32 resultados para Minorities in medicine


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this paper is to compare the fluoride-releasing and mechanical properties of an experimental luting glass ionomer cement, which has a modified composition and a commercial luting cement. The experimental powder was obtained by sol-gel process and then, it was used to prepare the experimental cements. The properties of cement pastes, such as setting time and working time, microhardness and diametral tensile strength were determined. Fluoride release from GICs was evaluated at time intervals of 1, 7, 14, 21 and 28 days in deionized water. Atomic force microscopy (AFM) analyses showed that the surface of the experimental cements is more homogeneous than commercial GICs. The mechanical properties and the measure of liberation of fluoride of the two cements were influenced by ratio powder:liquid and chemical composition of the precursor powders. Experimental cements released less fluoride than commercial cements. However, this liberation was more constant during the analyzed period. Thus, the results obtained in this study indicated that the composition of the experimental powder modified by the niobium can lead the formation of the polysalt matrix with good mechanical properties. In other words, we can say that experimental powder offered considerable promise for exploitation in dental field.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Titanium alloys are hoped to be used much more for applications as implant materials in the medical and dental fields because of their basic properties, such as biocompatibility, corrosion resistance and specific strength compared with other metallic implant materials. Thus, the Ti-6Al-7Nb alloy that has recently been developed for biomedical use, that is, primarily developed for orthopaedic use, is to be studied in this paper, for application in dental implants. The biocompatibility test in vivo was carried out in dogs and the osseointegration was verified through histological analysis of the samples of the Ti-6Al-7Nb alloy with and without hydroxyapatite coating that were inserted in the alveoli. Within the controlled conditions the samples did not show any toxic effects on the cells. (C) 2001 Kluwer Academic Publishers.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A finite element analysis was carried out to study the role of prefabricated threaded split shaft post (Flexi-Post) on dentinal stress in pulpless tooth. Three dimensional plane strain model of mesio-distal section of a human maxillary central incisor without restoration was analysed with the MSC/NASTRAN (MacNeal/ Schwendler) general purpose finite analysis program was executed on a microcomputer. The model as discretized into 48.954 axisymmetric finite elements defined by 10.355 nodes. Each element was assigned unique elastic properties to represent the materials modeled. Homogeneity, isotropy and linear elasticity were assume for all material. A simulation of static load of 100N was applied to the incisal edge of the post; vertical. Maximal principal stresses and von Mises equivalent stress were calculated. Using the element analysis model employed in this study, the following can be concluded concerning threaded split shaft post (Flexi-Post): Maximum principal stresses in dentin were located at cervical place and at the post apex. The apical threads of the post not redirecting stresses away from the root.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Zinc status was evaluated in 12 hyperthyroid and in 7 hypothyroid patients in comparison with 8 euthyroid individuals by the oral zinc tolerance test and by the determination of urinary zinc excretion. Hyperthyroid patients presented a basal serum concentration similar to that of euthyroid individuals but greater urinary zinc excretion, indicating the occurrence of zinc depletion from tissues to the blood stream caused by the catabolism inherent in the hyperthyroid state. Hyperthyroidism also caused lower zinc assimilation by tissues after zinc ingestion. Hypothyroid individuals present lower basal zinc levels in serum than euthyroid and hyperthyroid individuals and urinary zinc excretion similar to that of euthyroid individuals. No changes in the parameters measured were observed after zinc load, suggesting reduced or delayed intestinal absorption and zinc assimilation by tissues. The present data are indicative of zinc deficiency, the lower intestinal zinc absorption probably being one of the contributing factors.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objectives: To compare simulated periodontal bone defect depth measured in digital radiographs with dedicated and non-dedicated software systems and to compare the depth measurements from each program with the measurements in dry mandibles.Methods: Forty periodontal bone defects were created at the proximal area of the first premolar in dry pig mandibles. Measurements of the defects were performed with a periodontal probe in the dry mandible. Periapical digital radiographs of the defects were recorded using the Schick sensor in a standardized exposure setting. All images were read using a Schick dedicated software system (CDR DICOM for Windows v.3.5), and three commonly available non-dedicated software systems (Vix Win 2000 v.1.2; Adobe Photoshop 7.0 and Image Tool 3.0). The defects were measured three times in each image and a consensus was reached among three examiners using the four software systems. The difference between the radiographic measurements was analysed using analysis of variance (ANOVA) and by comparing the measurements from each software system with the dry mandibles measurements using Student's t-test.Results: the mean values of the bone defects measured in the radiographs were 5.07 rum, 5.06 rum, 5.01 mm and 5.11 mm for CDR Digital Image and Communication in Medicine (DICOM) for Windows, Vix Win, Adobe Photoshop, and Image Tool, respectively, and 6.67 mm for the dry mandible. The means of the measurements performed in the four software systems were not significantly different, ANOVA (P = 0.958). A significant underestimation of defect depth was obtained when we compared the mean depths from each software system with the dry mandible measurements (t-test; P congruent to 0.000).Conclusions: the periodontal bone defect measurements in dedicated and in three non-dedicated software systems were not significantly different, but they all underestimated the measurements when compared with the measurements obtained in the dry mandibles.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Dopamine (DA) and zinc (Zn++) share common mechanisms in their inhibition of prolactin (PRL) secretion. Both substances are present in the same brain areas, where Zn++ is released together with DA, suggesting a modulatory effect of Zn++ on dopaminergic receptors. The aim of the present study was to evaluate the effect of Zn supplementation on basal and PRL secretion stimulated by metoclopramide (MCP), a dopaminergic antagonist. Seven healthy men were evaluated in controlled study, where MCP (5 mg) was given intravenously, before and after 3 months of oral Zn++ (25 mg) administration. Our results indicate that chronic Zn++ administration does not change basal or MCP-stimulated plasma PRL secretion suggesting that, in humans, Zn++ does not interfere on PRL secretion mediated through dopaminergic receptors.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The influence of potential on electrochemical behavior of Ti-6Al-7Nb alloy under simulate physiological conditions was investigated by electrochemical impedance spectroscopy (EIS). The experimental results were compared with those obtained by potentiodynamic polarization curves. All measurements were carried out in Hank's aerated solution at 25degreesC, at pH 7.8 and at different potentials (corrosion potential, 0 mV(SCE), 1000 mV(SCE), and 2000 mV(SCE)). The EIS spectra exhibited a two-step or a two-time constant system, suggesting the formation of a two-layer oxide film on the metal surface. The high corrosion resistance, displayed by this alloy in electrochemical polarization tests, is due to the dense inner layer, while its osseointegration ability can be ascribed to the presence of the outer porous layer. (C) 2004 Kluwer Academic Publishers.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective. The purpose of this study was to evaluate the effect of total abdominal hysterectomy on ovarian blood supply using transvaginal color Doppler ultrasonography in women of reproductive age. Methods. This prospective study included 61 women aged 40 years or younger who were divided into 2 groups: group 1, comprising 31 patients who underwent total abdominal hysterectomy (TAH), and group 2, comprising 30 women with no abnormalities. Inclusion criteria included normal ovarian function at baseline, with basal follicle-stimulating hormone levels of less than 15 mUI/mL, normal body weight, no tobacco use, and no history of laparotomy or ovarian disease. Ovarian arterial blood supply by determination of the pulsatility index (PI) on Doppler analysis and ovarian volume on transvaginal ultrasonography were assessed at baseline and at 6 and 12 postoperative months. The Student t test, profile analysis, and Friedman and Mann-Whitney tests were used in the statistical analysis of data. Results. Statistical analysis of baseline data revealed that both groups were homogeneous. At months 6 and 12, greater ovarian volumes and lower PI values were observed in patients who underwent TAH (P < .05). By the end of the study, in 8 of the 31 patients who underwent TAH (25.5%), benign ovarian cysts were observed. in the control group, all the parameters studied remained unchanged. Conclusions. The reduced PI values observed on Doppler ultrasonography suggested a decrease in the resistance flow in the ovarian arteries in women of reproductive age who underwent TAH.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In recent years, there has been a great interest in the development of biomaterials that could be used in the repair of bone defects. Collagen matrix (CM) has the advantage that it can be modified chemically to improve its mechanical properties. The aim of the present study was to evaluate the effect of three-dimensional membranes of native or anionic (submitted to alkaline treatment for 48 or 96 h) collagen matrix on the consolidation of osteoporosis bone fractures resulting from the gonadal hormone alterations caused by ovariectomy in rats subjected to hormone replacement therapy. The animals received the implants 4 months after ovariectomy and were sacrificed 8 weeks after implantation of the membranes into 4-mm wide bone defects created in the distal third of the femur with a surgical bur. Macroscopic analysis revealed the absence of pathological alterations in the implanted areas, suggesting that the material was biocompatible. Microscopic analysis showed a lower amount of bone ingrowth in the areas receiving the native membrane compared to the bone defects filled with the anionic membranes. In ovariectomized animals receiving anionic membranes, a delay in bone regeneration was observed mainly in animals not subjected to hormone replacement therapy. We conclude that anionic membranes treated with alkaline solution for 48 and 96 h presented better results in terms of bone ingrowth.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Natural or synthetic materials may be used to aid tissue repair of fracture or pathologies where there has been a loss of bone mass. Polymeric materials have been widely studied, aiming at their use in orthopaedics and aesthetic plastic surgery. Polymeric biodegradable blends formed from two or more kinds of polymers could present faster degradation rate than homopolymers. The purpose of this work was to compare the biological response of two biomaterials: poly(L-lactic acid)PLLA and poly(L-lactic acid)PLLA/poly(ethylene oxide)PEO blend. Forty four-week-old rats were divided into two groups of 20 animals, of which one group received PLLA and the other PLLA/PEO implants. In each of the animals, one of the biomaterials was implanted in the proximal epiphysis of the right tibia. Each group was divided into subgroups of 5 animals, and sacrificed 2, 4, 8 and 16 weeks after surgery, respectively. Samples were then processed for analysis by light microscopy. Newly formed bone was found around both PLLA and PLLA/PEO implants. PLLA/PEO blends had a porous morphology after immersion in a buffer solution and in vivo implantation. The proportion 50/50 PLLA/PEO blend was adequate to promote this porous morphology, which resulted in gradual bone tissue growth into the implant.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Oral administration with solid dosage forms is a common route in the drug therapy widely used. The drug release by the disintegration process occurs in several gastrointestinal tract (GIT) regions. AC Biosusceptometry (ACB) was originally proposal to characterize the disintegration process of tablets in vitro and in the human stomach, through changes in magnetic signals. The aim of this work was to employ a multisensor ACB system to monitoring magnetic tablets and capsules in the human GIT and to obtain the magnetic images of the disintegration process. The ACB showed accuracy to quantify the gastric residence time, the intestinal transit time and the magnetic images allowed to visualize the disintegration of magnetic formulations in the GIT. The ACB is a non-invasive, radiation free technique, completely safe and harmless to the volunteers and had demonstrated potential to evaluate pharmaceutical dosage forms in the human gastrointestinal tract. © 2005 IEEE.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objectives-The purpose of this study was to evaluate the association between placental volumes, placental vascularity, and hypertensive disorders in pregnancy.Methods A prospective case-control study was conducted between April 2011 and July 2012. Placental volumes and vascularity were evaluated by 3-dimensional sonographic, 3-dimensional power Doppler histographic, and 2-dimensional color Doppler studies. Pregnant women were classified as normotensive or hypertensive and stratified by the nature of their hypertensive disorders. The following variables were evaluated: observed-to-expected placental volume ratio, placental volume-to-estimated fetal weight ratio, placental vascular indices, and pulsatility indices of the right and left uterine and umbilical arteries.Results Sixty-six healthy pregnant women and 62 pregnant women with hypertensive disorders were evaluated (matched by maternal age, gestational age at sonography, and parity). Placental volumes were not reduced in pregnancy in women with hypertensive disorders (P > .05). Conversely, reduced placental vascularization indices (vascularization index and vascularization-flow index) were observed in pregnancies complicated by hypertensive disorders (P < .01; P < .01), especially in patients with superimposed preeclampsia (P = .04; P = .02). A weak correlation was observed between placental volumes, placental vascular indices, and Doppler studies of the uterine and umbilical arteries.Conclusions Pregnancies complicated by hypertensive disorders are associated with reduced placental vascularity but not with reduced placental volumes. These findings are independent of changes in uterine artery Doppler studies. Future studies of the prediction of preeclampsia may focus on placental vascularity in combination with results of Doppler studies of the uterine arteries.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This work assessed the performance of membranes made of natural latex extracted from Hevea brasiliensis prepared with three different methods: polymerized immediately after collection without the use of ammonia (L1); polymerized after preservation in ammonia solution (L2); and polymerized after storage in ammonia, followed by Soxhlet technique for the extraction of substances (L3). Polytetrafluoroethylene (PTFE) membrane was used as control. Two 10-mm diameter bone defects were surgically made in the calvaria of thirty adult male New Zealand rabbits. Defects (total n = 60) were treated with guided bone regeneration (GBR) using L1, L2, L3 or PTFE membranes (n = 15 for each membrane). Ten animals were euthanized after 7, 20 and 60 days postoperatively so that five samples (n = 5) of each treatment were collected at each time, and bone regeneration was assessed microscopically. The microscopic analysis revealed defects filled with blood clot and new bone formation at the margins of the defect in all 7-day samples, while 20-day defects were mainly filled with fibrous connective tissue. After 60 days defects covered with L1 membranes showed a significantly larger bone formation area in comparison to the other groups (P < 0.05, ANOVA, Tukey). Additionally, bone tissue hypersensitization for L1 and PTFE membranes was also investigated in six additional rabbits. The animals were subjected to the same surgical procedure for the confection of one 10-mm diameter bone defect that was treated with L1 (n = 3) or PTFE (n = 3). Fifty-three days later, a second surgery was performed to make a second defect, which was treated with the same type of membrane used in the first surgery. Seven days later, the animals were euthanized and samples analyzed. No differences among L1 and PTFE samples collected from sensitized and non-sensitized animals were found (P > 0.05, Kruskal-Wallis). Therefore, the results demonstrated that latex membranes presented performance comparable to PTFE membranes, and that L1 membranes induced higher bone formation. L1 and PTFE membranes produced no hypersensitization in the bone tissue.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)