20 resultados para LARGE-STRAIN DEFORMATION


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Lewis histo-blood group system is characterized by the expression of the Lea and Le(b) antigens in the gastrointestinal tract, whose synthesis results in interactions between alpha 2-L-fucosyltransferase (FUTII) and alpha 3/4-L-fucosyltransferase (FUTIII) enzymes coded by the FUT2 (19q. 13.3) and FUT3 (19p13.3) genes. FUTII and FUTIII fucosylate the type 1 oligosaccharide precursor (Gal beta 1 -> 3NAcGlc beta 1 -> 3-R) at distinct positions to form H type 1 (Fuc alpha 1. 2Gal beta 1. 3NAcGlc beta 1 -> 3-R) and Le(a) (Gal beta 1 -> 3[Fuc alpha 1 -> 4] NAcGlc beta 1 -> 3-R) antigens, respectively. The fucosylation of H type 1 antigens by FUTIII results in the Leb antigen (Fuc alpha 1. 2Gal beta 1. 3[Fuca1. 4] NAcGlc beta 1. 3-R). Thus, the presence of the FUTII and FUTIII enzymes leads to the expression of the Le(a+b+) phenotype, while the presence of only FUTIII allows the expression of the Le(a+b-) phenotype. The absence of the FUTIII enzyme leads to the expression of the Le(a-b-) phenotype, independent of the presence or absence of FUTII. Point mutations in FUT2 and FUT3 genes change the activity of these enzymes, impair the synthesis of Le(a) and Le(b) antigens, and contribute to the variability of Lewis phenotypes in the gastrointestinal tract. Toxoplasma gondii, an apicomplexan parasite that infects a large proportion of the world's population, utilizes the gastrointestinal tract as an infection route and seems to adhere to glycosylated molecules to invade human cells. These apparently independent events may be related. The aim of this study was to test the hypothesis that there is an association between the Lewis histo-blood group system and infection by T. gondii. Two hundred and nine serum samples collected from pregnant women were submitted to screening tests to detect anti-T. gondii antibodies, employing the indirect hemagglutination method. ELISA was utilized to identify IgG class anti-T. gondii antibodies specific for the RH strain. A hundred and ninety-five samples with concordant results for both methods were selected to form two groups: seropositive (G1) and seronegative (G2). The G428A mutation of the FUT2 gene, and T202C and C314T of the FUT3 gene, which allow inference of the gastrointestinal tract Lewis phenotypes, were identified using PCR-RFLP and PCR-SSP methods, respectively. Among the 195 samples selected, 116 (59.5%) were seropositive and 79 (40.5%) were seronegative. In G1, 68 (58.6%) were classified as Le(a+b+), 30 (25.9%) as Le(a+b-), and 18 (15.5%) as Le(a-b-), and in G2, 67 (84.8%) were classified as Le(a+b+), 12 (15.2%) as Le(a+b-), and 0 (0%) as Le(a-b-) (P < 0.0001). The Le(a-b-) phenotype is associated with a high risk of RH strain T. gondii infection when compared with the Le(a+b+) [P = 0.0001; OR = 36,460; 95%CI = 2.152-617,680] and Le(a+b-) phenotypes [P = 0.0118; OR = 15,165; 95%CI = 0.8463-271,710]. The Le(a+b-) phenotype showed a higher risk compared to the Le(a+b+) phenotype [P = 0.0206; OR = 2463; 95%CI = 2463-5214]. The results suggest that the Le(a-b-) phenotype is strongly associated with a greater risk of infection by the RH strain of T. gondii compared to the other phenotypes. It is possible that the absence of fucosylation of the type 1 oligosaccharide precursor as well as the variations in the structures of the Le(a) and Le(b) antigens influence susceptibility to infection by this parasite.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to use the finite element method to evaluate the distribution of stresses and strains on the local bone tissue adjacent to the miniplate used for anchorage of orthodontic forces. Methods: A 3-dimensional model composed of a hemimandible and teeth was constructed using dental computed tomographic images, in which we assembled a miniplate with fixation screws. The uprighting and mesial movements of the mandibular second molar that was anchored with the miniplate were simulated. The miniplate was loaded with horizontal forces of 2, 5, and 15 N. A moment of 11.77 N.mm was also applied. The stress and strain distributions were analyzed, and their correlations with the bone remodeling criteria and miniplate stability were assessed. Results: When orthodontic loads were applied, peak bone strain remained within the range of bone homeostasis (100-1500 mu m strain) with a balance between bone formation and resorption. The maximum deformation was found to be 1035 mu m strain with a force of 5 N. At a force of 15 N, bone resorption was observed in the region of the screws. Conclusions: We observed more stress concentration around the screws than in the cancellous bone. The levels of stress and strain increased when the force was increased but remained within physiologic levels. The anchorage system of miniplate and screws could withstand the orthodontic forces, which did not affect the stability of the miniplate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the deformation suffered by cantilevered implant-supported fixed prostheses frameworks cast in silver-palladium alloy and coated with two occlusal veneering materials: acrylic resin or porcelain. Material and Methods: Two strain gauges were bonded to the inferior surface of the silver-palladium framework and two other were bonded to the occlusal surface of the prosthesis framework covered with ceramic and acrylic resin on each of its two halves. The framework was fixed to a metallic master model and a 35.2 N compression force was applied to the cantilever at 10, 15 and 20 mm from the most distal implant. The measurements of deformation by compression and tension were obtained. The statistical 2-way ANOVA test was used for individual analysis of the experiment variables and the Tukey test was used for the interrelation between all the variables (material and distance of force application). Results: The results showed that both variables had influence on the studied factors (deformation by compression and tension). Conclusion: The ceramic coating provided greater rigidity to the assembly and therefore less distortion compared with the uncoated framework and with the resin-coated framework. The cantilever arm length also influenced the prosthesis rigidity, causing higher deformation the farther the load was applied from the last implant.