127 resultados para Monodispersed spheres


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We placed spheres of synthetic hydroxyapatite (calcium chloride combined with sodium phosphate) in the eviscerated or enucleated orbital cavity of rats in order to evaluate the biocompatibility of this material with the orbital cavity. The study was conducted on 50 albino rats, 25 of which were submitted to enucleation and 25 to evisceration of one eye. The animals were sacrificed 7, 15, 21, 30 and 60 days after surgery and the orbital content was submitted to histopathological examination. A reaction of the young granulation tissue type was observed first. The hydroxyapatite was gradually surrounded by a granulomatous macrophage inflammatory response and covered with dense connective tissue that formed a sort of mesh septating and supporting progressively smaller blocks of the substance. The same type of reaction was observed in the enucleated and eviscerated cavities. We conclude that synthetic hydroxyapatite is an inert nonallergenic material which is appropriate for volume replacement in the anophthalmic cavity

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Comparar implantes de polietileno poroso no estado sólido e gel em cavidades enucleadas. MÉTODOS: Trinta e seis coelhos albinos foram submetidos à enucleação do olho direito, recebendo esferas de polietileno poroso (18 animais) ou gel (18 animais), de 12 mm de diâmetro. Os animais foram avaliados semanalmente por exame clínico e mensalmente por ultra-sonografia modo B, realizada 30, 60 e 90 dias após a cirurgia, tendo sido os animais sacrificados aos 90 dias. Após o sacrifício, o conteúdo orbitário foi removido e examinado histologicamente. RESULTADOS: Cinco animais (27,2%) que receberam os implantes de polietileno poroso tiveram extrusão do implante. Houve extrusão em 94,4% dos animais que receberam a esfera de polietileno gel, tendo-se observado que o diâmetro das esferas gel extruídas encontrava-se aumentado em relação ao diâmetro da esfera implantada. A ultra-sonografia mostrou que o implante de polietileno poroso se vascularizou e que o gel não, o que foi confirmado pelo exame histológico. CONCLUSÃO: Esferas de polietileno no estado gel sofrem hidratação e aumentam de volume, sendo necessário conhecer o seu tamanho final antes da implantação. A ultra-sonografia permite conhecer a vascularização do implante, podendo ser usada na avaliação da integração esfera-hospedeiro.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar e comparar a biocompatibilidade de esferas de silicone gelatinosas e rígidas em cavidades evisceradas de coelhos. MÉTODOS: Trinta coelhos tiveram o olho direito eviscerado com implantação de esferas de silicone gelatinosas (Grupo I) ou rígidas (Grupo II). Foi realizada avaliação clínica diária, ultrassonografia da cavidade orbitária, análise histológica e morfométrica da pseudocápsula que se formou ao redor dos implantes aos 7, 30 e 90 dias após a cirurgia, com avaliação estatística dos resultados. RESULTADOS: Houve boa integração das esferas com os tecidos orbitários e semelhança de resposta tecidual com ambas as esferas. Duas esferas de silicone gelatinosas e uma rígida extruíram. A pseudocápsula que se formou ao redor das esferas gelatinosas foi mais organizada, com espessura e reação inflamatória menores que a observada nas esferas rígidas. CONCLUSÕES: Esferas de silicone gelatinosas e rígidas tiveram boa integração tecidual em cavidades evisceradas de coelhos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound.METHODS: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery.RESULTS: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27.8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues.CONCLUSION: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provides useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation,

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o volume orbitário de coelhos recém-nascidos, enucleados ou eviscerados, sem ou com reposição do volume orbitário por esferas de polietileno poroso de 10 mm, usando a tomografia computadorizada, o teste de deslocamento de água e a medida da abertura orbitária por Image-J. MÉTODOS: Estudo experimental, usando 48 coelhos albinos, com idade de 42 dias, submetidos à evisceração ou enucleação, com implante de esfera de polietileno poroso de 10 mm de diâmetro ou sem implante. O lado esquerdo não foi submetido à cirurgia e foi usado como controle. Após 1, 3 e 6 meses, foram sacrificados quatro animais de cada grupo. Os crânios foram preparados para estudo do osso seco por maceração da peça, e analisados em relação ao volume orbitário por tomografia computadorizada, teste de deslocamento de água e avaliação da abertura orbitária usando o software Image-J. RESULTADOS: O volume das órbitas enucleadas ou evisceradas, com ou sem o uso do implante não apresentaram diferenças estatisticamente significativas (p<0,05) entre si, quando avaliadas por tomografia computadorizada, pelo teste de deslocamento de água e pelo Image-J. CONCLUSÃO: O desenvolvimento orbitário de coelhos com idade superior a 42 dias de vida não se altera quando se opta pela enucleação ou pela evisceração, ou quando se utiliza ou não implantes orbitários. O teste de deslocamento de água apresentou resultados semelhantes aos fornecidos pela tomografia, sugerindo-se sua utilização em experimentação científica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: Apresentar as complicações observadas com esferas de diferentes materiais na reconstrução da cavidade anoftálmica. Métodos: Foram avaliados retrospectivamente 117 portadores de cavidade anoftálmica, com tempo mínimo de seguimento de 6 meses, procurando correlacionar sexo, tipo de esfera utilizada, causa da perda do olho, diâmetro da prótese, tipo de cirurgia e a ocorrência das complicações (deiscências e expulsão da esfera). Resultados: As deiscências ocorreram principalmente com esferas de polímero vegetal. A expulsão da esfera ocorreu mais precocemente nos implantes integráveis e foi mais freqüente com as esferas não-integráveis (PMMA). A esfera de polietileno (Polipore) foi a que apresentou menos probabilidade de complicações. Conclusão: A esfera de polietileno é na atualidade a melhor alternativa para preenchimento da cavidade anoftálmica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Synthetic hydroxyapatite and porous polyethylene (Polipore) spheres were placed in rabbits' eviscerated cavities to evaluate tissue reaction and volume maintenance.Methods. Fifty-six Norfolk albino rabbits underwent unilateral evisceration and implantation of synthetic hydroxyapatite (H group, 28 animals) or porous polyethylene spheres (P group, 28 animals). Postoperative reactions, animal behavior, and socket conditions were monitored. Light microscopy and morphometric evaluation with statistical analysis of the exenterated orbits were performed at 7, 15, 30, 60, 90, 120, and 180 days. Scanning electron microscopy was appraised 7, 60, and 180 days after surgery.Results: Two animals from the H group and 1 from the P group had extrusion 7 days after surgery. Throughout the experimental period, the synthetic hydroxyapatite caused more inflammation than the porous polyethylene material. Ingrowth in the sphere occurred 7 to 15 days after the surgery in both groups, and the tissue reaction became denser at approximate to60 to 90 days, when bony metaplasia began in the H group. Volume maintenance was better in the P group and with a smaller pseudocapsule surrounding the implanted sphere than in the H group.Conclusions: Clinical findings demonstrated mild inflammation inside the sphere and in the pseudocapsule surrounding it and better cavity volume maintenance in the P group animals. The authors consider porous polyethylene a more suitable material than synthetic hydroxyapatite for use in anophthalmic cavity reconstruction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A auditoria, na saúde, verifica os processos e resultados da prestação de serviços, pressupondo o desenvolvimento de um modelo de atenção adequado, de acordo com as legislações vigentes. Nesta pesquisa, objetivou-se analisar as atividades da auditoria no Sistema Único de Saúde no serviço de saúde bucal, buscando demonstrar as ações e a sua inserção nas três esferas de governo. Foram realizadas análise documental e levantamentos bibliográficos sobre os sistemas de auditoria e o papel do auditor no serviço odontológico desde 1969. Os resultados mostraram que foram encontrados seis artigos sobre auditoria odontológica no SUS e que a atuação do auditor odontológico é abrangente no gerenciamento do sistema, consistindo no controle, na avaliação, na supervisão e na orientação, bem como na garantia da participação social e acesso aos serviços. Na saúde bucal o auditor analisa, monitora e fiscaliza o planejamento das estratégias e os procedimentos efetuados; realiza o cadastramento dos profissionais, das unidades de saúde e a programação física orçamentária; viabiliza os dados para o sistema de informação e o pagamento dos serviços prestados; examina o cumprimento das pactuações, dando um enfoque educativo e não mais policialesco à resolubilidade dos problemas. Conclui-se que existem poucos estudos sobre auditoria odontológica no SUS e que o sistema de auditoria é um instrumento administrativo confiável e essencial para os gestores no desenvolvimento das ações de saúde.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este artigo apresenta as conseqüências do Programa Dinheiro Direto na Escola para a esfera da gestão das escolas públicas, especialmente aquelas relativas às conexões entre a constituição e gestão da esfera pública e da esfera privada. de certa forma, acreditamos que o PDDE materializa mudanças ocorridas no papel do Estado. Os resultados encontrados, com destaque para aqueles que envolveram a indução à criação de unidades de direito privado para o recebimento e gestão dos recursos descentralizados, organizam-se a efeito deste artigo, tendo em vista três aspectos constitutivos da gestão educacional: a democratização da gestão da escola, a relação público e privado e a relação entre descentralização e centralização.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

physical education with a discipline or field has reached the status and scope in all spheres of contemporary culture. Not by chance that issues relating to body and human movement in recent years have been the focus of studies, especially understanding of the need to reflect on new concepts in physical education. Science in the traditional sense, as a method of analysis supports the idea of scientific rigor, but is fundamental reflection. This essay seeks the interface between science and philosophy, on which discussions can take other visibilities in physical education as an activity of the culture. With interdisciplinary approaches and thinking about body movement, focus on scientific concepts and philosophical traverse historically a possible way to rethink the design physical education.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the absence of the queen, a few workers of F. s. languida developed their ovaries forming nevertheless, only one follicle with a single oocyte which was unable to form yolk spheres. They never showed signals of degeneration or resorption. The corpora allata were homogeneous during all the 5 months of orphanage studied. Its activity might be low but constant, able to maintain the follicle entire, but unable to promote the yolk spheres assembly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The synthesis and characterization of CuO flower-nanostructure processed in domestic hydrothermal microwave oven was presented. Phase analysis was carried out using X-ray diffraction (XRD) and micro-Raman scattering (MRS) and the results confirmed the CuO flower-nanostructure as a single-phase. The field-emission scanning electron microscopy (FEG-SEM) was used to estimate the average spheres diameter while transmission electron microscope (TEM) to observe the thorn of the flower-nanostructures. The mechanism of CuO flower-nanostructures formation is proposed and explained. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This letter reports the synthesis of CuO urchin-nanostructures by a simple and novel hydrothermal microwave method. The formation and growth of urchin-nanostructures is mainly affected by the addition of polyethylene glycol (PEG). The hierarchical malachite particles are uniform spheres with a diameter of 0.7-1.9 mu m. CuO urchin-nano structures were characterized by X-ray diffraction (XRD), field-emission scanning electron microscopy (FEG-SEM) and nitrogen adsorption (BET). The specific surface area of the CuO nanostructured microspheres was about 170.5 m(2)/g. A possible mechanism for the formation of such CuO urchin-nanostructures is proposed. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)