31 resultados para Multidimensional projection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the dynamics of a system of interacting spins described by the Ginzburg-Landau Hamiltonian. The method used is Zwanzig's version of the projection-operator method, in contrast to previous derivations in which we used Mori's version of this method. It is proved that both methods produce the same answer for the Green's function. We also make contact between the projection-operator method and critical dynamics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We give a multidimensional extension of a one-dimensional integral inequality due to F. Carlson. The extension presented here involves Lp spaces with mixed norms in a very natural way. © 1984.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a method to recover 3D geometry of Lambertian surfaces by using multiple images taken from the same view point and with the scene illuminated from different positions. This approach differs from Stereo Photometry in that it considers the light source at a finite distance from the object and the perspective projection in image formation. The proposed model allows local solution and recovery of 3D coordinates, in addition to surface orientation. A procedure to calibrate the light sources is also presented. Results of the application of the algorithm to synthetic images are shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. It has been suggested that the study of women who survive life-threatening complications related to pregnancy (maternal near-miss cases) may represent a practical alternative to surveillance of maternal morbidity/mortality since the number of cases is higher and the woman herself is able to provide information on the difficulties she faced and the long-term repercussions of the event. These repercussions, which may include sexual dysfunction, postpartum depression and posttraumatic stress disorder, may persist for prolonged periods of time, affecting women's quality of life and resulting in adverse effects to them and their babies. Objective. The aims of the present study are to create a nationwide network of scientific cooperation to carry out surveillance and estimate the frequency of maternal near-miss cases, to perform a multicenter investigation into the quality of care for women with severe complications of pregnancy, and to carry out a multidimensional evaluation of these women up to six months. Methods/Design. This project has two components: a multicenter, cross-sectional study to be implemented in 27 referral obstetric units in different geographical regions of Brazil, and a concurrent cohort study of multidimensional analysis. Over 12 months, investigators will perform prospective surveillance to identify all maternal complications. The population of the cross-sectional component will consist of all women surviving potentially life-threatening conditions (severe maternal complications) or life-threatening conditions (the maternal near miss criteria) and maternal deaths according to the new WHO definition and criteria. Data analysis will be performed in case subgroups according to the moment of occurrence and determining cause. Frequencies of near-miss and other severe maternal morbidity and the association between organ dysfunction and maternal death will be estimated. A proportion of cases identified in the cross-sectional study will comprise the cohort of women for the multidimensional analysis. Various aspects of the lives of women surviving severe maternal complications will be evaluated 3 and 6 months after the event and compared to a group of women who suffered no severe complications in pregnancy. Previously validated questionnaires will be used in the interviews to assess reproductive function, posttraumatic stress, functional capacity, quality of life, sexual function, postpartum depression and infant development. © 2009 Cecatti et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the development of an multi-projection stereoscopic dental arches application with semantic descriptions. The first section presents the concepts of the used technologies. Applications and examples are demonstrated. Finally, is presented the physical structure and the developed system, where a 3D dental arch is used as a model and can be viewed in multi-projection, thereby, providing greater user's immersion. ©2010 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: A scale validated in one language is not automatically valid in another language or culture. The purpose of this study was to validate the English version of the UNESP-Botucatu multidimensional composite pain scale (MCPS) to assess postoperative pain in cats. The English version was developed using translation, back-translation, and review by individuals with expertise in feline pain management. In sequence, validity and reliability tests were performed.Results: Of the three domains identified by factor analysis, the internal consistency was excellent for 'pain expression' and 'psychomotor change' (0.86 and 0.87) but not for 'physiological variables' (0.28). Relevant changes in pain scores at clinically distinct time points (e.g., post-surgery, post-analgesic therapy), confirmed the construct validity and responsiveness (Wilcoxon test, p < 0.001). Favorable correlation with the IVAS scores (p < 0.001) and moderate to very good agreement between blinded observers and 'gold standard' evaluations, supported criterion validity. The cut-off point for rescue analgesia was > 7 (range 0-30 points) with 96.5% sensitivity and 99.5% specificity.Conclusions: The English version of the UNESP-Botucatu-MCPS is a valid, reliable and responsive instrument for assessing acute pain in cats undergoing ovariohysterectomy, when used by anesthesiologists or anesthesia technicians. The cut-off point for rescue analgesia provides an additional tool for guiding analgesic therapy. © 2013 Brondani et al.; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Matematica Aplicada e Computacional - FCT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study focused on the validation of the Spanish version of the UNESP-Botucatu multidimensional composite pain scale to assess postoperative pain in cats. The original scale in Portuguese was translated into Spanish by two independent translators, and summarised in one version by a third individual. The summarised version was back-translated and minor adjustments were made. The scale was reviewed by three anesthesiologists with Spanish as their first language, and the final version was submitted to psychometric testing. Thirty cats undergoing ovariohysterectomy were video recorded during the perioperative period. Six observers from different spanish speaking countries, who had Spanish as the first language watched the videos and determined the pain scores using the Spanish version of the scale, identifying the cats that should receive analgesics. Videos were reanalysed in a different order about 2 months after the first assessment. The sensitivity to change, content and construct validity were established by the significant change in pain scores in response to surgery and analgesics. The agreement between the evaluations of the 'gold standard'(researcher that developed the scale) and the other observers confirmed the criterion validity. Inter- and intra-rater reliability, evaluated by intra-class correlation coefficient, ranged from good to very good for all scale items. The cut-off point for rescue analgesia identified by Receiver Operating Characteristic curve was > 7 with 92% of sensitivity and 91% of specificity. The Spanish version of the UNESP-Botucatu multidimensional composite pain scale is interpretable (has an optimal analgesic intervention score), valid and reliable instrument for assessing acute pain in cats undergoing ovariohysterectomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Física - IFT