92 resultados para POLY(PROPYLENE GLYCOL)
Resumo:
In this work, siloxane-poly(propylene oxide) discs (PPO disc) prepared using the sol-gel process were used as solid phase in enzyme-linked immunosorbent assays (ELISA) for the detection of anti-hepatitis C virus (HCV) antibodies. The HCV RNA from serum (genotype 1b) was submitted to the RT-PCR technique and subsequent amplification of the HCV core 408 pb. This fragment was cloned into expression vector pET42a and expressed in Escherichia coli as recombinant protein with glutathione S-transferase (GST). Cell cultures were grown and induced having a final concentration of 0.4 x 10(-3) mol L-1 of IPTG. After induction, the cells were harvested and the soluble fraction was analyzed using polyacrilamide gel 15% showing a band with an approximate molecular weight of 44 kDa, the expected size for this GST-fused recombinant protein. The recombinant protein was purified and continued by immunological detection using HCV-positive serum and showed no cross-reactivity with positive samples for other infectious diseases. An ELISA was established using 1.25 ng of recombinant protein per PPO disc, a dilution of 1: 10,000 and 1:40 for a peroxidase conjugate and serum, respectively, and solutions of hydrogen peroxide and 3,3',5,5'-tetra-methylbenzidine in a ratio of 1: 1. The proposed methodology was compared with the ELISA conventional polystyrene-plate procedure and the performance of the PPO discs as a matrix for immunodetection gave an easy synthesis, good performance and reproducibility for commercial application. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
The rheological behavior of poly(ethylene glycol) of 1500 g·mol -1(PEG1500) aqueous solutions with various polymer concentrations (w = 0.05, 0.10, 0.15, 0.20 and 0.25) was studied at different temperatures (T = 283.15, 288.15, 293.15, 298.15 and 303.15) K. The analyses were carried out considering shear rates ranging from (20 to 350) s-1, using a cone-and-plate rheometer under controlled stress and temperature. Classical rheological models (Newton, Bingham, Power Law, Casson, and Herschel-Bulkley) were tested. The Power Law model was shown suitable to mathematically represent the rheological behavior of these solutions. Well-adjusted empirical models were derived for consistency index variations in function of temperature (Arrhenius-type model; R2 > 0.96), polymer concentration (exponential model; R2 > 0.99) or the combination of both (R 2 > 0.99). Additionally, linear models were used to represent the variations of behavior index in the functions of temperature (R2 > 0.83) and concentration (R2 > 0.87). © 2013 American Chemical Society.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The objective was to identify a fat-to-protein ratio (FPR) cut-off to diagnose subclinical ketosis (SCK) and to evaluate the effect of propylene glycol (PPG) treatment of cows with high FPR. The optimized cut-off was > 1.42; sensitivity (Se) = 92%; specificity (Sp) = 65%. A cut-off > 1.5 was selected for the PPG trial for balanced Se-Sp. Fat-to-protein ratio cut-offs > 1.25, 1.35, 1.50, 1.60, and 1.70 resulted in Se-Sp of 100% to 49%, 96% to 59%, 75% to 78%, 33% to 90%, and 8% to 96%, respectively. The proportions of cows with FPR > 1.25, 1.35, 1.42, 1.50, 1.60, and 1.70 were 60%, 50%, 44%, 30%, 14%, and 6%, respectively. Incidences of clinical ketosis and milk yield were similar between cows that received 400 mL of PPG (n = 34) and control cows (n = 38). Prevalence of SCK at enrollment was 29.2%; therefore, FPR > 1.5 is not indicated for treatment. Lower cut-offs should be used for screening.
Small-angle X-ray scattering study of sol-gel-derived siloxane-PEG and siloxane-PPG hybrid materials
Resumo:
Hybrid organic-inorganic two-phase nanocomposites of siloxane-poly(ethylene glycol) (SiO3/2-PEG) and siloxane-poly(propylene glycol) (SiO3/2-PPG) have been obtained by the sol-gel process. In these composites, nanometric siloxane heterogeneities are embedded in a polymeric matrix with covalent bonds in the interfaces. The structure of these materials was investigated in samples with different molecular weights of the polymer using the smalt-angle X-ray scattering (SAXS) technique. The SAXS spectra exhibit a well-defined peak that was attributed to the existence of a strong spatial correlation of siloxane clusters. LiClO4-doped siloxane-PEG and siloxane-PPG hybrids, which exhibit good ionic conduction properties, have also been studied as a function of the lithium concentration [O]/[Li], O being the oxygens of ether type. SAXS results allowed us to establish a structural model for these materials for different basic compositions and a varying [Li] content. The conclusion is consistent with that deduced from ionic conductivity measurements that exhibit a maximum for [O]/[Li] =15.
Resumo:
This study was undertaken to compare cryotolerance, in terms of viability and resumption of meiosis after warming and culture (24 and 48 h), of ex situ (isolated) and in situ (enclosed in the ovarian tissue) feline cumulusoocyte complexes (COCs) vitrified with DAP 213 (2 M DMSO, 1 M acetamide, 3 M propylene glycol) in cryotubes or Cryotop method. Ovaries were harvested from 49 pubertal queens. of each pair of ovaries, one was dissected to release COCs randomly divided into three groups: fresh COCs (control), ex situ COCs vitrified with DAP 213 and Cryotop. The cortex of the other ovary was sectioned into small fragments (approximately 1.5 mm3) and randomly assigned to be vitrified by DAP 213 or Cryotop. After warming, ex situ and in situ (retrieved form vitrified ovarian tissue) COCs were matured in vitro. Viability of oocytes was highly preserved after warming and culture in all treatments. Proportions of oocytes surrounded by complete layers of viable cumulus cells were remarkably decreased (p < 0.00001) in both vitrification procedures compared to fresh oocytes. Resumption of meiosis occurred in all treatments. After 24 h of culture, results were similar in ex situ and in situ vitrified oocytes regardless of the vitrification protocol used (range 29-40%), albeit lower (p < 0.05) than those of fresh oocytes (65.8%). After 48 h of culture, ex situ oocytes vitrified with Cryotop achieved the rates of meiosis resumption similar to fresh oocytes (53.8% vs 67.5%; p > 0.05) and ex situ and in situ oocytes vitrified with DAP 213 showed similar rates of resumption of meiosis. These findings demonstrated that DAP 213 and Cryotop preserve the viability of ex situ and in situ oocytes, but cumulus cells are highly susceptible to vitrification. However, the capability to resume meiosis evidences that feline immature oocytes vitrified as isolated or enclosed in the ovarian cortex have comparable cryotolerance.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pyrazinamide was condensed with the poly(ethylene glycol)-poly(aspartic acid) copolymer (PEG-PASP), a micelle-forming derivative was obtained that was characterized in terms of its critical micelle concentration (CMC) and micelle diameter. The CMC was found by observing the solubility of Sudan III in Poly(ethylene glycol)-poly(pyrazinamidomethyl aspartate) copolymer (PEG-PASP-PZA) solutions. The mean diameter of PEG-PASP-PZA micelles, obtained by analyzing the dynamic light-scattering data, was 78.2 nm. The PEG-PASP-PZA derivative, when assayed for anti-Mycobacterium activity, exhibited stronger activity than the simple drug.
Resumo:
Recent advances have accelerated the development of biosensors for the analysis of specific gene sequences. In this kind of biosensor, a DNA probe is immobilized on a transducer and the hybridization with the target DNA is monitored by suitable methodology. In the present work, the streptavidin (STA) was encapsulated in thin films siloxane-poly(propylene oxide) hybrids prepared by sol-gel method and deposited on the graphite electrode surface by dip-coating process. Biotinylated 18-mer probes were immobilized through STA and a novel amperometric DNA biosensor for the detection and genotyping of the hepatitis C virus (genotypes 1, 2A/C, 2B and 3) is described. The HCV RNA from serum was submitted to reverse transcriptase-linked polymerase chain reaction (RT-PCR) and biotin-labeled cDNA was obtained. Thus, the cDNA was hybridized to the target-specific oligonucleotide probe immobilized on the graphite electrode surface and following the avidin-peroxidase conjugate was added. The enzymatic response was investigated by constant potential amperometry at -0.45 V versus Ag/AgCl using H2O2 and KI solutions. HCV RNA negative and positive controls and positive samples of sera patients were analyzed and the results were compared to commercial kit. The proposed methodology appeared to be suitable and convenient tool for streptavidin immobilization and diagnose of HCV disease. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Flexible, transparent, and insoluble urea-cross-linked polyether-siloxane hybrids presenting a tunable drug delivery pattern were prepared using the sol-gel method from PEO (poly(ethylene oxide)) and PPO (poly(propylene oxide)) functionalized at both chain ends with triethoxysilane. Different polyether chain lengths were used to control the urea/siloxane (named ureasil) node density, flexibility, and swellability of the hybrid network. We herein demonstrate that the drug release from swellable hydrophilic ureasil-PEO hybrids can be sustained for some days, whereas that from the unswellable ureasil-PPO hybrids can be sustained for some weeks. This outstanding feature conjugated with the biomedically safe formulation of the ureasil cross-linked polyether-siloxane hybrid widens their scope of application to include the domain of soft and implantable drug delivery devices.
Resumo:
Introduction: The endodontic regenerative procedure (ERP), which is an alternative to calcium hydroxide induced apexification, involves the use of a triple antibiotic paste (TAP) as a dressing material. The aim of this study was to evaluate the response of rat subcutaneous tissue to implanted polyethylene tubes that were filled with TAP or calcium hydroxide. Methods: Thirty rats received 2 individual implants of polyethylene tubes filled with TAP or calcium hydroxide paste (CHP) and another empty tube as a control. Thirty additional rats received 2 individual implants consisting of polyethylene tubes filled with dressing material carriers (macrogol and propylene glycol) and a sham procedure. After 7, 15, 30, 60, and 90 days, 12 animals were euthanized, and the tubes and surrounding tissue were removed and processed for histology by using glycol methacrylate and stained with hematoxylin and eosin. The histological score ranged from 0 to 3 depending on the content of inflammatory cells; the fibrous capsule was considered thin or thick, and necrosis and calcification were recorded as present or absent. The results were analyzed using the Kruskal-Wallis test. Results: Both dressing materials induced moderate reactions at 7 and 15 days. These reactions were similar to the control (P>.05) and reduced in intensity (to mild) from day 30 onward (P>.05). The carriers did not interfere with the reaction of the dressing materials. Conclusions: TAP and CHP were biocompatible over the different experimental periods examined. (J Endod 2012;38:91-94)
Evaluation of pH and Calcium Ion Release of Calcium Hydroxide Pastes Containing Different Substances
Resumo:
Introduction: The objective of this study was to evaluate the pH and calcium ion release of calcium hydroxide pastes associated with different substances. Methods: Forty acrylic teeth with simulated root canals were divided into 4 groups according to the substance associated to the calcium hydroxide paste: chlorhexidine (CHX) in 2 formulations (1% solution and 2% gel), Casearia sylvestris Sw extract, and propylene glycol (control). The teeth with pastes and sealed coronal accesses were immersed in 10 mL deionized water. After 10 minutes, 24 hours, 48 hours, and 7, 15, and 30 days, the teeth were removed to another container, and the liquid was analyzed. Calcium ion release was measured by atomic absorption spectrophotometry, and pH readings were made with a pH meter. Data were analyzed statistically by analysis of variance and Tukey test (alpha = 0.05). Results: Calcium analysis revealed significant differences (P < .05) for 1% CHX solution and 2% CHX gel at 10 minutes. After 24 hours, 2% CHX gel x Control and 2% CHX gel x 1% CHX solution differed significantly (P < .05). After 48 hours, there were significant differences (P < .05) for 2% CHX gel x Control and Extract x Control. No differences (P > .05) were observed among groups in the other periods. Regarding the pH, there were significant differences (P < .05) for 2% CHX gel x Control and 2% CHX gel x 1% CHX solution after 48 hours and for 2% CHX gel x Control after 15 days. In the other periods, no differences (P > .05) were observed among groups. Conclusions: All pastes behaved similarly in terms of pH and calcium ion release in the studied periods. (J Endod 2009;35:1274-1277)
Resumo:
This study evaluated the presence of residues after removal of calcium hydroxide [Ca(OH)2] associated with different vehicles. Thirty single-rooted teeth were instrumented to a master apical file #25 using 2.5% NaOCl as main irrigant and 17% trisodium EDTA (ethylenediaminetetraacetic acid) as final agent irrigant. Then, the root canals were dressed with Ca(OH)2 associated with silicone oil (Group 1), 2% chlorhexidine gluconate (Group 2), or propylene glycol (Group 3). After coronal sealing, all teeth were kept in a moist environment at room temperature. After 7 days, the teeth were reopened and medicaments were removed using 5 mL of saline solution and instrumentation with master apical file followed by new irrigation with 5 mL of 2.5% NaOCl. Subsequently, teeth were split longitudinally and assessed by scanning electron microscopy. The wall cleanliness of the cervical and apical thirds of the roots were evaluated and scored by three blinded examiners. Statistical analysis was performed using KruskalWallis and Wilcoxon tests at 5% level of significance. All roots had residues of Ca(OH)2 on the canal walls. All experimental groups had similar results (P > 0.05) regardless of the third evaluated. There was significant difference between the apical and cervical thirds only in Group 3 (P < 0.05). Association of different vehicles to Ca(OH)2 does not influence the persistence of residues on the root canal walls. Microsc. Res. Tech. 2012. (C) 2012 Wiley Periodicals, Inc.