81 resultados para RATINGS
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
There is a poor association between the dentist's evaluation of denture quality and patients' satisfaction with their dentures. Possible differences between dental professionals and patients' expectations might help explain differences in outcome evaluations. This study compared scores given by a dentist, a dental technician and patients for their expectations before and their final evaluation after complete dentures treatment. Twenty completely edentulous patients, a prosthodontist and a dental technician provided scores for the expected aesthetic and functional results of their dentures based on a visual analogue scale at baseline. Post-treatment completion ratings were given after adjustments, by dentist and patients. The dental technician provided post-treatment completion ratings after completing the dentures. The patients had higher expectations than the dental technician and the dentist perceived for both aesthetic and function (P < 0.001). The patients also presented higher post-treatment completion ratings than the dental professionals perceived for final aesthetics (P = 0.016, Kendall's W = 0.207). and function (P = 0.002, Kendall's W = 0.303). Only the dentist presented a statistically significant difference between expectations (lower) and final (higher) outcomes for aesthetics (P = 0.017) and function (P = 0.003). There was no correlation between expectations and post-treatment completion ratings according to the patients' age. There was also no correlation between the patients' gender and expectation scores. Patients presented higher expectations regarding their dentures than dental professionals. The dentist believed that dentures would bring fewer benefits than patients did, but his perception of denture benefits post-treatment was significantly higher than his expectations.
Resumo:
Aims: To compare kinematic parameters (ie, amplitude, velocity, cycle frequency) of chewing and pain characteristics in a group of female myofascial temporomandibular disorder (TMD) patients with an age-matched control female group, and to study correlations between psychological variables and kinematic variables of chewing. Methods: Twenty-nine female participants were recruited. All participants were categorized according to the Research Diagnostic Criteria for TMD (RDC/TMD) into control (n = 14, mean age 28.9 years, SD 5.0 years) or TMD (n = 15, mean age 31.3 years, SD 10.7) groups. Jaw movements were recorded during free gum chewing and chewing standardized for timing. Patients completed the Depression, Anxiety, and Stress Scales (DASS-42), the Pain Catastrophizing Scale (PCS), the Fear of Pain Questionnaire-III (FPQ-III), and the Pain Self-Efficacy Questionnaire (PSEQ). Statistical analyses involved evaluation for group differences, and correlations between kinematic variables and psychological questionnaire scores (eg, depression, anxiety, stress) and pain intensity ratings. Results: Velocity and amplitude of standardized (but not free) chewing were significantly greater (P < .05) in the TMD group than the control group. There were significant (P < .05) positive correlations between pain intensity ratings and velocity and amplitude of standardized chewing but not free chewing. There were significant (P < .05) positive correlations between depression and jaw amplitude and stress and jaw velocity for standardized but not free chewing. Conclusion: This exploratory study has provided data suggesting that psychological factors, manifesting in depression and stress, play a role in influencing the association between pain and motor activity. J OROFAC PAIN 2011;25:56-67
Resumo:
P>Considering the importance of patients' satisfaction with complete denture therapy and the influence of psychosocial aspects and expectations regarding satisfaction with their dentures, the present study aimed to test for a correlation between locus of control profiles and expectations before and satisfaction after complete denture therapy. Sixty-four patients rated their expectations for aesthetic and functional results of complete denture therapy on a 10-cm visual analogue scale (VAS), using scores from 0 (worst results) to 10 (best results). A similar questionnaire was used regarding satisfaction after final denture adjustments. Patients also answered a locus of control questionnaire in the initial interview. anova and a chi-squared test were used to test for correlations among ratings, patient gender and locus of control profiles. The significance level adopted was 0 center dot 05. The expectation ratings before treatment were significantly lower than the post-treatment completion ratings, both for aesthetics (P < 0 center dot 001) and function (P = 0 center dot 004). There was no correlation between locus of control profiles and patients' ratings or between gender and VAS scores. No correlation was found between locus of control profiles and scores for expectations before and satisfaction after complete dentures.
Resumo:
The purpose of this in vivo study was to evaluate the clinical performance of a posterior composite resin TRH (Caulk Dentisply) in class I restorations in primary molars. A total of 30 children aged 5 to 8 years old with 49 class I dental lesions in primary molars participated in the study. The cavity preparations involved removal of carious lesion only and the enamel margins were beveled. The results showed after 30 months that, 82% (32/39) of Alfa ratings and 18% (7/39) of Bravo ratings. We concluded that the composite resin TP-H could be used in conservative restorations in primary molars, particularly in the late mixed dentition.
Resumo:
In this paper is proposed and analyzed a digital hysteresis modulation using a FPGA (Field Programmable Gate Array) device and VHDL (Hardware Description Language), applied at a hybrid three-phase rectifier with almost unitary input power factor, composed by parallel SEPIC controlled single-phase rectifiers connected to each leg of a standard 6-pulses uncontrolled diode rectifier. The digital control allows a programmable THD (Total Harmonic Distortion) at the input currents, and it makes possible that the power rating of the switching-mode converters, connected in parallel, can be a small fraction of the total average output power, in order to obtain a compact converter, reduced input current THD and almost unitary input power factor. The proposed digital control, using a FPGA device and VHDL, offers an important flexibility for the associated control technique, in order to obtain a programmable PFC (Power Factor Correction) hybrid three-phase rectifier, in agreement with the international standards (IEC, and IEEE), which impose limits for the THD of the AC (Alternate Current) line input currents. Finally, the proposed control strategy is verified through experimental results from an implemented prototype. ©2008 IEEE.
Resumo:
In this paper is proposed and analyzed a digital hysteresis modulation using a FPGA (Field Programmable Gate Array) device and VHDL (Hardware Description Language), applied at a hybrid three-phase rectifier with almost unitary input power factor, composed by parallel SEPIC controlled single-phase rectifiers connected to each leg of a standard 6-pulses uncontrolled diode rectifier. The digital control allows a programmable THD (Total Harmonic Distortion) at the input currents, and it makes possible that the power rating of the switching-mode converters, connected in parallel, can be a small fraction of the total average output power, in order to obtain a compact converter, reduced input current THD and almost unitary input power factor. Finally, the proposed digital control, using a FPGA device and VHDL, offers an important flexibility for the associated control technique, in order to obtain a programmable PFC (Power Factor Correction) hybrid three-phase rectifier, in agreement with the international standards (IEC, and IEEE), which impose limits for the THD of the AC (Alternate Current) line input currents. The proposed strategy is verified by experiments. © 2008 IEEE.
Resumo:
This paper proposal presents the development and the experimental analysis of a new single-phase hybrid rectifier structure with high power factor (PF) and low harmonic distortion of current (THDI), suitable for application in traction systems of electrical vehicles pulled by electrical motors (trolleybus), which are powered by urban distribution network. This front-end rectifier structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The proposed structure is composed by an ordinary single-phase diode rectifier with parallel connection of a switched converter. It is outlined that the switched converter is capable of composing the input line current waveform assuring high power factor (HPF) and low THDI, as well as ordinary front-end converter. However, the power rating of the switched converter is about 34% of the total output power, assuring robustness and reliability. Therefore, the proposed structure was named single-phase HPF hybrid rectifier. A prototype rated at 15kW was developed and analyzed in laboratory. It was found that the input line current harmonic spectrum is in accordance with the harmonic limits imposed by IEC61000-3-4. The principle of operation, the mathematical analysis, the PWM control strategy, and experimental results of a 15kW prototype are also presented in this paper. © 2009 IEEE.
Resumo:
This paper presents the development and the experimental analysis of a new single-phase hybrid rectifier structure with high power factor (PF) and low harmonic distortion of current (THDI), suitable for application in traction systems of electrical vehicles pulled by electrical motors (trolleybus), which are powered by urban distribution network. This front-end rectifier structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The proposed structure is composed by an ordinary single-phase diode rectifier with parallel connection of a switched converter. It is outlined that the switched converter is capable of composing the input line current waveform assuring high power factor (HPF) and low THDI, as well as ordinary front-end converter. However, the power rating of the switched converter is about 34% of the total output power, assuring robustness and reliability. Therefore, the proposed structure was named single-phase HPF hybrid rectifier. A prototype rated at 15kW was developed and analyzed in laboratory. It was found that the input line current harmonic spectrum is in accordance with the harmonic limits imposed by IEC61000-3-4. The principle of operation, the mathematical analysis, the PWM control strategy, and experimental results are also presented in this paper. © 2009 IEEE.
Resumo:
Background: Neuropsychiatric symptoms (NPS) affect almost all patients with dementia and are a major focus of study and treatment. Accurate assessment of NPS through valid, sensitive and reliable measures is crucial. Although current NPS measures have many strengths, they also have some limitations (e.g. acquisition of data is limited to informants or caregivers as respondents, limited depth of items specific to moderate dementia). Therefore, we developed a revised version of the NPI, known as the NPI-C. The NPI-C includes expanded domains and items, and a clinician-rating methodology. This study evaluated the reliability and convergent validity of the NPI-C at ten international sites (seven languages). Methods: Face validity for 78 new items was obtained through a Delphi panel. A total of 128 dyads (caregivers/patients) from three severity categories of dementia (mild = 58, moderate = 49, severe = 21) were interviewed separately by two trained raters using two rating methods: the original NPI interview and a clinician-rated method. Rater 1 also administered four additional, established measures: the Apathy Evaluation Scale, the Brief Psychiatric Rating Scale, the Cohen-Mansfield Agitation Index, and the Cornell Scale for Depression in Dementia. Intraclass correlations were used to determine inter-rater reliability. Pearson correlations between the four relevant NPI-C domains and their corresponding outside measures were used for convergent validity. Results: Inter-rater reliability was strong for most items. Convergent validity was moderate (apathy and agitation) to strong (hallucinations and delusions; agitation and aberrant vocalization; and depression) for clinician ratings in NPI-C domains. Conclusion: Overall, the NPI-C shows promise as a versatile tool which can accurately measure NPS and which uses a uniform scale system to facilitate data comparisons across studies. Copyright © 2010 International Psychogeriatric Association.
Resumo:
This clinical study assessed the performance of posterior composite resins applied with the Adper™ Single Bond Plus (SB) and Adper ™ Scotchbond SE (SE) adhesive systems and Filtek ™ Supreme Plus composite resin, using modified US Public Health Service criteria. A total of 97 restorations were placed in posterior teeth by two calibrated operators. Application of the materials followed manufacturers' instructions. The restorations were evaluated by two examiners at baseline and after one year. Statistical analyses were conducted using the proportion test at a significance level of 5% (p<0.05). All the restorations evaluated (ie, 100%) received an alpha rating for the criteria of marginal discoloration and marginal integrity at baseline. At one year, for marginal discoloration, 64.6% of SB and 61.2% of SE received an alpha rating. For marginal integrity, 72.9% of SB and 77.6% of SE received an alpha rating. The other restorations received bravo ratings for both criteria. None of the teeth that received the restorative systems presented caries lesions around the restorations. A total of eight teeth presented postoperative sensitivity one week after baseline, five with SB and three with SE; the symptom had disappeared one year later. One year later, composite resin restorations using either adhesive system showed satisfactory clinical performance.
Resumo:
The Brazilian public health system requires competent professionals sensitive to the needs of the population. The Foundation for Advancement of International Medical Education and Research (FAIMER) provides a two-year faculty development programme for health professions educators, aiming to build leadership in education to improve health. A partnership with governmental initiatives and FAIMER was established for meeting these needs. This paper describes the initial process evaluation results of the Brazilian FAIMER Institute Fellowship (FAIMER BR). Methods: Data were analysed for the classes 2007-2010 regarding: application processes; innovation project themes; retrospective post-pre self-ratings of knowledge acquisition; and professional development portfolios. Results: Seventeen of 26 Brazilian states were represented among 98 Fellows, predominantly from public medical schools (75.5%) and schools awarded Ministry of Health grants to align education with public health services (89.8%). One-third (n = 32) of Fellows' innovation projects were related to these grants. Significant increases occurred in all topic subscales on self-report of knowledge acquisition (eff ect sizes, 1.21-2.77). In the follow up questionnaire, 63% of Fellows reported that their projects were incorporated into the curriculum or institutional policies. The majority reported that the programme deepened their knowledge (98%), provided new ideas about medical education (90%) and provided skills for conflict management (63%). One-half of the Fellows reported sustained benefits from the programme listserv and other communications, including breadth of expertise, establishment of research collaboration and receiving emotional support. Conclusion: Contributors to initial programme success included alignment of curriculum with governmental initiatives, curriculum design merging educational technology, leadership and management skills and central role of an innovation educational project responding to local needs.
Resumo:
The possibilities of using the sperm collected from the epididymis have been widely used because the fertilizing capacity sperm preservation and the possibility of using it for wild cats. But in the process of cryopreservation, some studies show a decrease in the quality of the sperm when left under cooling before frozen for some time. This study aimed to assess the quality of the epididymal sperm obtained from domestic cats after cryopreservation using a diluent based on egg yolk and glycerol (Botu-crio®), comparing the morphofunctional characteristics after cooling for 24 hours in a container of semen transport (Botu-tainer®). We use eight cats submitted to elective orchiectomy, aging from eight months, without racial determination, and good nutritional status. These sperm characteristics were: motility, vigor, concentration, membrane integrity and morphology. It has been found, after statistical analysis, that the container of semen was able to maintain sperm viability, even for 24h. We also observed a significant decrease on all parameters after frozen, consequential, probably to thermal stress that occurs in processing. However, the percentage of membrane integrity after thawing shows good employability of the Botu-crio®, which viability is possible to perform in vitro fertilization, requiring higher ratings.
Resumo:
Intercropping corn (Zea mays L.) with palisadegrass [Brachiaria brizantha (Hochst. ex A. Rich) Stapf] can result in high amounts of residue and improve nutrient cycling. Long-season corn hybrids will live longer, competing with palisadegrass, which may reduce both corn and forage biomass yields. This study, conducted in the state of São Paulo, Brazil, had the objective of evaluating nutrient concentration and yield of corn hybrids with different maturity ratings as affected by intercropped palisadegrass as well as forage dry matter production. Te experimental design was randomized blocks with a factorial arrangement of eight treatments consisting of two cropping systems (corn alone and intercropped with palisadegrass) and four corn hybrids (105-, 121-, 132, and 144-d relative maturity). Compared with corn grown alone, intercropping treatments resulted in corn grain yields of 107% (105-d hybrid) to 71.7% (144-d hybrid). In the corn-alone system, the 132- and 144-d corn hybrids provided the highest corn yields (9581 and 9606 kg ha-1, respectively). Corn yield was similar between the single-crop and intercrop systems when using 105-, 121-, and 132-d hybrids. Intercropping with the 144-d hybrid reduced forage production (6619 kg ha-1) and quality of palisadegrass (86 g kg-1 of crude protein) compared with the other hybrids. Te intercropping system with the 132-d hybrid allowed both the highest corn grain (8860 kg ha-1) and palisadegrass (8256 kg ha-1) yields. Therefore, intercropping palisadegrass with the earlier (105-, 121-, and 132-d) corn hybrids is a viable option for crop-livestock integration because it did not affect either corn or palisadegrass yield. © 2013 by the American Society of Agronomy, 5585 Guilford Road, Madison, WI 53711. All rights reserved.
Resumo:
The aims of this study were to assess the validity and the feasibility of the qualitative behavior assessment (QBA) method as indicator of Nellore cattle temperament under field conditions, evaluating its associations with four other traditional methods and weight gain. The temperament and live weight of 2229 Nellore cattle was assessed at approximately 550 days of age. Five measurements of cattle temperament were recorded: flight speed test (FS, in m/s), visual scores of movement in the crush (MOV), crush score (CS), temperament score (TS), and the qualitative behavior assessment method (QBA), by using a list of 12 behavioral based adjectives as descriptors of temperament. Average daily weight gain (ADG) was calculated for each animal. For statistical analysis of QBA data, the Principal Component Analysis was used. A temperament index (TI) was defined for each animal using the scores for the first principal component. Pearson's correlation coefficients were estimated between TI with FS and ADG. A mixed model ANOVA was used to analyze the TI variation as a function of TS, CS, and MOV. The score plot for the first and second principal components was used to classify the cattle in four groups (from very bad to very good temperament). The first principal component explained 49.50% of the variation in the data set, with higher positive loadings for the adjectives 'agitated' and 'active', and higher negative loadings for 'calm' and 'relaxed'. TI was significantly correlated with FS (r=0.49; P<0.01) and ADG (r=-0.10; P<0.01). The means of ADG, FS, and the temperament scores (CS, TS, MOV) differed significantly (P<0.01) among the four groups, from very bad to very good temperament. The QBA method could discriminate different behavioral profiles of Nellore cattle and were in agreement with other traditional methods used as indicators of cattle temperament. Additional studies are needed to assess the inter- and intra-observers reliability and to study its association with physiological parameters. © 2013 Elsevier B.V.