79 resultados para Polyester de Salen
Resumo:
The preparation and electrochemical characterization of a carbon paste electrode modified with the N,N-ethylene-bis(salicyllideneiminato)oxovanadium (IV) complex ([VO(salen)]) as well as its application for ranitidine determination are described. The electrochemical behavior of the modified electrode for the electroreduction of ranitidine was investigated using cyclic voltammetry, and analytical curves were obtained for ranitidine using linear sweep voltammetry (LSV) under optimized conditions. The best voltammetric response was obtained for an electrode composition of 20% (m/m) [VO(salen)] in the paste, 0.10 mol L- 1 of KCl solution (pH 5.5 adjusted with HCl) as supporting electrolyte and scan rate of 25 mV s- 1. A sensitive linear voltammetric response for ranitidine was obtained in the concentration range from 9.9 × 10- 5 to 1.0 × 10- 3 mol L- 1, with a detection limit of 6.6 × 10- 5 mol L- 1 using linear sweep voltammetry. These results demonstrated the viability of this modified electrode as a sensor for determination, quality control and routine analysis of ranitidine in pharmaceutical formulations. © 2013 Published by Elsevier B.V.
Resumo:
High molecular weight semi crystalline thermoplastic poly(ester urethanes), TPEUs, were prepared from a vegetable oil-based diisocyanate, aliphatic diol chain extenders and poly(ethylene adipate) macro diol using one-shot, pre-polymer and multi-stage polyaddition methods. The optimized polymerization reaction achieved ultra-high molecular weight TPEUs (>2 million as determined by GPC) in a short time, indicating a very high HPMDI diol reactivity. TPEUs with very well controlled hard segment (HS) and soft segment (SS) blocks were prepared and characterized with DSC, TGA, tensile analysis, and WAXD in order to reveal structure property relationships. A confinement effect that imparts elastomeric properties to otherwise thermoplastic TPEUs was revealed. The confinement extent was found to vary predictably with structure indicating that one can custom engineer tougher polyurethane elastomers by "tuning" soft segment crystallinity with suitable HS block structure. Generally, the HPMDI-based TPEUs exhibited thermal stability and mechanical properties comparable to entirely petroleum-based TPEUs. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
OBJETIVO: Comparar uma malha comercial de poliéster com o pericárdio bovino preservado em glicerina na reconstituição de defeitos da parede abdominal. MÉTODOS: Foram utilizados 30 ratos, divididos em dois grupos eqüitativos. Efetuou-se uma excisão retangular de 2,5 x 2 cm, incluindo toda a musculatura abdominal e peritônio. No grupo I a parede abdominal foi reparada com malha de poliéster e no grupo II com pericárdio bovino conservado em glicerina. Os animais foram sacrificados aos 15, 60 e 90 dias de pós-operatório, sendo o local cirúrgico avaliado macroscópica e histologicamente. RESULTADOS: Os animais do grupo I apresentaram aderências mais severas e em maior número quando comparados aos do grupo II; porém, sem comprometimento funcional. A análise histológica revelou incorporação dos tecidos aos implantes, com maior resposta fibroblástica nos animais do grupo I. CONCLUSÃO: A malha de poliéster oferece maior resistência estrutural e resposta fibroblástica mais intensa; contudo, promove grande quantidade de aderências às vísceras abdominais, quando comparada ao pericárdio bovino.
Resumo:
Fios de sutura de náilon (0, 3-0 e 4-0), poliéster trançado (0, 3-0 e 4-0) e polipropileno (0, 3-0 e 4-0) de 7 marcas comercializadas no Brasil, foram submetidos a análise de diâmetro, comprimento, resistência do encastoamento, resistência à tração do fio sem nó e resistência à tração do fio com nó, segundo metodologia padronizada pela Associação Brasileira de Normas Técnicas (ABNT). Os resultados obtidos indicam que a maioria dos fios testados encontra-se dentro dos valores preconizados pela ABNT.
Resumo:
This study evaluated: 1) the effect of different ceramics on light attenuation that could affect microhardness, measured as the Knoop Hardness Number (KHN), of a resin cement immediately and 24 hours after polymerization and 2) the effect of different activation modes (direct light-activation, light activation through ceramics and chemical activation) on the KHN of a resin cement.Resin cement Rely X ARC (3M ESPE) specimens 5.0 mm in diameter and 1.0 nun thick were made in a Teflon mold covered with a polyester film. The cement was directly light activated for 40 seconds with an XL 2500 curing unit (3M ESPE) with 650 mW/cm(2), light activated through ceramic discs of Duceram Plus (DeguDent), Cergogold (DeguDent), IPS Empress (Ivoclar), IPS Empress 2 (Ivoclar), Procera. (NobelBiocare), In Ceram Alumina (Vita) and Cercon (DeguDent), having a 1.2 mm thickness or chemically activated without light application. The resin cement specimens were flattened, and KHN was obtained using an HMV 2 microhardness tester (Shimadzu) with a load of 50 g applied for 15 seconds 100 pin from the irradiated surface immediately and after storage at 37 degrees C for 24 hours. Ten measurements were made for each specimen, with three specimens for each group at each time. The data were submitted to ANOVA and Tukey's test (p=0.05). The KHN of the resin cement was not only affected by the mode of activation, but also by the post-activation testing time. The mean KHN of the resin cement for chemical activation and through all ceramics showed statistically significant lower values compared to direct activation immediately and at 24 hours. The KHN for 24 hours post-activation was always superior to the immediate post-activation test except with direct activation. The most opaque ceramics resulted in the lowest KHN values.
Resumo:
Nickel nanoparticles into silica-carbon matrix composites were prepared by using the polymeric precursor method. The effects of the polyester type and the time of pyrolysis on the mesoporosity and nickel particle dispersion into non-aqueous amorphous silica-carbon matrix were investigated by thermogravimetric analysis, adsorption/desorption isotherms and TEM. A well-dispersed metallic phase could be only obtained by using ethylene glycol. Weightier polyesters affected the pyrolysis process due to a combination of more amounts of carbonaceous residues and delaying of pyrolysis process. The post-pyrolyzed composites were successfully cleaned at 200 degrees C for I h in oxygen atmosphere leading to an increase in the surface area and without the occurrence of carbon combustion or nickel nanoparticles oxidation. The matrix composites presented predominantly mesoporous with pore size well defined in 38 angstrom, mainly when tetraethylene glycol was used as polymerizing agent. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
The aim of this paper is to investigate the influence of physical and chemical factors on transport and use of substrate for Atta sexdens rubropilosa workers. Three types of rectangular fragments were used to study the physical influence factors: filter paper with paraffin, filter paper without paraffin and polyester film. To study the chemical factors, some fragments were impregnated with organic extract of orange albedo, others were soaked with soybean oil and for the remaining ones nothing was applied. The following parameters were evaluated: (i) attractiveness of substrate for transport and number of loading workers per treatment; (ii) foraged material incorporation; (iii) rejection by numbers of fragments deposited in the garbage or beside the fungus garden. All the polyester film fragments carried out to the fungus garden were subsequently rejected. We verified that chemical factors of the substrate were more quickly detected by the workers, whereas physical factors were used as a criterion in the decision-making to reject or accept the substrate collected.
Resumo:
O objetivo desse trabalho foi avaliar a influência da intensidade da luz e cor de uma resina composta no grau de dureza Knoop. Corpos-de-prova foram confeccionados utilizando-se matrizes de poliéster envoltas por um anel de cobre, contendo uma cavidade padronizada de 6 mm de diâmetro por 2 mm de espessura. Estas cavidades foram preenchidas com resina composta selecionada, Fill Magic - Vigodent, com as cores A3, B3, C3, D3 e I, fotopolimerizadas através de um fotopolimerizador Elipar, calibrado para produzir 3 intensidades de luz diferentes: 450 mW/cm², 800 mW/cm² e uma intensidade de luz crescente de 100 a 800 mW/cm². Foram confeccionados 90 corpos-de-prova em que o tempo de exposição da resina à luz halógena foi de 40 s. As amostras foram armazenadas em tubos de ensaio com água destilada a 37 ± 1ºC. Após este período, foram realizados os testes de dureza Knoop na região de superfície e fundo. Os resultados mostraram que houve diferença estatística em relação a intensidade de luz, entretanto em relação a cor, não houve diferença estatística. Os autores concluíram que a cor do compósito não influencia a dureza Knoop e que a intensidade progressiva promoveu os melhores resultados de dureza Knoop.
Comparação entre dois fios de sutura não absorvíveis na anastomose traqueal término-terminal em cães
Resumo:
Doze cães sem raça definida, com idade variando entre 1 e 6 anos e peso de 6 a 20kg, foram submetidos a ressecção traqueal e anastomose término-terminal, na qual foram testados os fios poliéster trançado não capilar e náilon monofilamento. Seis animais, cada três com um mesmo tipo de fio de sutura, sofreram a excisão equivalente a três anéis traqueais. Com 15 dias foi executada uma nova intervenção onde se ressecou o equivalente a mais seis anéis, perfazendo um total de nove. Ao final de outros 15 dias foram sacrificados. Os outros seis animais, cada três com um mesmo tipo de fio, foram submetidos à excisão equivalente a três anéis traqueais e mantidos por 43 dias. As traquéias foram avaliadas por exames clínicos, radiográficos, macroscópicos e histopatológicos. O fio de náilon monofilamento apresentou menos reação tecidual do que o poliéster trançado não capilar, promoveu uma anastomose segura e com menor chance de formação de granuloma.
Resumo:
A ruptura do ligamento cruzado cranial é uma das principais doenças ortopédicas que afetam os cães. Muitas técnicas cirúrgicas foram descritas no intuito de aliviar a dor, restaurar a estabilidade biomecânica do joelho e prevenir a progressão da osteoartrite. Fáscia lata, fio de poliéster trançado e fio de poliamida foram empregados na estabilização do joelho após excisão do ligamento cruzado cranial em cães, os quais foram submetidos à avaliação radiográfica e macroscópica da articulação. Neste estudo, foram utilizados 18 cães com massa corporal superior a 15Kg (peso médio - 19,67kg), separados em 3 grupos eqüitativos correspondentes a cada técnica, avaliados durante 30 e 60 dias. Ao exame radiográfico, independentemente de grupo, os cães apresentaram evidência de efusão articular moderada a severa, distensão da cápsula articular e, na maioria dos casos, ausência de sinais de doença articular degenerativa. Ao exame macroscópico da articulação do joelho observou-se espessamento da cápsula articular e tecidos moles periarticulares, erosão da cartilagem articular dos côndilos femorais em todos os grupos e afrouxamento dos fios nos cães submetidos às técnicas de estabilização extra-articular com fio de poliéster trançado e fio de poliamida.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Statement of the Problem: the ceramic composition and surface microstructure of all-ceramic restorations are important components of an effective bonding substrate. Hydrofluoric acid and sandblasting are well-known procedures for surface treatment; however, surface treatment for high alumina-containing and lithium disilicate ceramics have not been fully investigated.Purpose: This in vitro study evaluated the tensile bond strength of resin cement to two types of ceramic systems with different surface treatments.Methods and Materials: Thirty specimens of each ceramic system were made according to the manufacturer's instructions and embedded in polyester resin. Specimens of In-Ceram Alumina [1] and IPS Empress 2 [E] were distributed to three groups with differing surface treatments (n=10): sandblasting with 50 jam aluminum oxide (APA); sandblasting with 110 pm aluminum oxide modified with silica particles (ROCATEC System-RS); a combination of sandblasting with APA and 10% hydrofluoric acid etching (HA) for two minutes on In-Ceram and for 20 seconds for IPS Empress 2. After the respective surface treatments, all the specimens were silanated, and Rely-X resin cement was injected onto the ceramic surface and light polymerized. The specimens were stored in distilled water at 37 degrees C for 24 hours and thermally cycled 1,100 times (5 degrees C/55 degrees C). The tensile bond strength test was performed in a universal testing machine at a 0.5 mm/minute crosshead speed.Results: the mean bond strength values (AWa) for IPS Empress 2 were 12.01 +/- 5.93 (EAPA), 10.34 +/- 1.77 (ERS) and 14.49 +/- 3.04 (EHA). The mean bond strength values for In-Ceram Alumina were 9.87 +/- 2.40 JAPA) and 20.40 +/- 6.27 (IRS). All In-Ceram specimens treated with 10% hydrofluoric acid failed during thermal cycling.Conclusion: the Rocatec system was the most effective surface treatment for In-Ceram Alumina ceramics; whereas, the combination of aluminum oxide sandblasting and hydrofluoric acid etching for 20 seconds worked more effectively for Empress 2 ceramics.