41 resultados para PH measurements


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to determine the antioxidant activity of Moringa (Moringa oleifera Lam.) leaves flour in beef burger during storage for 120 days. Six hamburger formulations were processed: one control (without the use of additives), four with addition of Moringa leaves flour (0.10, 0.15, 0.20, and 0.25 g/100 g aggregate), and one with addition of synthetic antioxidant Propyl Gallate (0.01 g/100 g aggregate). The products were analyzed for their chemical composition with determinations of moisture, protein, dietary fiber, lipids, ash, carbohydrate, and caloric value after preparation. Microbiological and acceptance testing were performed at the beginning and after 120 days of storage. Determination of pH, instrumental color and lipid oxidation (TBARS) were performed at 1, 30, 60, 90 and 120 days of storage. All samples showed physical-chemical and microbiological tests in accordance with the Brazilian legislation. pH measurements were between 5.48 and 5.90; however, the intensity of red has changed according to the treatments and storage periods. The addition of Moringa leaves flour had no antioxidant effect on burgers, but its inclusion not only contributed to the improvement of nutritional quality, but also did not harm product acceptance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordination compounds of trivalent lanthanides cations with diphenylphosphinate are originated from direct reaction between a lanthanide salt and diphenylphosphinic acid. These complexes have peculiar and intriguing features, as (i) quickly obtainment through wet process precipitation, (ii) appreciable thermal stability, similar to inorganic phosphates, (iii) polymeric structure, and consequently, (iv) low solubility in both polar and non-polar solvents. Nowadays, coordination polymers are classified as coordination networks or, in case of porous materials, as metal-organic frameworks (MOFs). By this study, we aim to determine some optical properties of rare-earth diphenylphosphinate (RE = La3+, Eu3+, Gd3+, Lu3+) and conduct an updated classification of these compounds, bringing more details of its structure and the possible proposal of new materials with applications in lighting, detection of ionizing radiation and magnetism. The complexes of trivalent rare-earth cation with diphenylphosphinate were prepared by direct mixture of diphenylphosphinic acid with rare-earth metal chloride, both in ethanolic solution. The solution of diphenylphosphinic acid was kept in a beaker under constant stirring with pH measurements of the solution and gadolinium chloride solution was then dripped slowly with the aid of a burette until its complete addition; the following metal:ligand molar ratios were tested: 1:1, 1:2, 1:3, 2:1 e 3:1. The compounds were characterized by spectroscopic and structural techniques. By Fourier Transform Infrared Spectroscopy (FT-IR), it was possible to check the total ionization of diphenylphosphinic acid in synthesized complexes, confirmed by the absence of the band type A, B, C related to ѵ(O-H) of the acid (2663 cm-1, 2168 cm-1, 1684 cm-1), as well as the disappearance of ѵ(P-OH)=961 cm-1. Furthermore, the occurrence of bands shifts of ѵ(POO-) [symmetrical and asymmetrical] of...

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We combine the D0 measurement of the width difference between the light and heavy B-s(0) mass eigenstates and of the CP-violating mixing phase determined from the time-dependent angular distributions in the B-s(0)-> J/psi phi decays along with the charge asymmetry in semileptonic decays also measured with the D0 detector. With the additional constraint from the world average of the flavor-specific B-s(0) lifetime, we obtain Delta Gamma(s)equivalent to(Gamma(L)-Gamma(H))=0.13 +/- 0.09 ps(-1) and vertical bar phi(s)vertical bar=0.70(-0.47)(+0.39) or Delta Gamma(s)=-0.13 +/- 0.09 ps(-1) and vertical bar phi(s)vertical bar=2.44(-0.39)(+0.47). The data sample corresponds to an integrated luminosity of 1.1 fb(-1) accumulated with the D0 detector at the Fermilab Tevatron Collider.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We combine measurements of the top quark pair production cross section in p (p) over bar collisions in the l + jets, ll, and tau l final states ( where l is an electron or muon) at a center of mass energy of root s = 1.96 TeV in 1 fb(-1) of data collected with the D0 detector. For a top quark mass of 170 GeV/c(2), we obtain sigma(t (t) over bar) = 8.18(-0.87)(+0.98) pb in agreement with the theoretical prediction. Based on predictions from higher order quantum chromodynamics, we extract a mass for the top quark from the combined t (t) over bar cross section, consistent with the world average of the top quark mass. In addition, the ratios of t (t) over bar cross sections in different final states are used to set upper limits on the branching fractions B(t -> H(+)b -> tau(+) vb) and B(t -> H(+)b -> c (s) over barb) as a function of the charged Higgs boson mass.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The structure of crotapotin, a protein extracted from the venom of the Crotalus durissus terrificus, in solution at pH = 1.5, was studied by SAXS. The experimental results yield structural parameter values of the molecular radius of gyration R(g) = 13.6 angstrom, volume v = 16.2 x 10(3) angstrom3 and maximal dimension D(max) = 46 angstrom. The distance distribution function deduced from the scattering measurements is consistent with an overall molecular shape of an oblate ellipsoid of revolution with assymetry parameter nu = 0.45.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To determine the effects of storage of arterial and venous blood samples in ice water on blood gas and acid-base measurements.Design: Prospective, in vitro, laboratory study.Setting: School of veterinary medicine.Subjects: Six healthy dogs.Measurements and main results: Baseline measurements of partial pressure of oxygen (PO2), partial pressure of carbon dioxide (PCO2), pH, hemoglobin concentration (tHb), oxyhemoglobin saturation, and oxygen content (ContO(2)) were made. Bicarbonate (HCO3) and standard base excess (SBE) were calculated. Arterial and venous blood samples were separated into 1 and 3 mL samples, anaerobically transferred into 3 mL plastic syringes, and stored in ice water for 6 hours. Measurements were repeated at 15, 30 minutes, and 1, 2, 4, and 6 hours after baseline measurements. Arterial (a) PO2 increased significantly from baseline after 30 minutes of storage in the 1 mL samples and after 2 hours in the 3 mL samples. Venous (v) PO2 was significantly increased from baseline after 4 hours in the 1 mL samples and after 6 hours in the 3 mL samples. The pHa significantly decreased after 2 hours of storage in the 1 mL samples and after 4 hours in the 3 mL samples. In both the 1 and 3 mL samples, pHv decreased significantly only after 6 hours. Neither the arterial nor the venous PCO2 values changed significantly in the 1 mL samples and increased only after 6 hours in the 3 mL samples. No significant changes in tHb, ContO(2), SBE, or HCO3 were detected.Conclusions: the PO2 of arterial and venous blood increased significantly when samples were stored in plastic syringes in ice water. These increases are attributable to the diffusion of oxygen from and through the plastic of the syringe into the blood, which occurred at a rate that exceeded metabolic consumption of oxygen by the nucleated cells.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fireflies emit flashes in the green-yellow region of the spectrum for the purpose of sexual attraction. The bioluminescence color is determined by the luciferases. It is well known that the in vitro bioluminescence color of firefly luciferases can be shifted toward the red by lower pH and higher temperature; for this reason they are classified as pH-sensitive luciferases. However, the mechanism and structural origin of pH sensitivity in fireflies remains unknown. Here we report the cloning of a new luciferase from the Brazilian twilight active firefly Macrolampis sp2, which displays an unusual bimodal spectrum. The recombinant luciferase displays a sensitive spectrum with the peak at 569 nm and a shoulder in the red region. Comparison of the bioluminescence spectra of Macrolampis, Photinus and Cratomorphus firefly luciferases shows that the distinct colors are determined by the ratio between green and red emitters under luciferase influence. Comparison of Macrolampis luciferase with the highly similar North American Photinus pyralis luciferase (91%) showed few substitutions potentially involved with the higher spectral sensitivity in Macrolampis luciferase. Site-directed mutagenesis showed that the natural substitution E354N determines the appearance of the shoulder in the red region of Macrolampis luciferase bioluminescence spectrum, helping to identify important interactions and residues involved in the pH-sensing mechanism in firefly luciferases. © 2005 American Society for Photobiology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Euphorbia tirucalli Lineu (Aveloz) belongs to the family Euphorbiaceae and is used in the treatment of cancer and warts. Some studies have reported that phorbol esters are the active principles responsible for the antitumor activity of Aveloz. The production of these molecules occurs in greater quantity in May, during the morning. This study aimed to evaluate whether the physico-chemical parameters of Aveloz homeopathic aqueous solutions such as pH, electrical conductivity and refractive index change due to storage time. Such parameters were measured regularly for 180 days. All solutions were prepared according to the method of grinding with lactose and subsequent dissolution in aqueous medium, as described in the Brazilian Homeopathic Pharmacopoeia, using as starting point the Aveloz latex collected in May. Homeopathic aqueous solutions containing only lactose were also prepared and evaluated as a control group. The potencies that were analyzed for electrical conductivity, pH and refractive index were: 4cH, 7cH, 9cH, 12cH, 14cH, 15cH, 29cH, 30cH. As a result, we found out that there was only statistical difference (p=0.035) in electrical conductivity between the homeopathic solutions containing Aveloz and the homeopathic solutions without Aveloz, when 15cH potency was compared. We also observed that the electrical conductivity increased with the aging of the solutions but is not directly related to the pH or the refractive index of the solutions, indicating that the aging process may alter the electrical conductivity of the homeopathic medicines. The presence of gas inside the glass that stores these solutions may affect the electrical conductivity measurements. Finally, no statistically significant difference was observed (p> 0.05) in the pH and refractive index.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report the combination of recent measurements of the helicity of the W boson from top quark decay by the CDF and D0 collaborations, based on data samples corresponding to integrated luminosities of 2.7-5.4fb -1 of pp̄ collisions collected during Run II of the Fermilab Tevatron collider. Combining measurements that simultaneously determine the fractions of W bosons with longitudinal (f 0) and right-handed (f +) helicities, we find f 0=0.722±0.081[±0.062(stat)±0.052(syst)] and f +=-0.033±0.046[±0.034(stat)±0.031(syst)]. Combining measurements where one of the helicity fractions is fixed to the value expected in the standard model, we find f 0=0.682±0. 057[±0.035(stat)±0.046(syst)] for fixed f + and f +=-0.015±0.035[±0.018(stat)±0.030(syst)] for fixed f 0. The results are consistent with standard model expectations. © 2012 American Physical Society.