143 resultados para Posicionamento relativo estático


Relevância:

90.00% 90.00%

Publicador:

Resumo:

In the past few years several GPS (Global Position System) positioning techniques have been develope and/or improved with the goal of obtaining high accuracy and productivity in real time. The reference station network concept besides to enabling quality and reliability in positioning for scientific and civil GPS community, allows studies concerning tropospheric refraction modeling in the network region. Moreover, among the network corrections transmission methods available to users, there is the VRS (Virtual Reference Station) concept. In this method, the data of a virtual station are generated near the rover receiver (user). This provides a short baseline and the user has the possibility of using a single frequency receiver to accomplish the relative positioning. In this paper, the methodology applied to generate VRS data, using different tropospheric models is described. Thus, comparative tests were conducted in the four seasons with the NWP/INPE (Numerical Weather Prediction/National Institute for Space Research) and Hopfield tropospheric models. In order to analyse the VRS data quality, it was used the Precise Point Positioning (PPP) method, where satisfactory results were found. Mean differences between PNT/INPE and Hopfield models of 9.75% and 24.2% for the hydrostatic and wet days, respectively were obtained.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A caracterização da variabilidade espacial dos atributos do solo é indispensável para subsidiar práticas agrícolas de maneira sustentável. A utilização da geoestatística para caracterizar a variabilidade espacial desses atributos, como a resistência mecânica do solo à penetração (RP) e a umidade gravimétrica do solo (UG), é, hoje, prática usual na agricultura de precisão. O resultado da análise geoestatística é dependente da densidade amostral e de outros fatores, como o método de georreferencimento utilizado. Desta forma, o presente trabalho teve como objetivo comparar dois métodos de georreferenciamento para a caracterização da variabilidade espacial da RP e da UG, bem como a correlação espacial dessas variáveis. Foi implantada uma malha amostral de 60 pontos, espaçados em 20 m. Para as medições da RP, utilizou-se de penetrógrafo eletrônico e, para a determinação da UG, utilizou-se de trado holandês (profundidade de 0,0-0,1 m). As amostras foram georreferenciadas, utilizando-se do método de Posicionamento por Ponto Simples (PPS), com de (retirar) receptor GPS de navegação, e Posicionamento Relativo Semicinemático, com receptor GPS geodésico L1. Os resultados indicaram que o georreferenciamento realizado pelo PPS não interferiu na caracterização da variabilidade espacial da RP e da UG, assim como na estrutura espacial da relação dos atributos.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Since 2000 the use of the GPS navigation increases considerably. The reason for that was the deactivation of the selective availability in May 2000. However, these receivers do not register the observables, they just estimate and store them and that prevents the post-processing data. Based in this aspect some softwares were developed and are available for free. They allow recording the GPS observables, pseudorange and carrier phase. These programs are able to read in binary files and record information concerning the GPS observables and to convert binary format to a RINEX format. This study presents the GPS Garmin 12 XL evaluation using free programs. Two experiments were carried out in Presidente Prudente-SP region using the relative static survey. The processing was carried out with intervals of 30, 15, 10 and 5 minutes. The results were compared with the coordinates from a geodetic receiver and show that 98.9 % of the points, the values in relation to the planimetric accuracy were better than 0.50 m. The only baseline which the value was larger or equal to 0.50 m is the point M0001 (baseline lesser than 2 km) referred to the first experiment. In terms of precision the values did not exceeded 0.30 m.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Data from reference stations are widely used in GNSS (Global Navigation Satellite System) positioning, and can be used in relative positioning or network-based positioning concept. Positioning accuracy will be directly influenced by errors in signals collected in these stations. In this paper, it is aimed at evaluating these data quality using temporal series of multipath index MP1 and MP2. A statistical study of temporal series with 7 years of daily observations related to 7 stations from RBMC (Rede Brasileira de Monitoramento Contínuo) was accomplished. In order to investigate trends and seasonality a linear regression model, correlograms, and Fourier periodograms were used. We also used a harmonic adjust to identify peaks on temporal series. At last, the possible causes of seasonality found in some stations were discussed. It was also possible to identify peaks in MP values of March and October months (mainly in stations located near geomagnetic equator).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The use of the Global Positioning System technology has brought a real revolution in the surveying and georeferencing techniques, which are the basis for many others relevant studies to the many fields of Geography. In this sense, it was seen a massive growth of the use of GNSS receivers in Brazil from the early 2000s, due the duty of Georreferencing Rural Properties to comply with the 10.267/2001 law. For Georreferencing, it is needed high accuracy receivers, and most of time, it is used two receivers: one static base and one rover. To do the adjustment of the base (in order to correct errors), two ways are utilized: post-processing via the brazilian GNSS network - Rede Brasileira de Monitoramento Contínuo dos Sistemas GNSS (RBMC) or via Precise Point Positioning - Posicionamento por Ponto Preciso, both managed by IBGE. Given the wide range of applications as well as discussions on the accuracy of both methods, this monograph aims to conduct a comparative analysis and prove the effectiveness of both methods considering the INCRA’s Standard for Rural Properties Georreferencing. From the processing of GNSS data collected in Piracicaba, Ituverava, Iperó and São Pedro, it could be seen that the research reached the objectives and shows that both methods are accurate and feasible

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This report shows the resolution of a case study whose aim was promote the aesthetic and functional rehabilitation of upper left hemi-arch over endosseous and needle implant prostheses. To improve the position of the needle implants, we performed the bucco-palatal bending of needles splinting them with composite resin; we removed the screwed implant prosthesis in the regions of the premolars (24 and 25) and molar (26). The mini-abutments of the last two implants were replaced, and in the first premolar and canine, we used cemented abutments due to implant angulation having planned soldering because of implant size and contact with one needle implant that could interfere with intimate contact bone/implant damaging biomechanics. Pick-up impressions were performed with an open tray, using a retractor cord in the needle implants and respective transfer copings. Therefore, models were related on semi-adjustable articulator after a face-bow recording and interocclusal indexes. After working cast fabrication and try-in of infra-structures, these were adjusted and related into the articulator again. Then, after ceramic build-up, adjustments, finishing, and torque, chemically-activated resin cement was applied on units 21 to 24. At the end of the case, we concluded that a good aesthetic and functional rehabilitation depends on thorough knowledge of techniques for each clinical situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A análise de um modelo de erosão é um crítico passo no desenvolvimento de uma ferramenta de predição da erosão aplicável e válida; isso é crucial para avaliar o desempenho dos modelos existentes para assegurar que as estimativas de um modelo condizem com a realidade. O objetivo do presente trabalho foi avaliar modelos para a predição do subfator cobertura e manejo (CiII) relativo à erosão entressulcos. Um experimento fatorial completo foi conduzido com cinco doses de resíduo de milho (0; 0,05; 0,15; 0,40 e 0,80 kg m-2), quatro declives e duas repetições, sob condições de prévio umedecimento para determinar as taxas de erosão entressulcos (Di) e enxurrada (R). Num primeiro experimento, foi avaliada a erodibilidade entressulcos (Ki) e o subfator cobertura e manejo (CiII), em parcelas experimentais de 0,5 x 0,75 m, em solo recentemente preparado. Num segundo experimento, foram avaliados Di, R, Ki e CiII, também em parcelas de 0,5 x 0,75 m, em solo recém- preparado. Os valores de Di, R, Ki e CiII, obtidos no segundo experimento, foram utilizados na avaliação dos modelos testados. Os modelos CiII = e-2,50 CS/100 e CiII = e -2,238 CS/100 apresentaram boas estimativas para o subfator CiII.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Activities that use Global Navigation Satellite System (GNSS) are countless and the most used one is the Global Positioning System (GPS) developed by the United States. In precision agriculture there are demands for static and cinematic positioning with distinct levels of accuracy for different applications; nevertheless cinematic performance data are not available as manufacturers of GPS receivers present only static performance information. For this reason it was developed an instrumented vehicle to test a methodology of performance evaluation of GPS receivers in kinematic conditions, which is representative to agricultural operations. A set of instrumentation was composed and used for collecting data under variable speed and rotation direction. Tests were conducted showing that the methodology allows to measure accuracy and precision, but improvements have to be implemented on the instrumentation equipment for long term tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O clorofilômetro (SPAD-502, Minolta) é um aparelho portátil que permite obtenção do índice relativo de clorofila (IRC) de modo simples, rápido e não destrutivo no próprio campo, o qual se correlaciona com a concentração de N em várias culturas, e que pode tornar mais rápida a correção de deficiência, otimizando a utilização da fertirrigação. Objetivou-se com este trabalho verificar se o IRC pode ser indicativo do estado nutricional em N, podendo auxiliar no ajuste da fertirrigação nitrogenada durante o ciclo do cafeeiro. O experimento foi desenvolvido em Botucatu, SP, em área com cafeeiros do cultivar Catuaí Vermelho, com dois anos, no espaçamento de 2,5 x 0,8 m e irrigado por gotejamento. O delineamento experimental utilizado foi em blocos casualizados, com quatro repetições, aplicando-se um tratamento sem adubação, mas com irrigação, e mais quatro tratamentos utilizando fertirrigação com 33, 66, 100 e 133 % da dose de N recomendada, parcelada semanalmente (52,8; 105,6; 160,0; e 212,7 kg ha-1, respectivamente). O IRC aumentou linearmente com as doses de N, e a produtividade correlacionou-se significativamente com o IRC, do florescimento até a colheita, porém não com a concentração de N foliar. Os IRCs nos cafeeiros com maior produtividade foram de 81,5 a 83,2 (florescimento e início de expansão dos frutos), de 76,2 a 78,3 (expansão dos frutos), de 68,3 a 69,8 (início da granação), de 64,0 a 65,9 (na granação) e de 61,7 a 62,7 unidades SPAD (na maturação). O clorofilômetro pode ser utilizado para definir a probabilidade de resposta ao N no decorrer do ciclo do cafeeiro.