98 resultados para Java (Computer program language)--Computer-assisted
Resumo:
OBJETIVO: Quantificar, usando o sistema de imagem digital, medidas palpebrais antes e após a cirurgia de blefaroplastia superior. MÉTODOS: Foram avaliadas 18 pálpebras de 9 pacientes atendidas no HC da FMB - UNESP, com idade entre 40 a 75 anos, do sexo feminino, portadoras de dermatocálase. Foram obtidas fotografias das pacientes antes e após 60 dias da blefaroplastia da pálpebra superior. As imagens foram transferidas para um computador e analisadas pelo programa Scion Image Frame Grabber. Os parâmetros avaliados foram: a altura da fenda palpebral em posição primária do olhar, altura do sulco palpebral superior e o ângulo palpebral lateral antes e depois de 60 dias da realização da cirurgia de blefaroplastia superior. RESULTADOS: Após a cirurgia, houve aumento da altura da fenda palpebral e do sulco palpebral superior. Contudo, o ângulo palpebral lateral não se alterou. CONCLUSÃO: A posição palpebral se altera após a blefaroplastia e o processamento de imagens digitais possibilita quantificar estas alterações, mensurando os resultados obtidos com a cirurgia.
Resumo:
OBJETIVOS: Avaliar o posicionamento palpebral em portadores de cavidade anoftálmica com e sem prótese ocular externa, utilizando o processamento de imagem digital. MÉTODOS: Dezoito pacientes foram avaliados qualitativa e quantitativamente na Faculdade de Medicina de Botucatu - Universidade Estadual Paulista - UNESP, com e sem a prótese externa. Usando imagens obtidas por filmadora e processadas usando o programa Scion Image, mediu-se a altura do sulco palpebral superior, a altura da fenda palpebral e os ângulos palpebrais dos cantos interno e externo. RESULTADOS: Pseudo-estrabismo e sulco palpebral superior profundo foram as alterações mais freqüentes ao exame externo. Houve diferença significativa em todas as variáveis estudadas, com diminuição da altura do sulco palpebral superior, aumento da área da fenda palpebral e aumento dos ângulos palpebrais interno e externo quando o paciente estava usando a prótese externa. CONCLUSÃO: Todos os pacientes avaliados apresentaram algum tipo de anormalidade órbito-palpebral, o que reflete a dificuldade em se proporcionar ao portador de cavidade anoftálmica um aspecto idêntico ao que existe na órbita normal. O processamento de imagens digitais permitiu avaliação objetiva das dimensões óculo-palpebrais, o que poderá contribuir nas avaliações seqüenciais dos portadores de cavidade anoftálmica.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Background. Intravenous injection of contrast material is routinely performed in order to differentiate nonaerated lung parenchyma from pleural effusion in critically ill patients undergoing thoracic computed tomography (CT). The aim of the present study was to evaluate the effects of contrast material on CT measurement of lung volumes in 14 patients with acute lung injury. Method. A spiral thoracic CT scan, consisting of contiguous axial sections of 10 mm thickness, was performed from the apex to the diaphragm at end-expiration both before and 30 s (group 1; n=7) or 15 min (group 2; n=7) after injection of 80 ml contrast material. Volumes of gas and tissue, and volumic distribution of CT attenuations were measured before and after injection using specially designed software (Lungview®; Institut National des Télécommunications, Evry, France). The maximal artifactual increase in lung tissue resulting from a hypothetical leakage within the lung of the 80 ml contrast material was calculated. Results. Injection of contrast material significantly increased the apparent volume of lung tissue by 83 ± 57 ml in group 1 and 102 ± 80 ml in group 2, whereas the corresponding maximal artifactual increases in lung tissue were 42 ± 52 ml and 31 ± 18 ml. Conclusion. Because systematic injection of contrast material increases the amount of extravascular lung water in patients with acute lung injury, it seems prudent to avoid this procedure in critically ill patients undergoing a thoracic CT scan and to reserve its use for specific indications.
Resumo:
Postbloom fruit drop (PFD) of citrus, caused by Colletotrichum acutatum, infects petals of citrus flowers and produces orange-brown lesions that induce the abscission of young fruitlets and the retention of calyces. Proper timing of fungicide applications is essential for good disease control. Different systems for timing of fungicide applications for control of PFD in a major citrus-growing region in southern São Paulo state in Brazil were evaluated from 1999 to 2002. The following programs were compared to an unsprayed control using counts of diseased flowers, persistent calyces, or fruit: (i) a phenology-based program currently recommended in Brazil with one application at early and another at peak bloom; (ii) the Florida PFD model; (iii) the postbloom fruit drop-fungicide application decision system (PFD-FAD), a new computer-assisted decision method; and (iv) grower's choice. In 1999, no disease developed, sprays applied with the phenology-based program had no effect, and the Florida PFD model saved two sprays compared with the phenology-based program. In 2000, PFD was moderate and the phenology-based and growers' choice treatments had a significantly lower number of persistent calyces and higher fruit numbers than the control, but no differences were found between those treatments and the PFD model. In 2001, PFD was severe with considerable yield loss. The PFD model, the phenology-based program, and the grower's choice reduced flower blight and the number of persistent calyces, and improved fruit yields with two to three applications, but the PFD-FAD achieved comparable yields with only one spray. In 2002, the disease was mild, with no yield loss, and the Florida PFD model and the PFD-FAD saved one spray compared with the other systems. The PFD model and the PFD-FAD were equally effective for timing fungicide applications to control PFD in Brazil. Scouting of trees is simpler with PFD-FAD; therefore, this system is recommended and should eliminate unnecessary sprays and reduce costs for growers.
Resumo:
This article introduces a new method for 3-dimensional dental cast analysis, by using a mechanical 3-dimensional digitizer, MicroScribe 3DX (Immersion, San Jose, Calif), and TIGARO software (not yet released, but available from the author at hayasaki@dent.kyushu-u.ac.jp). By digitizing points on the model, multiple measurements can be made, including tooth dimensions; arch length, width, and perimeter; curve of Spee; overjet and overbite; and anteroposterior discrepancy. The bias of the system can be evaluated by comparing the distance between 2 points as determined by the new system and as measured with digital calipers. Fifteen pairs of models were measured digitally and manually, and the bias was evaluated by comparing the variances of both methods and checking for the type of error obtained by each method. No systematic errors were found. The results showed that the method is accurate, and it can be applied to both clinical practice and research. Copyright © 2005 by the American Association of Orthodontists.
Resumo:
Purpose: Spontaneous eye blink activity in the primary eye position and its relationship to age and gender were assessed using digital image processing techniques to quantify blink opening and closing time. Methods: One hundred-and-eighty healthy volunteers (90 males and 90 females), divided into the age groups 0-3, 4-12, 13-20, 21-40, 41-60 and ≥60 years old, were evaluated prospectively. They were videotaped digitally in a standard setting and the images were transferred to a personal computer (Macintosh 400) and processed with the iMovie software. Blink opening and closing time were measured at 30 frames/second. The data were then subjected to statistical analysis. Results: The closing time was significantly longer than the opening time for all ages and both genders. Elderly individuals (≥41 years old) and women had significantly longer closing times. Conclusion: Image processing techniques made possible the observation of differences in spontaneous eye blink opening and closing time in relation to age and gender. Copyright © 2005 Taylor & Francis LLC.
Resumo:
Purpose: To determine palpebral dimensions and development in Brazilian children using digital images. Methods: An observational study was performed measuring eyelid angles, palpebral fissure area and interpupillary distance in 220 children aged from 4 to 72 months. Digital images were obtained with a Sony Lithium movie camera (Sony DCR-TRV110, Brazil) in frontal view from awake children in primary ocular position; the object of observation was located at pupil height. The images were saved to tape, transferred to a Macintosh G4 (Apple Computer Inc., USA) computer and processed using NIH 1.58 software (NTIS, 5285 Port Royal Rd., Springfield, VA 22161, USA). Data were submitted to statistical analysis. Results: All parameters studied increased with age. The outer palpebral angle was greater than the inner, and palpebral fissure and angles showed greater changes between 4 and 5 months old and at around 24 to 36 months. Conclusion: There are significant variations in palpebral dimensions in children under 72 months old, especially around 24 to 36 months. Copyright © 2006 Informa Healthcare.
Resumo:
Purpose: This study evaluated the influence of surface abrasion of transfer copings to obtain a precise master cast for a partially edentulous restoration with different inclinations. Materials and Methods: Replicas (N = 30) of a metal matrix (control group) containing two implants at 90° and 65° in relation to the benchtop were obtained using a polyether impression material and three impression techniques: square impression copings splint with dental floss and autopolymerizing acrylic resin (TRS), square impression copings abraded with aluminum oxide (TA), and square impression copings abraded with aluminum oxide and adhesive-coated (TAA). The replicas obtained in type V stone were digitalized, and the images were exported to AutoCAD software to perform the readings of possible degree alterations in implant inclinations. The results were submitted to analysis of variance (ANOVA) and Tukey test (α < 0.05). Results: Comparing the techniques with regard to the 90° implant inclination, no statistical difference was observed between the three techniques and the control group. Analyzing the three techniques with regard to the 65° implant inclination, no significant difference was seen between technique TA and the control group. Conclusions: Technique TA presented more accurate master casts than TRS and TAA techniques. The angulated implant (65°) tended to generate more imprecise master casts than implants perpendicular to the surface. © 2008 by The American College of Prosthodontists.
Resumo:
The aim of this study was to evaluate whether digitized images obtained from occlusal radiographs taken with low or over dose of radiation could be improved with the aid of computer software for digital treatment. Thirteen occlusal radiographs of a dry skull were taken employing 13 different exposure times. The radiographs were digitized and then manipulated with the program for image editing. 143 evaluations were performed by specialists in dental radiology who classified radiographs as appropriate or not appropriate for interpretation. Test Z was used for statistical analysis of the data and the results showed that it is possible to manipulate digitized radiographic images taken with 75% of the ideal exposure time and to make them suitable for interpretation and diagnosis. Conversely, it was concluded that the over exposed images, 57.50% above the standard exposure time, were inadequate.
Resumo:
Purpose: To analyze the components of the acoustic signal of swallowing using a specific software. Methods: Fourteen healthy subjects ranging in age from 20 to 50 years (mean age 31±10 years), were evaluated. Data collection consisted on the simultaneous capture of the swallowing audio with a microphone and of the swallowing videofluoroscopic image. The bursts of the swallowing acoustic signal were identified and their duration and the interval between them were later analyzed using a specific software, which allowed the simultaneous analyses between the acoustic wave and the videofluoroscopic image. Results: Three burst components were identified in most of the swallows evaluated. The first burst presented mean time of 87.3 milliseconds (ms) for water and 78.2 for the substance. The second burst presented mean time of 112.9 ms for water and 85.5 for the pasty substance. The mean interval between first and second burst was 82.1 ms for water and 95.3 ms for the pasty consistency, and between second and third burst was 339.8 ms for water and 322.0 ms for the pasty consistency. Conclusion: The software allowed the visualization of three bursts during the swallowing of healthy individuals, and showed that the swallowing signal in normal subjects is highly variable.
Resumo:
Pós-graduação em Estudos Linguísticos - IBILCE
Resumo:
Pós-graduação em Medicina Veterinária - FMVZ
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)