173 resultados para Pessoa em potência
Resumo:
The aim of this study was to access the P-t(Lim) model in swimming, applying the load control available in full tethered swim condition. Its physiological meaning for the determination of boundary of heavy/severe domains was assessed from the relationships with critical velocity (CV), critical power (CP) and maximal lactate steady state (MLSS). The velocity at MLSS (v(MLSS) = 1.17 +/- 0.11 m/s) and CV (1.19 +/- 0.12 m/s) were significantly different. Similarly, the power at MLSS (p(MFEL) = 89.2 +/- 15.1 W) and CP (99.4 +/- 22.9 W) were significantly different. There was no difference between lactate concentration at vMLSS (3.54 +/- 0.9 mM) and p(MLSS) (3.76 +/- 0.6 mM). Significant Pearson's coefficients (r > 0.70) were observed among v(MLSS) and P-MLSS with their respective values on time-limited model. Thus, the tethered-crawl condition seems to be valid to determine the boundary of heavy/severe domains, and to access the aerobic capacity of swimmers.
Resumo:
INTRODUÇÃO: O Running Anaerobic Sprint Test (RAST) tem sido considerado um teste válido para avaliação anaeróbia. Entretanto, como a superfície e o calçado podem afetar alguns parâmetros mensurados durante o exercício, isso pode modificar os parâmetros do RAST. OBJETIVO: Comparar as variáveis do RAST mensuradas utilizando chuteiras na grama (RAST CG) e tênis na pista (RAST TP). MÉTODOS: Oito jogadores de futebol (da categoria sub-17) participaram do estudo. Os participantes realizaram dois RAST (intervalo > 24 h). O RAST consistiu em seis corridas máximas de 35m com 10s de intervalo passivo entre cada corrida. O tempo de cada esforço foi registrado para determinação da potência pico (PP), potência média (PM) e índice de fadiga (IF). Após o sexto esforço, amostras sanguíneas foram coletadas para determinação da lactacidemia ([Lac]). RESULTADOS: Durante o RAST TP, a PP (763,1 ± 87,2 W) e PM (621,6 ± 68,1 W) foram significativamente superiores às PP e PM mensuradas em RAST CG (PP = 667,3 ± 67,0 W e PM = 555,9 ± 74,7 W), enquanto que as [Lac] observadas em RAST TP (7,3 ± 1,8 mmol.L-1) foram significativamente inferiores às mensuradas em RAST CG (9,9 ± 3,2 mmol.L-1). No entanto, o IF não foi significativamente diferente (RAST TP = 32,5 ± 8,3%; RAST CG = 34,1 ± 6,6%). Significativas correlações foram observadas entre as PM (r = 0,90) e as [Lac] (r = 0,72). CONCLUSÃO: Podemos concluir que as variáveis do RAST são influenciadas pela superfície e calçado utilizados, com valores superiores observados em RAST TP.
Resumo:
Este artigo propõe-se a estudar a evolução da proteção internacional dos direitos humanos da pessoa idosa e a posição do Brasil nas discussões sub-regionais, regionais e multilaterais que ocorrem na atualidade, considerando O presente contexto mundial de envelhecimento da população e os novos desafios que essa realidade implica.
Resumo:
A Política Nacional de Saúde da Pessoa Idosa aponta a importância de: divulgação dos direitos da pessoa idosa; promoção do envelhecimento ativo e saudável; formação permanente dos profissionais de saúde e apoio ao desenvolvimento de estudos e pesquisas. São relatados resultados parciais do desenvolvimento de uma experiência de extensão universitária realizada em parceria e com a colaboração da rede de atenção básica. Dentre as atividades realizadas, objetivou-se desenvolver um processo grupal de promoção à saúde com pessoas idosas, tendo em vista o envelhecimento ativo e a qualidade de vida dessa população. Observou-se que as atividades em grupo consistiram em um espaço privilegiado para a constituição de redes de apoio, estabelecimento e ampliação de vínculos afetivos; reflexão e conscientização das determinações do processo saúde-doença; organização e mobilização para o efetivo controle social; além de ser um espaço de ensino-aprendizagem, orientação, intervenção e educação em saúde.
Resumo:
O objetivo do estudo foi avaliar a deposição de óxido de alumínio no campo operatório do cirurgião-dentista durante a utilização do sistema de abrasão a ar em consultório odontológico, bem como a efetividade da sucção de alta potência na captação desse pó. Por meio de um dispositivo para a coleta das partículas nos locais correspondentes às posições e distâncias de trabalho do profissional, dentes artificiais foram abrasionados. O sistema de sucção empregado para aspiração das partículas foi o de alta potência com sugador de saliva convencional e sugador com abertura ampliada por funil. A mensuração das partículas foi determinada pela quantidade em massa de óxido de alumínio depositada em placas de Petri. Os resultados obtidos por meio de estatística descritiva gráfica revelaram que a maior quantidade de pó se encontrava a 20 cm do operador e na posição de trabalho 9h, quando foi utilizado o sugador de saliva convencional. Uma vez comprovado que a sucção não é totalmente eficiente na aspiração do pó de óxido de alumínio, reforça-se a importância da proteção individual apropriada para o emprego seguro do sistema de abrasão a ar para pacientes e, principalmente, para os profissionais que trabalham com este tipo de tecnologia.
Resumo:
The objective of this study was to analyze the relationship of maximal aerobic power and the muscular strength (maximal isotonic strength and vertical jump explosive power) with the running economy (RE) in endurance athletes. Twenty-six male runners (27.9 ± 6.4 years; 62.7 ± 4.3 kg; 168.6 ± 6.1 cm; 6.6 ± 3.1% of body fat) performed in different days the following tests: a) incremental test to determine the maximal oxygen uptake (V̇O2max) and the intensity corresponding to the V̇O2max (IV̇O2max); b) constant-velocity treadmill run to determine RE; c) 1-RM test in the leg press and; d) maximal vertical jump test (VJ). V̇O2max (63.8 ± 8.3 ml/kg/min) was significantly correlated (r = 0.63; p < 0.05) with RE (48.0 ± 6.6 ml/kg/min). However, the IV̇O2max (18.7 ± 1.1 km/h), the maximal isotonic strength (230.3 ± 41.2 kg) and the VJ (30.8 ± 3.8 cm) were not significantly correlated with RE. One concludes that the maximal aerobic power can explain in part the inter-individual RE variability in endurance athletes. However, maximal isotonic strength and explosive strength seem not to be associated with RE values observed in this group of athletes.
Resumo:
The perceived exertion has been a target of several investigations, many times with association with objective physiological indicators in exercise. Recently, the identification of the perceived exertion threshold (PET) was proposed in the water running, which presented no difference in relation to the critical velocity. Theoretically, both parameters would be indicators of the maximum steady state of variables such as V̇O2 and blood lactate. The objective of this work was to verify the coincidence between PET, critical power (PCrit) and an indicator of maximum V̇O2 steady state (PCrit') in cycle ergometer. Eight male participants were submitted to progressive effort test in order to determine V̇O2peak (46.7 ± 8.5 ml/kg/min) and to four rectangular tests until exhaustion for the estimation of the critical power model parameters, PET and PCrit'. The hyperbolic relation between mechanical power and time spent for the V̇O2peak to be reached in each test was used for the PCrit' estimation, considered as the asymptote in the power axis, and the portion of the anaerobic work capacity (CTAnaer) depleted up to the establishment of the V̇O2peak (CTAnaer'). In order to identify PET, the straight lines angular coefficients of the perceived exertion in time (ordinate) and the powers used (abscissa) were adjusted to a linear function that provided a point in the power axis in which the perceived exertion would be kept indefinitely stable. The parameters PCrit and CTAnaer were estimated by means of the power-time non-linear equation. In order to compare the estimations of PET, PCrit and PCrit', the analysis of variance ANOVA for repeated measurements was employed, and the associations were established through the Pearson correlation. CTAnaer and CTAnaer' were compared through the t test. PET (180 W ± 61 W), PCrit (174 W ± 43 W) and PCrit' (176 W ± 48 W) were not significantly different and the correlations were of 0.92-0.98. CTAnaer' (14,080 ± 5,219 J) was lower than CTAnaer (22,093 ± 9,042 J). One concludes that the PET predicts the intensity of PCrit and PCrit' with accuracy.
Resumo:
Objective: To evaluate the biosecurity measures adopted in dental prosthesis laboratories of the city of João Pessoa, PB, Brazil with respect to prosthetic works sent by dentists. Method: Twenty-five dental prosthesis technicians (DPT) of the city of João Pessoa, PB, filled out a questionnaire referring to their knowledge of the biosecurity principles, disinfection of impressions and other prosthetic items, and the use of individual protection equipment (IPE). Results: Although 92% of the interviewees believed in the possible occurrence of cross-infection between dental prosthesis laboratories and dental offices, 64% declared that the prosthetic works received in their laboratories do not undergo any disinfection procedure. It was also observed that, for disinfection of impressions and stone casts, the chemical substances are not used as recommended by the manufacturers or are innocuous to microorganisms. Regarding the use of IPE, 60% of the DPT used mask, but only 4% used gowns. With respect to the measures taken regarding the impressions received from dental offices, 56% of the interviewees only wash them in running tap water, and 56% of the stone casts that arrive at the laboratory are not disinfected in any way. Conclusion: There is a need for more motivation and instructions to DPT regarding the prevention of cross-contamination during sending and receiving of prosthetic works between dental prosthesis laboratories and dental offices because the DPT evaluated in this study were found negligent with respect to disinfection procedures.
Resumo:
This paper proposes and describes a high power factor AC-AC converter for naval applications using Permanent Magnet Generator (PMG). The three-phase output voltages of the PMG vary from 260 Vrms (220 Hz) to 380 Vrms (360 Hz), depending on load conditions. The proposed converter consists of a Y-/ΔY power transformer, which provides electrical isolation between the PMG and remaining stages, and a twelve-pulse uncontrolled rectifier stage directly connected to a single-phase inverter stage, without the use of an intermediary DC-DC topology. This proposal results in more simplicity for the overall circuitry, assuring robustness, reliability and reduced costs. Furthermore, the multipulse rectifier stage is capable to provide high power factor and low total harmonic distortion for the input currents of the converter. The single-phase inverter stage was designed to operate with wide range of DC bus voltage, maintaining 120 Vrms, 60 Hz output. The control philosophy, implemented in a digital signal processor (DSP) which also contains protection routines, alows series connections between two identical converters, achieving 240 Vrms, 60 Hz total output voltage. Measured total harmonic distortion for the AC output voltage is lower than 2% and the input power factor is 0.93 at 3.6kW nominal load. © 2010 IEEE.
Resumo:
In this paper the point estimation method is applied to solve the probabilistic power flow problem for unbalanced three-phase distribution systems. Through the implementation of this method the probability distribution functions of voltages (magnitude and angle) as well as the active and reactive power flows in the branches of the distribution system are determined. Two different approaches of the point estimation method are presented (2m and 2m+1 point schemes). In order to test the proposed methodology, the IEEE 34 and 123 bus test systems are used. The results obtained with both schemes are compared with the ones obtained by a Monte Carlo Simulation (MCS).
Resumo:
The aim was to identify the perception of Oral Health Planning (OHP) of basic care (BC) dental surgeons (DSs) in João Pessoa, Paraíba State, Brazil. Seventeen BC DSs from João Pessoa were interviewed. A qualitative analysis was performed using the Discourse of the Collective Subject (DCS) methodology. DCS obtained: Impact - My work is effective when the user's need remains at the BC. Social Control - The population participates in the organization of promotional activities, but I think it doesn't have enough maturity to opine on OHP. OHP Basis and Organization - The OHP has a diverse organization and is based on user needs. It can be concluded that the knowledge of the DSs on OHP is varied. There is limited understanding about problem-solving. Social control is considered incipient and weak. It is understood that the organization of the local OHP assumes a diverse character and should be based on user demands.
Resumo:
The maximal oxygen uptake (VO2max) is the maximal quantity of energy that can be produced by the aerobic metabolism in certain time unity. It can be determined direct or indirectly by predictive equations. The objective of this study was to make a specific predictive equation to determine the VO 2max from boys aged 10-16 years-old. Forty-two boys underwent a treadmill running ergospirometric test, with the initial velocity set at 9 km/h, until voluntary exhaustion. By the multiple linear regression was possible to develop the following equation for the indirect determination of the VO 2max: VO2max (ml/min) = -1574.06 + (141.38 x Vpeak) + (48.34 * Body mass), with standard error of estimate = 191.5 ml/min (4.10 ml/kg/min) and coefficient of determination = 0.934. We suggest that this formula is appropriate to predict VO2max for this population.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)