30 resultados para Load cells
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Civil - FEIS
Resumo:
The purpose of this study was to evaluate in vitro the shear bond strenght to bovine dentin, during 24h and 30 days with the following variables: resin cements Enforce and Panavia F; aesthetics restorative materials Art Glass, IPS Empress 2 and Targis, with surface treatment with microetching with aluminium oxide, fluoridric acid and silane. Two hundred eighty eight sound bovine teeth from 3 years old animals constituted the samples after inclusion on polyester resin box. lnstron model 430 Universal Testing Machine, a crosshead speed 0,5 mm/min and load cells of 500 Kg, was used for shear bond strenght testing (MPa). The results were statistically analysed by ANOVA The best result was obtained with /PS Empress 2, microetched with aluminium oxide, fluoridric acid and silane, cemented with Panavia F and stored in distilled water, 3f'C during 30 days
Resumo:
With the passage of time, the variety of companies from each branch has gradually grown throughout the country. As a consequence, the logistics to attend to such demand has grown in the same proportion. One factor to highlight about this rapid growth is the increase of freight vehicles roaming the roads, often carrying loads over the limit established by law. At first it may seem that this would not bring any problem, however, note that an excessive number of overloads ends up deteriorating the asphalt, causing ondulations, potholes and other imperfections on the roads, which can cause accidents. In addition, the money spent for the maintenance of the roads is high. Thinking about it, it was established by law a regulation that restricts the weight limit for these vehicles, through axle weighing, subject to a fine. With this control the road floor is preserved for longer, requiring less maintenance expenses. The weighing stations use load cells to display the inferred weight, these cells use strain gages in its construction. The following work presents a methodology to dimension a binocular load cell, its main elements and its dimensioning. Showing how different materials can affect the dimensioning, so that can work satisfactorily. It also presents an overview of how are the parameters for weighing, and fines
Resumo:
In engineering projects, it’s fundamental to determine the active loads in components in order to guarantee acceptable values of safety and reliability according to project specifications. On the other hand, force measurement methods might be very complex and impracticable in some cases and, so that, load cells with eletric resistance strain gages can be applied as a simple and accurate option to measure the required load. The main purpose of this paper is to present the development of a load cell that measures uniaxial forces using electric resistance strain gages without being influenced by the location of the loading in a cantilever beam. For that, it was taken as basis a secondary purpose which is to present a general study of basic and wide concepts about transducers, load cells and extensometers primarily. Information such as: loading and measurements types, characteristics of the presented devices as well as factors that influence its functioning, the most common kinds of Wheatstone bridge links, the main points of a load cell project, cements used to fix extensometers and, finally, the project itself with the tests of the built transducer are presented. By the end of this paper, all the results are shown and analyzed, concluding about the designed load cell and the work itself
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Patients infected with the human immunodeficiency virus (HIV) are at higher risk of developing Epstein-Barr Virus (EBV)-associated lymphomas. The usefulness of monitoring EBV in peripheral blood mononuclear cells (PBMCs) of patients infected with HIV has not been established. The aim of this study was to evaluate the EBV viral load in PBMCs, the frequency of viral genotypes, and the presence of the 30-bp deletion in the BNLF-1 gene. DNA samples from 156 patients attending the HIV/AIDS Day Clinic at Botucatu School of Medicine, Sao Paulo State University were evaluated. The EBV viral load was detectable by real time PCR in 123/156 (78.8%) cases and was higher in patients not receiving antiretroviral treatment or under therapeutic failure than in patients under successful highly active antiretroviral therapy (HAART) (P=0.0076). Overall, the profile of patients with high EBV viral load included elevated HIV viremia (P=0.0005), longer time of HIV diagnosis (P=0.0026), and increased levels of T CD8 + lymphocytes (P=0.0159). The successful amplification of the EBNA-2 gene by nested-PCR was achieved in 95 of 123 (77.2%) cases, of which 75.8% were EBV-1, 9.5% EBV-2, and 14.7% were co-infected with both EBV-1 and -2. The analysis of the BNLF-1 gene was possible in 99 of 123 (80.5%) cases, of which 50.5% had the 30-bp deletion. EBV-1 was more common than EBV-2, which may reflect the fact that the cohort was predominantly Caucasian and heterosexual. J. Med. Virol. 85:2110-2118, 2013. © 2013 Wiley Periodicals, Inc.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)