SI) muscles in rowing exercises with closed grip in three different modalities. The tests were carried out with 24 male volunteers, 18 to 25 years old, by using a two-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For exercises execution, a long bar made of light wood was used. TS acted significantly in the three different modalities, that is, upright, sitting and bent over, while SI acted preferentially in upright and sitting rowing exercises, justifying their inclusion as basic exercises in physical conditioning programmes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Because the lack of specialized textbooks on the select and indication of basic exercises for physical conditioning programmes, an electromyographic study of the trapezius (upper portion) (TS) and the serratus anterior (lower portion) (SI) muscles in rowing exercises with middle and closed grip in three different modalities, upright, sitting and bent over was performed. The tests were carried out with 24 male volunteers, 18 to 25 years old, by using a two-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For exercises execution, a supine bench, a straight board and a 1,20 m-long bar made of light wood were used. The results showed that TS acted preferentially with closed grip sitting and bent over modalities, and presented no difference among the grips for upright rowing. SI acted preferentially with closed grip in all modalities, however, with activity levels that do not justify its indication for physical conditioning programmes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electromyographic activity of the shoulder muscles deltoid - anterior portion (DA) and pectoralis major - clavicular portion (PMC) was tested on 24 male volunteers using a 2 channel TEC A TE4 electromyograph and Hewlett Packard surface electrodes during the execution of four different modalities of frontal-lateral cross, dumbbells exercises. The results showed that all of the tested exercises developed high levels of action potential for both muscles. So, we jusfity the indication of all of them for physical fitness programmes for DA and PMC. Some suggestions to the use of the tested exercises are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The action potential level for shoulder muscles deltoid-anterior portion (DA) and pectoralis major-clavicular portion (PMC) determined by four different modalities of execution of rowing exercises, each one with two different grips, was recorded. These were compared with the action potential level determined for the same muscles by four different modalities of execution of the frontal-lateral cross, dumbbells exercises. Twenty-four male volunteers were examined using a 2 channel TECA TE4 electromyograph and Hewlett Packard surface electrodes. The statistic analysis showed significant (p<0,05) superiority for all the frontal-lateral cross, dumbbells exercises in comparison to all rowing exercises for the PMC, for the DA this generalized supremacy was not observed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Canine mammary tumors are challenging for clinicians and pathologists because of complex histologic classification, low specificity of cytologic diagnosis, and unpredictable biological behavior. In histologic specimens, expression of tumor proliferation marker Ki-67, a nuclear nonhistone protein, has been shown to have prognostic value for canine mammary tumors and to correlate with malignancy and low survival rates. Objective: The objective of this study was to measure the proliferation index of canine mammary tumors by immunochemical detection of Ki-67 in cytologic specimens and to determine its relationship to clinical and pathologic variables and patient outcome. Methods: Spontaneous mammary tumors from 31 female dogs were surgically excised. Imprint specimens for cytologic evaluation were wet-fixed in ethanol; histologic specimens were prepared routinely. Immunostaining was performed with the PH 177 monoclonal antibody against Ki-67; proliferation index was graded from negative to +++. Dogs were followed for 18 months. Multivariate logistic regression analysis was used to determine correlations between immunocytochemical results, tumor and clinical variables, and patient outcome. Results: Ki-67 proliferation indices in cytologic specimens were significantly lower for nonmalignant tumors than for malignant tumors. High index values of Ki-67 were positively correlated with metastasis, death from neoplasia, low disease-free survival rates, and low overall survival rate. With the exception of 4 specimens for which cellularity was insufficient, positive expression of Ki-67 in cytologic specimens correlated with that of histologic specimens. Conclusions: The prognostic value of the Ki-67 index in canine mammary tumors by using wet-fixed cytology imprint specimens was similar to that observed previously for histologic specimens. Immunocytochemical detection of Ki-67 could improve the accuracy and value of cytology by providing safe and rapid information about malignancy and patient outcome. © 2004 American Society for Veterinary Clinical Pathology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the diagnostic agreement of conventional panoramic radiographs and their inverted scanned images in the detection of the mandibular canal and mental foramen. A total of 77 panoramic radiographs obtained from the files of totally edentulous patients were used. Digitization was done by means of a scanner with brightness and contrast adjustment, as well as image inversion. The extension of mandibular canal was divided into anterior, middle, and posterior regions, and the presence of a radiopaque line that characterized the mandibular canal was classified according to a 5-point confidence scale. The mental foramen was classified in 4 types: continuous, separated, diffuse, and unidentified. Both conventional and inverted scanned panoramic radiographs were evaluated by 3 calibrated implantologists at 2 distinct moments with a minimum interval of 10 days between them. Intraexaminer agreement was evaluated by Kappa statistics by point and by 95% confidence interval. Because the intraexaminer level of agreement was low, interexaminer agreements could not be carried out. The results showed a substantial (in 2 situations), moderate (in 16 situations), and fair (in 18 situations) intraexaminer agreement for mandibular canal and a substantial (in 1 situation), fair (in 1 situation), and moderate (in 10 situations) intraeaminer agreement for mental foramen. There were no statistically significant differences in most instances. In conclusion, the diagnostic agreement of conventional and inverted scanned panoramic radiographs for detection of mandibular canal and mental foramen was low.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The accuracy of impressions that transfer the relationship of the implant to the metal framework of the prosthesis continues to be a problem. This study was designed to evaluate the accuracy of the transfer process under variable conditions with regard to implant analog angulations, impression materials, and techniques. Replicas (n = 60) of a metal matrix (control) containing four implants at 90°, 80°, 75°, and 65° in relation to the horizontal surface were obtained by using three impression techniques: T1 - indirect technique with conical copings in closed trays; T2 - direct technique with square copings in open trays; and T3 - square copings splinted with autopolymerizing acrylic resin; and four elastomers: P-polysulfide; I-polyether; A-addition silicone; and Z-condensation silicone. The values of the implant analog annulations were assessed by a profilometer to the nearest 0.017°, then submitted to analysis of variance for comparisons at significance of 5% (P < .05). For implant analog at 90°, the material A associated with T2 and material Z with T3 behaved differently (P < .05) from all groups. At 80°, all materials behaved differently (P < .01) with T1. At 75°, when T1 was associated, materials P and A showed similar behavior, as well as materials I and Z; however, P and A were different from I and Z (P < .01). When T3 was associated, all experimental groups behaved differently among them (P < .01). At 65°, the materials P and Z behaved differently (P < .01) from the control group with T1, T2, and T3; the materials I and A behaved differently from the control group (P < .01) when T1 and T2, respectively, were associated. The more perpendicular the implant analog annulation is in relation to the horizontal surface, the more accurate the impression. The best materials were material I and A and the most satisfactory technique was technique 3.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Methods were developed for the analysis of acetonitrile and its metabolite cyanide in the blood of rats exposed to acetonitrile. Acetonitrile was analyzed by the headspace technique coupled to gas chromatography with detection by flame ionization, and cyanide was analyzed by high-performance liquid chromatography with fluorescence detection (λ ex = 418 nm and λ em = 460 nm) after derivatization of the ion with naphthalene 2,3-dicarboxyaldehyde and taurine. The quantitation limits of the methods for the analysis of acetonitrile and cyanide were 4.875 μg/mL and 0.025 μg/mL, respectively. The coefficients of variation of 10% or less obtained for intra- and interassay precision indicate the precision of these analytical methods and the systematic errors, all less than 5%, indicate that the methods are quite accurate. The methods were applied to an experimental study after the animals received acetonitrile at the doses of 2 mmol/kg or 5 mmol/kg.