46 resultados para Lung volume measurements
Resumo:
The mobility of water in the soil is a difficult process to be quantified. During precipitation, there is a portion of the water that infiltrates, which is very important for recovering the groundwater balance. This work studies the mobility of water in sandy soils with different textures and residual soils through experiments mounted in lysimeters. The lysimeters were mounted on acrylic cylinder with 11.3 cm diameter and 25.0 cm in length. The sand was deposited using the process sand rain. In the tests it was maintained a hydraulic head of two centimeters above the surface with the aid of a Mariotte flask. The portions of water were controlled in the experiments using relations between weight and volume measurements over time. The data were obtained by monitoring the input and output volumes of water through calibrated reservoir and system weight by an electronic balance. The infiltration front was monitored with the aid of a digital camera. The results indicate that the smaller the particle size of the sand, the lower the speed of the saturation front, the higher the retained volume, the smaller the basic rate of infiltration and the lowest speed of percolation. Moreover, the rate of water loss in the evaporation process indicated no significant difference with variation of the particle size of the samples
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
To evaluate the volumetric changes due to polymerization and thermocycling on different resin-composites. Methods: Thirteen A2 Universal Dentin shade resin-composites (n = 10) from eight manufacturers were evaluated (4Seasons, Grandio, Venus, Amelogen Plus, P90, Z350, Esthet-X, Amaris, Vita-l-escence, Natural-Look, Charisma, Z250 and Opallis). The polymerization shrinkage percentage (PS) was calculated using an image measurement device (ACUVOL - Bisco Dental). Equal volumes of material, standardized by a semisphere polyurethane matrix (d = 3mm) were used and, after 5 minutes of relaxation, the baseline volume measurements were obtained with 18 J of energy dose from the LED light-curing unit. Measurements were obtained after 5 minutes and PS values calculated. Specimens were stored in a drydark environment for 24 hours and re-measured. Specimens were then thermocycled in distilled water between 5oC and 55oC for 20,000 cycles, subjected to another volume measurement at 5,000 cycle intervals. Specimens were gently dried prior to each measurement. Results: Repeated measurements were made using ANOVA (α = 0.05) showed that all resin-composite volumes were influenced by the number of cycles. Volumes at 5 minutes post-polymerization (12.47 ± 0.08) were significantly lower than those at baseline (12.80 ± 0.09). Volumes at 24 hours (12.43 ± 0.19) were insignificantly lower than those at 5 minutes postpolymerization. With regards to the impact of thermocycling, all specimens showed statistically significant increases in volume after 5,000 cycles (13.04 ± 0.22). Although statistically different from those after 5,000 cycles, there was no statistically significant difference between volumes measured at 10,000 (12.87±0.21), 15,000 (12.92±0.24), and 20,000 (12.84±0.23) cycles. Conclusion: According to the video-imaging analysis, thermocycling caused a significant expansion in resin-composites tested, the volume increase was not able to...
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Photoacoustics as a tool for the diagnosis of radicular stress: Measurements in eucalyptus seedlings
Resumo:
In reforesting companies (cellulose industry), eucalyptus is usually cultivated in small plastic containers (50 mL). As seedlings remain for about 120 days in these containers-until transplantation-their roots become space restricted, with consequent limitations in water and nutrient absorption. These restrictions may lead to plant stress, decreasing productivity. In this work, we used the photoacoustic technique to evaluate the photosynthetic activity of Eucalyptus grandis, E. urophylla and E. urograndis seedlings subjected to this limited space availability, seeking a correlation with morphological parameters and fluorescence measurements in these seedlings. Photoacoustic, fluorescence, and morphological analysis were conducted every 15 days, from 45 to 120 days after sowing. Fluorescence and photosynthetic rate were evaluated in vivo and in situ, the latter one using the open photoacoustic technique. Data show that root dry matter diminished markedly at 90 and 120 days after sowing; this behavior showed a high correlation with the gas exchange component of the photoacoustic signal, as well as with the fluorescence ratio Fv/Fm. These results indicate that the soil volume of the container becomes insufficient for the roots after 90 days, probably leading to a nutritional deficiency in plants, which explains the decrease observed in the photosynthetic rate of seedlings. (C) 2003 American Institute of Physics.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
In patients with acute respiratory distress syndrome, positive end-expiratory pressure is associated with alveolar recruitment and lung hyperinflation despite the administration of a low tidal volume. The best positive end-expiratory pressure should correspond to the best compromise between recruitment and distension, a condition that coincides with the best respiratory elastance.
Resumo:
Objective: To compare the efficiency of an Aeroneb Pro vibrating plate and an Atomisor MegaHertz ultrasonic nebulizer for providing ceftazidime distal lung deposition.Design: In vitro experiments. One gram of cetazidime was nebulized in respiratory circuits and mass median aerodynamic diameter of particles generated by ultrasonic and vibrating plate nebulizers was compared using a laser velocimeter. In vivo experiments. Lung tissue concentrations and extrapulmonary depositions were measured in ten anesthetized ventilated piglets with healthy lungs that received 1 g of ceftazidime by nebulization with either an ultrasonic (n = 5), or a vibrating plate (n = 5) nebulizer.Setting: A two-bed Experimental Intensive Care Unit of a University School of Medicine.Intervention: Following sacrifice, 5 subpleural specimens were sampled in dependent and nondependent lung regions for measuring ceftazidime lung tissue concentrations by high-performance liquid chromatography.Measurements and results: Mass median aerodynamic diameters generated by both nebulizers were similar with more than 95% of the particles between 0.5 and 5 mu m. Lung tissue concentrations were 553 +/- 123 [95% confidence interval: 514-638] mu g g(-1) using ultrasonic nebulizer, and 452 +/- 172 [95% confidence interval: 376-528] mu g g(-1) using vibrating plate nebulizers (NS). Extrapulmonary depositions were, respectively, of 38 +/- 5% (ultrasonic) and 34 +/- 4% (vibrating plate) (NS).Conclusions: Vibrating plate nebulizer is comparable to ultrasonic nebulizers for ceftazidime nebulization. It may represent a new attractive technology for inhaled antibiotic therapy.
Resumo:
The left ventricular mass (LVM) measurement is of major importance for renal patients, as ventricular hypertrophy is an important prognostic index. The echo-cardiogram of the ventricular mass is larger before than it is after hemodialysis, which can confuse data interpretation. The aim of this work is to study the influence of alterations in fluid volume on the variations in measurements of ventricular mass observed during the course of a hemodialysis. Sixteen patients with chronic renal insufficiency in hemodialysis were evaluated at the Dialysis Unit of the University Hospital-UNESP, Botucatu, São Paulo State. The left ventricular mass was calculated from echocardiograms taken before and after hemodialysis and simultaneous ultra-filtration (12 patients: UF GROUP) and before and after hemodialysis isovolemic phase with sequential ultra-filtration (10 patients: ISO GROUP). Six of these patients were submitted to measurements of left ventricular mass before and after hemodialysis in both isovolemic and simultaneous ultra-filtration procedures. In the UF group, there was significant reduction in the following parameters before and after dialysis: diastolic diameter from 54.0 +/- 6.0 mm to 45.6 +/- 7.6 mm; left ventricular mass from 342 +/- 114 g to 265 +/- 117 g; and its respective index (IMVE) from 214 +/- 68 g/m(2) to 168 +/- 71 g/m(2). The ISO group showed no statistically significant variation. The behavior of the variables of six patients submitted to both observations confirm these results. In conclusion, the variations in echocardiogram measurements of the left ventricular mass relating to hemodialysis appear to be induced by alterations of the volemic condition.
Resumo:
Background and objectives Peritoneal dialysis is still used for AKI in developing countries despite concerns about its limitations. The objective of this study was to explore the role of high-volume peritoneal dialysis in AM patients in relation to metabolic and fluid control, outcome, and risk factors associated with death.Design, setting, participants, & measurements A prospective study was performed on 204 AKI patients who were assigned to high-volume peritoneal dialysis (prescribed Kt/V=0.60/session) by flexible catheter and cycler; 150 patients (80.2%) were included in the final analysis.Results Mean age was 63.8 +/- 15.8 years, 70% of patients were in the intensive care unit, and sepsis was the main etiology of AKI (54.7%). BUN and creatinine levels stabilized after four sessions at around 50 and 4 mg/dl, respectively. Fluid removal and nitrogen balance increased progressively and stabilized around 1200 ml and -1 g/d after four sessions, respectively. Weekly delivered Kt/V was 3.5 +/- 0.68. Regarding AKI outcome, 23% of patients presented renal function recovery, 6.6% of patients remained on dialysis after 30 days, and 57.3% of patients died. Age and sepsis were identified as risk factors for death. In urine output, increase of 1 g in nitrogen balance and increase of 500 ml in ultrafiltration after three sessions were identified as protective factors.Conclusions High-volume peritoneal dialysis is effective for a selected AKI patient group, allowing adequate metabolic and fluid control. Age, sepsis, and urine output as well as nitrogen balance and ultrafiltration after three high-volume peritoneal dialysis sessions were associated significantly with death. Clin J Am Soc Nephrol 7: 887-894, 2012. doi: 10.2215/CJN.11131111
Resumo:
OBJETIVO: Verificar se os testes: Volume Expiratório Forçado no 1º segundo (VEF1), Teste de Caminhada de 6 minutos (TC6) e Teste de Escada (TE) se alteram proporcionalmente ao pulmão funcionante ressecado. MÉTODOS: Foram incluídos pacientes candidatos a toracotomia para ressecção pulmonar. No pré-operatório (pré) e no mínimo três meses após a cirurgia (pós), realizaram espirometria, TC6 e TE. O TE foi realizado em escada com 12,16m de altura. O tempo para subir todos os degraus o mais rápido possível foi chamado tempo de escada (tTE). Os cálculos dos valores dos testes preditos para o pós-operatório (ppo) foram realizados conforme o número de segmentos funcionantes perdidos. Os valores pré, ppo e pós foram comparados entre si para cada teste. Estatística: foi utilizada a análise de variância para medidas repetidas (ANOVA), com significância de 5%. RESULTADOS: Foram estudados 40 pacientes. A ressecção pulmonar variou desde o ganho de dois segmentos funcionantes até a perda de 9. Os valores pré, ppo e pós foram respectivamente: VEF1 -pré = 2,6±0,8L, ppo = 2,3±0,8L, pós = 2,3±0,8L (VEF1pré > VEF1ppo = VEF1pós), TC6-pré = 604±63m, ppo = 529±103m, pós = 599±74m (TC6pré = TC6pós > TC6ppo), tTE-pré = 32,9±7,6s, ppo = 37,8±12,1s, pós = 33,7±8,5s (tTEpré = tTEpós < tTEppo). CONCLUSÃO: Nas ressecções pulmonares, este grupo de pacientes perdeu função pulmonar medida através da espirometria, mas não perdeu a capacidade de exercício, medida através dos testes de escada e caminhada.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Real-time ultrasonography (RTU) was used to measure the longissimus dorsi muscle (LM) volume in vivo and to predict the carcass composition of rabbits. For this, 63 New Zealand White × Californian rabbits with 2093±63 g live weight were used. Animals were scanned between the 6th and 7th lumbar vertebrae using an RTU equipment with a 7.5 MHz probe. Measurements of LM volume were obtianed both in vivo and on carcass. Regression equations were used for the prediction of carcass composition and LM volume using the LM volume measured obtained with RTU (LMVU) as independent variable. Carcass meat, bone and total dissectible fat weights represented 780, 164 and 56 g/kg of the reference carcass weight, respectively. Regression equations showed a strong relationship between LMVU and the correspondent volume in carcass. Furthermore, LMVU was also useful in predicting the amounts of carcass tissues. It is possible to predict LM volume in the carcass using the LM volume measured in vivo by RTU. The amount of carcass tissues can be predicted by the LM volume measured in vivo by RTU.
Resumo:
Studies of cooking-generated NO2 effects are rare in occupational epidemiology. In the present study, we evaluated the lung function of professional cooks exposed to NO2 in hospital kitchens. We performed spirometry in 37 cooks working in four hospital kitchens and estimated the predicted FVC, FEV1 and FEF25-75, based on age, sex, race, weight, and height, according to Knudson standards. NO2 measurements were obtained for 4 consecutive days during 4 different periods at 20-day intervals in each kitchen. Measurements were performed inside and outside the kitchens, simultaneously using Palm diffusion tubes. A time/exposure indicator was defined as representative of the cumulative exposure of each cook. No statistically significant effect of NO2 exposure on FVC was found. Each year of work as a cook corresponded to a decrease in predicted FEV1 of 2.5% (P = 0.046) for the group as a whole. When smoking status and asthma were included in the analysis the effect of time/exposure decreased about 10% and lost statistical significance. on predicted FEF25-75, a decrease of 3.5% (P = 0.035) was observed for the same group and the inclusion of controllers for smoking status and asthma did not affect the effects of time/exposure on pulmonary function parameter. After a 10-year period of work as cooks the participants of the study may present decreases in both predicted FEV1 and FEF25-75 that can reach 20 and 30%, respectively. The present study showed small but statistically significant adverse effects of gas stove exposure on the lung function of professional cooks.