17 resultados para Racionamento


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work aims to conduct a study of the economic feasibility of the implementation of variable frequency inverters in pump systems with variable flow rates. The concern with the reduction of energy expenditure in industries raised in 2001 due to the energy crisis that hit Brazil at that time, forcing industries to reduce their electric costs under penalty of fines if this were not done (MOREIRA, 2008). Frequency inverter is an electronic device that allow greater control in the operation of pumping systems and also a reduction in electrical consumption, being a viable solution to achieve a reduction in energy consumption. For the development of this work, approaching important topics in pumping systems was necessary in order to make a correct choice of hydraulic pumping and also other components responsible for the operation of the system , such as electric motors and frequency inverters. In the case study, a theoretical analysis of the behavior of electrical consumption in systems with variable flow rates was performed, comparing when the system is operated via frequency inverters and when the system is operated without such a device. As expected, the result of the implantation of the device was quite satisfactory, and the primary goal of reducing energy expenditure was achieved. Also important to highlight the environmental issue of this work, as all forms of energy production affects nature in some way, achieving a reduction in consumption also contributes indirectly in environmental conservation