40 resultados para LATERAL FORCE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The adhesion force between an atomic force microscope (AFM) tip and sample surfaces, mica and quartz substrates, was measured in air and water. The force curves show that the adhesion has a strong dependence on both the surface roughness and the environmental conditions surrounding the sample. The variability of the adhesion force was examined in a series of measurements taken at the same point, as well as at different places on the sample surface. The adhesion maps obtained from the distribution of the measured forces indicated regions contaminated by either organic compounds or adsorbed water. Using simple mathematical expressions we could quantitatively predict the adhesion force behavior in both air and water. The experimental results are in good agreement with theoretical calculations, where the adhesion forces in air and water were mostly associated with capillary and van der Waals forces, respectively. A small long-range repulsive force is also observed in water due to the overlapping electrical double-layers formed on both the tip and sample surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We imaged pores on the surface of the cell wall of three different industrial strains of Saccharomyces cerevisiae using atomic force microscopy. The pores could be enlarged using 10 mM diamide, an SH residue oxidant that attacks surface proteins. We found that two strains showed signs of oxidative damage via changes in density and diameter of the surface pores. We found that the German strain was resistant to diamide induced oxidative damage, even when the concentration of the oxidant was increased to 50 mM. The normal pore size found on the cell walls of American strains had diameters of about 200nm. Under conditions of oxidative stress the diameters changed to 400nm.This method may prove to be a useful rapid screening process (45-60 min) to determine which strains are oxidative resistant, as well as being able to screen for groups of yeast that are sensitive to oxidative stress. This rapid screening tool may have direct applications in molecular biology (transference of the genes to inside of living cells) and biotechnology (biotransformations reactions to produce chiral synthons in organic chemistry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Engineers often face the challenge of reducing the level of vibrations experienced by a given payload or those transmitted to the support structure to which a vibrating source is attached. In order to increase the range over which vibrations are isolated, soft mounts are often used in practice. The drawback of this approach is the static displacement may be too large for reasons of available space for example. Ideally, a vibration isolator should have a high-static stiffness, to withstand static loads without too large a displacement, and at the same time, a low dynamic stiffness so that the natural frequency of the system is as low as possible which will result in an increased isolation region. These two effects are mutually exclusive in linear isolators but can be overcome if properly configured nonlinear isolators are used. This paper is concerned with the characterisation of such a nonlinear isolator comprising three springs, two of which are configured to reduce the dynamic stiffness of the isolator. The dynamic behaviour of the isolator supporting a lumped mass is investigated using force and displacement transmissibility, which are derived by modelling the dynamic system as a single-degree-of-freedom system. This results in the system dynamics being approximately described by the Duffing equation. For a linear isolator, the dynamics of the system are the same regardless if the source of the excitation is a harmonic force acting on the payload (force transmissibility) or a harmonic motion of the base (displacement transmissibility) on which the payload is mounted. In this paper these two expressions are compared for the nonlinear isolator and it is shown that they differ. A particular feature of the displacement transmissibility is that the response is unbounded at the nonlinear resonance frequency unless the damping in the isolator is greater than some threshold value, which is not the case for force transmissibility. An explanation for this is offered in the paper. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The literature reports that the eccentric muscular action produces greater force and lower myoelectric activity than the concentric muscular action, while the heart rate (HR) responses are bigger during concentric contraction. Objectives: To investigate the maximum average torque (MAT), surface electromyographic (SEMG) and the heart rate (HR) responses during different types of muscular contraction and angular velocities in older men. Methods: Twelve healthy men (61.7 +/- 1.6years) performed concentric (C) and eccentric (E) isokinetic knee extension-flexion at 60 degrees/s and 120 degrees/s. SEMG activity was recorded from vastus lateralis muscle and normalized by Root Mean Square-RMS (mu V) of maximal isometric knee extension at 60 degrees. HR (beats/min) and was recorded at rest and throughout each contraction. The data were analyzed by the Friedman test for repeated measures with post hoc Dunn's test (p<0.05). Results: The median values of MAT (N.m/kg) was smaller and the RMS (mu V) was larger during concentric contraction (C60 degrees/s=2.80 and 0.99; C120 degrees/s=2.46 and 1.0) than eccentric (E60 degrees/s=3.94 and 0.85; E120 degrees/s=4.08 and 0.89), respectively. The HR variation was similar in the four conditions studied. Conclusion: The magnitude of MAT and RMS responses in older men were dependent of the nature of the muscular action and independent of the angular velocity, whereas HR response was not influenced by these factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Police officers are exposed to impact noise coming from firearms, which may cause irreversible injuries to the hearing system.Aim: To evaluate the noise exposure in shooting stands during gunfire exercises, to analyze the acoustic impact of the noise produced by the firearms and to associate it with tonal audiometry results.Study design: Cross-sectional.Materials and methods: To measure noise intensity we used a digital sound level meter, and the acoustic analysis was carried out by means of the oscillations and cochlear response curves provided by the Praat software. 30 police officers were selected (27 males and 3 females).Results: The peak level measured was 113.1 dB(C) from a .40 pistol and 116.8 dB(C) for a .38 revolver. The values obtained for oscillation and Praat was 17.9 +/- 0.3 Barks, corresponding to the rate of 4,120 and 4,580 Hz. Audiometry indicated greater hearing loss at 4,000Hz in 86.7% of the cases.Conclusion: With the acoustic analysis it was possible to show cause and effect between the main areas of energy excitation of the cochlea (Praat cochlear response curve) and the frequencies of low hearing acuity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article analyzes the creation and development of the São Paulo police force during the early years of the republican regime. In a period of political change and turbulence, institutional upheaval (uprising of the Navy and federalist revolution), and social pressure, São Paulo's police force played an important role. As the state sought to organize the public sphere, the police force became a tool in the new government's hands. A more martial set of demands mobilized a large portion of the troops on behalf of the federal government against the Custodio de Mello uprising, and sought to defend São Paulo's borders. Despite official discourse that fomented a militarized response, São Paulo's police force found itself unable to dismiss old personnel and practices and dislodge entrenched interests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tireóide ectópica é qualquer tecido tireoideano localizado fora de sua topografia habitual, podendo apresentar-se na linha mediana do pescoço ou, mais raramente, na região cervical lateral. Algumas teorias tentam explicar a origem do tecido tireoideano ectópico: 1. falha na descida da glândula; 2. seqüestro de nódulos tireoideanos; 3. presença de tecido tireoideano na cápsula de linfonodos cervicais; 4. formação teratomatosa; 5. Secundário a anomalias branquiais. Na abordagem diagnóstica, diversos exames têm sido utilizados, sendo o diagnóstico definitivo algumas vezes fornecido apenas pelo estudo histopatológico. Apesar das controvérsias em relação às abordagens terapêuticas apresentadas na literatura, é necessário um planejamento rigoroso para evitar iatrogenias. Conclui-se que a presença de tecido tireoideano ectópico deve ser lembrada no diagnóstico diferencial de massas cervicais laterais, e sua origem histológica considerada, sendo na maioria das vezes metástase de um carcinoma tireoideano oculto. Os autores relatam um caso de tecido tireoideano ectópico lateral no pescoço, em paciente do sexo feminino com bócio colóide mergulhante. Foram realizadas considerações importantes sobre dismorfogênese tireoideana, métodos diagnósticos e opções de tratamento, com revisão da literatura das últimas cinco décadas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the construction of a homogeneous phantom to be used in simulating the scattering and absorption of X-rays by a standard patient chest and skull when irradiated laterally. This phantom consisted of Incite and aluminium plates with their thickness determined by a tomographic exploratory method applied to the anthropomorphic phantom. Using this phantom, an optimized radiographic technique was established for chest and skull of standard sized patient in lateral view. Images generated with this optimized technique demonstrated improved image quality and reduced radiation doses. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To compare the analgesic effect of uni- and bi-lateral electroacupuncture (EA) in response to thermal and mechanical nociceptive stimuli and to investigate the cardiorespiratory, endocrine, and behavioral changes in dogs submitted to EA.Study design Prospective, randomized cross-over experimental study.Animals Eight adult, clinically healthy, cross-breed dogs, weighing 13 +/- 4 kg.Methods Dogs underwent electrostimulation at false acupoints (T-false); bilateral EA at acupoints, stomach 36, gall bladder 34 and spleen 6 (T-EA/bil); unilateral EA at the same points (T-EA/uni) or were untreated (T-control). All animals received acepromazine (0.05 mg kg(-1)) IV; and heart rate, pulse oximetry, indirect arterial blood pressure, respiratory rate, PECO2, rectal temperature, and plasma cortisol concentration were measured before, during, and after EA. Analgesia was tested using thoracic and abdominal cutaneous thermal and mechanical stimuli, and an interdigital thermal stimulus. Behavior was classified as calm or restless. Analysis of variance for repeated measures followed by Tukey's test was used for analysis of the data.Results There were no cardiorespiratory differences among the treatments. The cutaneous pain threshold was higher after EA, compared with false points. The latency period was shorter and analgesia was more intense in T-EA/bil than T-EA/uni, when both were compared with T-false and T-control. Six out of eight animals treated with EA were calm during treatment, and 5/8 and 4/8 of the T-false and T-control animals, respectively, were restless. Latency to interdigital thermal stimulation increased in T-EA/bil compared with the others. There was no difference in plasma cortisol concentrations among the treatments.Conclusions Bilateral EA produced a shorter latency period, a greater intensity, and longer duration of analgesia than unilateral stimulation, without stimulating a stress response.Clinical relevance Bilateral EA produces a better analgesic effect than unilateral EA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho foi investigar os aspectos morfológicos da bulla tympanica após osteotomia ventral e lateral. Quarenta cães adultos foram distribuídos em dois grupos de 20 animais cada. No grupo A , os animais foram submetidos a osteotomia ventral da bulla tympanica e no grupo B, a osteotomia lateral da bulla tympanica. Cada grupo foi constituído de 2 subgrupos, de acordo com o período de observação: A1 e B1 (6 semanas), A2 e B2 (12 semanas). No exame macroscópico constatou-se que a concavidade de todas as bullae tympanicae operadas era semelhante às normais. Os estudos histológicos mostraram que a regeneração completa da bulla tympanica ocorreu em apenas alguns animais de cada subgrupo. A presença de tecido conjuntivo na área de osteotomia foi verificada na maioria das bullae tympanicae operadas, resultado estatisticamente significante. A análise histológica e a histomorfometria computadorizada não mostraram diferença significante quanto ao estágio de regeneração óssea em todos os subgrupos. Concluiu-se que uma área de ostetomia restrita não causou alterações significantes na conformação da bulla tympanica de cães submetida a osteotomia ventral ou lateral; e que a regeneração total da bulla tympanica geralmente não ocorreu antes de 12 semanas de pós-operatório.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inhibitory serotonergic and cholecystokinergic mechanisms in the lateral parabrachial nucleus and central GABAergic mechanisms are involved in the regulation of water and NaCl intake. In the present study we investigated if the GABA(A) receptors in the lateral parabrachial nucleus are involved in the control of water, NaCl and food intake in rats. Male Holtzman rats with stainless steel cannulas implanted bilaterally into the lateral parabrachial nucleus were used. Bilateral injections of muscimol (0.2 nmol/0.2 mu l) into the lateral parabrachial nucleus strongly increased 0.3 M NaCl (20.3 +/- 7.2 vs. saline: 2.6 +/- 0.9 ml/180 min) without changing water intake induced by the treatment with the diuretic furosemide combined with low dose of the angiotensin converting enzyme inhibitor captopril s.c. In euhydrated and satiated rats, bilateral lateral parabrachial nucleus injections of muscimol (0.2 and 0.5 nmol/0.2 0) induced 0.3 M NaCl intake (12.1 +/- 6.5 and 32.5 +/- 7.3 ml/180 min, respectively, vs. saline: 0.4 +/- 0.2 ml/180 min) and water intake (5.2 +/- 2.0 and 7.6 +/- 2.8 ml/ 180 min, respectively, vs. saline: 0.8 +/- 0.4 ml/180 min), but no food intake (2 +/- 0.4 g/240 min vs. saline: 1 +/- 0.3 g/240 min). Bilateral lateral parabrachial nucleus injections of the GABAA antagonist bicuculline (1.6 nmol/0.2 mu l) abolished the effects of muscimol (0.5 nmol/0.2 mu l) on 0.3 M NaCl and water intake. Muscimol (0.5 nmol/0.2 mu l) into the lateral parabrachial nucleus also induced a slight ingestion of water (4.2 +/- 1.6 ml/240 min vs. saline: 1.1 +/- 0.3 ml/240 min) when only water was available, a long lasting (for at least 2 h) increase on mean arterial pressure (14 +/- 4 mm Hg, vs. saline: -1 +/- 1 mm Hg) and only a tendency to increase urinary volume and Na+ and K+ renal excretion. Therefore the activation of GABAA receptors in the lateral parabrachial nucleus induces strong NaCl intake, a small ingestion of water and pressor responses, without changes on food intake. (c) 2005 Published by Elsevier Ltd on behalf of IBRO.