117 resultados para OSTEOTOMY
Resumo:
In maxillary Le Fort I type osteotomy the detachment of the nasal mucosa should be done carefully. Piezoelectric surgery contributed much to increase the safety of osteotomies, despite the initial advantage of minimizing the risk of injury in nervous tissue, mainly in bilateral sagittal split osteotomy; we use the piezoelectric device for the initial detachment of the nasal mucosa in the maxillary osteotomy.
Resumo:
This case report is an 8-year follow-up of a malpositioned single implant, which was treated with segmental osteotomy, to confirm the treatment's characteristics, indications, and advantages. Deep buccal positioning of an endosseous implant placed in the maxillary left central incisor area did not permit acceptable prosthetic rehabilitation, despite its favorable bone insertion with no significant marginal bone loss. The surgical procedure included osteotomy and block movement performed toward the lingual and cervical position, fixed with a provisional prosthesis and miniplates and mini-implants. A connective tissue graft was necessary for esthetics optimization and was performed in a second stage. Advantages including the prevention of alveolar ridge damage, the improvement of gingival contour, and the use of an already integrated implant are presented. Clinically satisfactory hard and soft tissue stability permitted us to consider segmental surgery as a reliable alternative for malpositioned osseointegrated implants.
Resumo:
Introduction The Le Fort I osteotomy is indicated to reposition the maxilla in the surgical correction of dentofacial deformities. Although it is a known surgical step, like any surgical procedure, it can have complications and difficulties; among these, the initial mobility of the jaw is very common after completing all corticotomies. Methods The authors present a technique in which the bite fork is used as an auxiliary tool in maxilla downfracture, especially in cases of maxillary impaction where vertical space is created on the walls of the corticotomy. Findings As the bite fork acts as a scraper with a long leverage arm, an advantage would be the better distribution of forces along the corticotomy, minimizing the risk of bad fracture and facilitating maxillary downfracture movement.
Resumo:
Excessive mechanical stress due to caudal sloping of the tibial plateau may result In early breakdown of the cranial cruciate ligament (CrCL). Five dogs with CrCL rupture associated with caudal sloping of the proximal tibial plateau are described. All were small dogs, of between three and six years of age, with a mean bodyweight of 9.3 kg, which had acute hindlimb lameness. Radiographic examination revealed cranial displacement of the tibia, with a tibial angle varying from 58 to 60 degrees. All cases were treated with a lateral fabellotibial suture and cranial cuneiform osteotomy of the proximal tibia. All dogs were using the operated limb three days after surgery, with normal gait re-established after a mean period of 10 days. Excessive tibial plateau sloping is not a frequent cause of hindlimb lameness In small animals, although it Is Important to consider it as a predisposing factor for rupture of the CrCL.
Resumo:
O objetivo do presente trabalho foi o de estudar a resistência à corrosão em placas de aço inoxidável 316L, com diferentes tipos de acabamento e tratamento superficial, e a possível interferência dessa reação corrosiva na consolidação óssea. Utilizaram-se placas semi-acabadas, polidas, tratadas com jatos de microesferas de vidro e passivadas, as quais foram aplicadas na epífise distal do rádio de cães. Foram utilizados 12 animais, divididos em dois grupos, nos quais, após osteotomia bilateral do rádio e ulna, foram realizadas osteossínteses do rádio, totalizando 24 procedimentos. Avaliou-se a evolução clínica e radiográfica das regiões que receberam os implantes aos 30, 60, 90, 180, 240 e 360 dias. Os animais do grupo 1 (GI) foram sacrificados aos 180 dias e os do GII aos 360 dias para estudo histológico e de microscopia eletrônica de varredura do local da osteotomia sob a região dos implantes metálicos e para estudo da resistência à corrosão no organismo, pelos implantes metálicos, por meio de análises química e metalográfica (microscopia óptica e eletrônica de varredura e espectroscopia de espalhamento de energia por raios X). Os animais recuperaram a função dos membros operados 24 horas após a cirurgia. Radiograficamente, verificou-se a consolidação óssea em todos os animais. Macro e microscopicamente não foram observados sinais de corrosão nos implantes metálicos, exceto em uma placa passivada, aplicada no rádio esquerdo de um animal, na qual a corrosão foi detectada pela microscopia óptica e eletrônica de varredura. Este estudo permite concluir que as placas de aço inoxidável 316L, independente do acabamento superficial a que foram submetidas, não sofreram corrosão ou reações adversas e foram efetivas no tratamento das fraturas experimentais do rádio e ulna de cães.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to clinically and radiographically evaluate acute bone shortening followed by gradual lengthening in the treatment of large segmental tibia defects induced in seven clinically normal dogs. A circular external fixator was assembled with one proximal 5/8-circle ring, one middle ring and one distal ring connected with three rods. Thirty per cent of the tibia and fibula were removed in the middle and distal parts of the diaphyses, between the middle and distal rings. Acute bone shortening with compression of proximal and distal segments was performed. A subperiosteal osteotomy was performed between the half-ring and middle ring. Bone distraction started 7 days after surgery; after lengthening, the apparatus was left in place for 14 weeks for consolidation of regenerated bone. The frame was removed at the end of this period, and the dogs observed for four more weeks. Functional results were considered excellent in two, good in three and fair in the other two dogs. Bone regeneration within the distraction gap was obtained 14 weeks after neutral fixation period. We concluded that acute bone shortening followed by gradual lengthening by Ilizarov method can be used to treat extensive tibial defects in dogs, although it presents limb temporary abnormal limb shape and unequal length as early disadvantages.
Resumo:
O objetivo do estudo foi analisar histologicamente a qualidade, tipo e orientação dos tecidos formados na área de regeneração óssea produzida durante alongamento simultâneo do rádio e da ulna, com fixador externo de Ilizarov, a partir de osteotomia subperiosteal diafisária distal, com dois incrementos diários de 0,5 mm. A montagem foi composta de dois anéis e quatro hastes telescópicas, sendo a distração óssea iniciada no sexto dia de pós-operatório. Utilizaram-se 15 cães, sem raça definida, adultos, com peso corpóreo entre 17 e 30 kg, divididos por sorteio em subgrupos (A, B, C, D e E) compostos por três animais, que foram submetidos a eutanásia após os seguintes procedimentos: A- oito dias de alongamento, B- 15 dias de alongamento, C- 22 dias de alongamento, D- 28 dias de alongamento e oito dias de fase neutra com o fixador, E- 28 dias de alongamento, 60 dias de fase neutra com fixador e 45 dias sem fixador. Os resultados obtidos mostram que o tipo e localização da osteotomia, bem como o ritmo de distração utilizado, não interferiram sobremaneira na regeneração óssea. A reparação óssea foi eficiente, notadamente intramembranosa, contudo nos subgrupos B e C foi observada a presença de cartilagem.
Resumo:
OBJETIVO: Avaliar o método de Ulson de fixação intramedular associado à fixação externa variando a altura do travamento externo dos fios de Kirschner e sem fixação externa. MÉTODO: Foram utilizadas 18 tíbias de porcos, sendo realizada osteotomia transversal na região da tuberosidade e introduzidos dois fios de Kirschner intramedulares em cada peça, em três diferentes padrões de montagem: grupo I - travamento com minifixador externo com 3,0cm de altura; grupo II - travamento com 4,5cm de altura; grupo III: sem travamento externo. Realizaram-se ensaios mecânicos de cisalhamento, obtendo-se: carga máxima, limite de proporcionalidade e coeficiente de rigidez. RESULTADOS: Não foram encontradas diferenças significativas de carga máxima e limite de proporcionalidade entre os grupos; o grupo II apresentou maior coeficiente de rigidez. CONCLUSÃO: A altura do travamento dos fios de Kirschner no método de Ulson, dentro dos limites avaliados, não prejudicou a estabilidade do sistema de fixação da fratura.
Resumo:
Background: This prospective experimental study evaluated the surgical procedure and results of modular hybrid total hip arthroplasty in dogs.Methods: Ten skeletally mature healthy mongrel dogs with weights varying between 19 and 27 kg were used. Cemented modular femoral stems and uncemented porous-coated acetabular cups were employed. Clinical and radiographic evaluations were performed before surgery and at 30, 60, 90, 120, 180 and 360 days post-operation.Results: Excellent weight bearing was noticed in the operated limb in seven dogs. Dislocation followed by loosening of the prosthesis was noticed in two dogs, which were therefore properly treated with a femoral head osteotomy. Femoral fracture occurred in one dog, which was promptly treated with full implant removal and femoral osteosynthesis.Conclusions: The canine modular hybrid total hip arthroplasty provided excellent functionality of the operated limb.
Modified stabilization method for the tibial tuberosity advancement technique: a biomechanical study
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Two birds were presented with malunion fractures. The first was a young toco toucan (Ramphastos toco) with malunion of the tarsometatarsus that was treated by an opening-corrective osteotomy and an acrylic-pin external skeletal fixator (type II) to stabilize the osteotomy. The second bird was m adult southern caracara (Caracara plancus) with radial and ulnar malunion that was treated by closing-wedge osteotomies. Stabilization of the osteotomy sites was accomplished through 1 bone plate fixed cranially on the ulna with 6 cortical screws and an interfragmentary single wire in radius. In both cases, the malunion was corrected, but the manus of the southern caracara was amputated because of carpal joint luxation that induced malposition of the feathers.
Resumo:
Há evidências de que o ultrassom (US) de baixa intensidade pode acelerar a regeneração óssea. Este trabalho objetivou verificar a ação do US no defeito ósseo, criado experimentalmente em tíbias de ratos sob ausência de carga. Vinte Rattus novergicus albinus, Wistar adultos, divididos em: G1 (n=10), grupo experimental de 15 dias sem suspensão, e G2 (n=10), grupo experimental de 15 dias suspenso pela cauda, foram submetidos à osteotomia em ambas as tíbias e à aplicação do US, frequência de 1,5 MHz, ciclo de trabalho 1:4, 30 mW/cm², nas tíbias direitas por 12 sessões de 20 minutos. Após o sacrifício, as tíbias foram submetidas à análise da Densidade Mineral Óssea (DMO). Os resultados demonstraram DMO de 0,139±0,018 g/cm² para tíbia tratada; 0,131±0,009 g/cm² para tíbia controle no G1; e no G2 registrou-se 0,120±0,009 g/cm² para tíbia tratada e 0,106±0,017 g/cm² para tíbia controle. Houve diferença significante entre os grupos nos quais o G2 apresentou menor DMO, o que demonstra que a suspensão prejudica a manutenção das propriedades ósseas, e entre as tíbias tratadas e controles do G2, demonstrando que o US acelerou o processo de reparo, concluindo que a impossibilidade do estímulo mecânico causada pela não deambulação em um processo de reparo ósseo pode ser minimizada pela ação do US. No G1, a aplicação do US não teve influência significante no aumento da DMO, talvez pelo fato dos animais já terem estímulo mecânico suficiente à formação óssea.