21 resultados para Mechanical response


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Literature data are not conclusive as to the influence of neonatal complications in the maturational process of the auditory system observed by auditory brainstem response (ABR) in infants at term and preterm. Objectives Check the real influence of the neonatal complications in infants by the sequential auditory evaluation. Methods Historical cohort study in a tertiary referral center. A total of 114 neonates met inclusion criteria: treatment at the Universal Neonatal Hearing Screening Program of the local hospital; at least one risk indicator for hearing loss; presence in both evaluations (the first one after hospital discharge from the neonatal unit and the second one at 6 months old); all latencies in ABR and transient otoacoustic emissions present in both ears. Results The complications that most influenced the ABR findings were Apgar scores less than 6 at 5 minutes, gestational age, intensive care unit stay, peri-intraventricular hemorrhage, and mechanical ventilation. Conclusion Sequential auditory evaluation is necessary in premature and term newborns with risk indicators for hearing loss to correctly identify injuries in the auditory pathway.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intra-abdominal adhesions constitute a significant clinical and surgical problem that can lead to complications such as pain and bowel occlusion or subocclusion. These adhesions are frustrating and potentially fatal, representing a major postoperative complication in abdominal surgery. It is estimated that 32% of horses undergoing laparotomy will present clinical symptoms due to adhesions, but the true prevalence is not known because a large proportion of animals with postoperative recurrent colics are medically treated or submitted to euthanasia without necropsy. Adhesions are highly cellular, vascularized, dynamic structures that are influenced by complex signaling mechanisms. Understanding their pathogenesis could assist in applying better therapeutic strategies and in developing more effective antiadhesion products. Currently, there are no definitive strategies that prevent adhesion formation, and it is difficult to interpret the results of existing studies due to nonstandardization of an induction model and evaluation of their severity. The best clinical results have been obtained from using minimally traumatic surgical techniques, anti-inflammatory agents, antimicrobials, anticoagulants, and mechanical separation of serosal surfaces by viscous intraperitoneal solutions or physical barriers. This paper aims to review adhesion formation pathogenesis, guide the understanding of major products and drugs used to inhibit adhesion formation, and address their effectiveness in the equine species.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To validate a model for investigating the effects of analgesic drugs on mechanical, thermal and electrical stimulation testing. To investigate repeatability, sensitivity and specificity of nociceptive tests. Randomised experiment with 2 observers in 2 phases. Mechanical (M), thermal (TL) and electrical (E) stimuli were applied to the dorsal metacarpus (M-left and TL-right) and coronary band of the left thoracic limb (E) and a thoracic thermal stimulus (TT) was applied caudal to the withers in 8 horses (405 ± 43 kg). Stimuli intensities were increased until a clear avoidance response was detected without exceeding 20 N (M), 60°C (TL and TT) and 15 V (E). For each set of tests, 3 real stimuli and one sham stimulus were applied (32 per animal) using a blinded, randomised, crossover design repeated after 6 months. A distribution frequency and, for each stimulus, Chi-square and McNemar tests compared both the proportion of positive responses detected by 2 observers and the 2 study phases. The κ coefficients estimated interobserver agreement in determining endpoints. Sensitivity (384 tests) and specificity (128 tests) were evaluated for each nociceptive stimulus to assess the evaluators' accuracy in detecting real and sham stimuli. Nociceptive thresholds were 3.1 ± 2 N (M), 8.1 ± 3.8 V (E), 51.4 ± 5.5°C (TL) and 55.2 ± 5.3°C (TT). The level of agreement after all tests, M, E, TL and TT, was 90, 100, 84, 98 and 75%, respectively. Sensitivity was 89, 100, 89, 98 and 70% and specificity 92, 97, 88, 91 and 94%, respectively. The high interobserver agreement, sensitivity and specificity suggest that M, E and TL tests are valid for pain studies in horses and are suitable tools for investigating antinociceptive effects of analgesics in horses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This research aims to present a new method to get real attenuation of hearing protection devices, with good reproducibility and a small standard deviation, without relying on skills and cooperation individual. Thus the authors performed tests in 10 individuals without protection and after with two kinds of ear protections (ear plug and ear muffs), to get the threshold limit value in each of the 3 stages. For this, the research used an electrophysical exam, normally used in speech therapy, named ASSR (auditory steady-state response). The principle of this exam is put on individual’s head 3 electrodes, to capture electrical signs directly in auditory nerve. In summary, the authors presented the final results. The method proposed by ANSI (American National Standards Institute) indicated an attenuation of 27.6 dB for ear plugs, while the value found in this work was 16 dB; and for ear muffs, the ANSI method indicated 29.8 dB while the value found here was 28.5 dB.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)