65 resultados para Indoor air pollution Measurement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Dentre os efeitos da poluição ambiental na saúde da criança, destaca-se o aumento de internações por pneumonias. O objetivo do estudo foi estimar a associação dessas internações com o aumento dos poluentes atmosféricos. MÉTODOS: Trata-se de estudo ecológico de séries temporais, realizado na cidade de São José dos Campos, SP, nos anos de 2000 e 2001. Foram utilizados dados diários sobre o número de internações por pneumonia, dados diários de poluentes (SO2, O3 e PM10) e de temperatura e umidade do clima. Foram estimadas as correlações entre as variáveis de interesse pelo coeficiente de Pearson. Para estimar a associação entre as internações por pneumonia e a poluição atmosférica, utilizaram-se modelos aditivos generalizados de regressão de Poisson. Foram estimados os acréscimos das internações por pneumonia para o intervalo interquartil para cada um dos poluentes estudados, com um intervalo de confiança de 95% RESULTADOS: Os três poluentes apresentaram efeitos defasados nas internações por pneumonia, iniciada três a quatro dias após a exposição e decaindo rapidamente. Na estimativa de efeito acumulado de oito dias observou-se ao longo desse período que para aumentos de 24,7 µg/m³ na concentração média de PM10 houve um acréscimo de 9,8% nas internações. CONCLUSÕES: O estudo confirma que o potencial deletério dos poluentes do ar sobre a saúde pode ser detectado, também, em cidades de médio porte. A magnitude do efeito foi semelhante ao observado na cidade de São Paulo. Além disso, mostra a elevada susceptibilidade das crianças aos efeitos adversos advindos da exposição aos contaminantes atmosféricos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Air conditioning-induced rhinitis in allergic individuals is a common epidemiologic finding, but its physiopathology,is still controversial. The aim of this study was to describe and compare the effects of experimental air conditioning temperature changes on the nasal mucosa of individuals with persistent allergic rhinitis compared with a control group.Methods: A case-control challenge study was performed in a laboratory of thermal comfort with experimental twin challenge chambers set at a 12 C difference in temperature. A group of 32 patients with persistent allergic rhinitis and a group of 16 control subjects were exposed for 30 minutes, 3 times alternately in each chamber. Nasal symptom scores were recorded and nasal samples collected before, immediately after, and 24 and 48 hours after the challenge.Results: the rhinitis group showed a higher symptom score, epithelial shedding, percentage of eosinophils, total inflammatory cells, leukotriene C-4, eosinophil cationic protein, albumin, and tryptase levels compared with controls. There was also a significant increase in symptom score, total cells recovered, percentage of eosinophils, epithelial shedding, albumin, myeloperoxidase, and soluble intercellular adhesion molecule 1 in both groups compared with baseline levels.Conclusion: Sudden temperature changes led to a more pronounced inflammatory nasal response in the rhinitis group with the recruitment and activation of eosinophils.Clinical implications: Persistent allergic rhinitis is a risk factor for developing sudden temperature change-related rhinitis even in the absence of allergen exposure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The role of air pollution as a health risk factor is of special interest. Numerous toxic pollutants, such as nickel, are being released to the environment as a result of combustion of fossil fuels, crude oil, and coal. Nickel in the atmosphere can be combined with other environmental pollutants, producing various nickel compounds, which have varying animal toxicity. A rat biossay validated for the identification of toxic effects of nickel revealed increased serum activities of total lactate dehydrogenase (LDH) and alanine transaminase (ALT) in rats that received intratracheal injection of Ni2+ in .09% saline solution of NiCl2. The total LDH activity was also increased in the heart, and the isoenzyme pattern showed the LDH1/LDH2 ratio elevated to greater than 1. We conclude that intratracheal administration of nickel induced cardiac and hepatic damage. The development of cardiac and hepatic damage and of increased enzymes' activities was only demonstrated when nickel had accumulated in these tissues, indicating that nickel depot is essential to its toxicity. Intratracheal administration of NiCl2 induced changes in LDH and ALT activities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microbial contamination of an enclosed area may come from outside or be generated within the area itself. In the study described here, bioaerosol levels in hospital air were quantified and related to those found in the air outside, taking into account some of the environmental variables that affect air quality, such as the number of occupants of a room and the type of ventilation. Airborne bacteria were collected for five minute by blowing air at 500 L min -1 in high speed jets on to the surface on plates culture in a single-stage bioaerosol impactor. The mean viable count of bacteria in the air outside in the hospital, São Paulo State, was 77 ± 4 CFU m -3, while in the air inside the hospital it was 302 ± 260 CFU m-3. The operating theatre was the only space sampled with a controlled environment and, after orthopedic surgery, it had the highest bioaerosol count recorded (867 ± 482 CFU m-3). In the enclosed environments, nine bacterial species were identified. Despite the difficulty in establishing precise numbers of bacteria in the bioaerosols in hospital environments, the values obtained demonstrate a need to instigate suitable programs to keep the microbial density low in these environments, and eliminate microorganisms presenting a significant risk to their occupants. It is also recommended that such programs include the monitoring of hospital air, with the aim of defining standards for acceptable numbers of bacteria in the bioaerosol.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Generally, mining causes significant impact over the environment, since this activity often involves suppression of vegetation, soil exposure and erosion resulting in important changes in the quantity and quality of surface and ground-waters and in air pollution, among other negative effects. The prevention and mitigation of these impacts in the State of Sao Paulo are made through the environmental licensing. Another way of environmental management includes programs like mining and environmental zoning and regional mining director plans. But there is clear dissociation between the actions effectively taken and those recommended in the projects, limiting the recovery of degraded areas to measures that only attenuate the visual impact. this paper presents considerations on the subject and challenges of the industry to adapt to the Federal Constitution and the National Policy on Environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Brazil has an important role in the biomass burning, with the detection of approximately 100,000 burning spots in a single year (2007). Most of these spots occur in the southern part of the Amazon basin during the dry season (from August to november) and these emissions reach the southeast of the country, a highly populated region and with serious urban air pollution problems. With the growing demand on biofuels, sugarcane is considerably expanding in the state of São Paulo, being a strong contributor to the bad air quality in this region. In the state of São Paulo, the main land use are pasture and sugarcane crop, that covers around 50% and 10% of the total area, respectively. Despite the aerosol from sugarcane burning having reduced atmospheric residence time, from a few days to some weeks, they might get together with those aerosol which spread over long distances (hundreds to thousands of kilometers). In the period of June through February 2010 a LIDAR observation campaign was carried in the state of São Paulo, Brazil, in order to observe and characterize optically the aerosols from two distinct sources, namely, sugar cane biomass burning and industrial emissions. For this purpose 2 LIDAR systems were available, one mobile and the other placed in a laboratory, both working in the visible (532 nm) and additionally the mobile system had a Raman channel available (607 nm). Also this campaign counted with a SODAR, a meteorological RADAR specially set up to detect aerosol echoes and gas-particle analyzers. To guarantee a good regional coverage 4 distinct sites were available to deploy the instruments, 2 in the near field of biomass burning activities (Rio Claro and Bauru), one for industrial emissions (Cubatão) and others from urban sources (São Paulo). The whole campaign provide the equivalent of 30 days of measurements which allowed us to get aerosol optical properties such as backscattering/extinction coefficients, scatter and LIDAR ratios, those were used to correlate with air quality and meteorological indicators and quantities. In this paper we should focus on the preliminary results of the Raman LIDAR system and its derived aerosol optical quantities. © 2010 Copyright SPIE - The International Society for Optical Engineering.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Taking into account that paracoccidioidomycosis infection occurs by inhalation of the asexual conidia produced by Paracoccidioides spp. in its saprobic phase, this work presents the collection of aerosol samples as an option for environmental detection of this pathogen, by positioning a cyclonic air sampler at the entrance of armadillo burrows. Methods included direct culture, extinction technique culture and Nested PCR of the rRNA coding sequence, comprising the ITS1-5.8S-ITS2 region. In addition, we evaluated one armadillo (Dasypus novemcinctus) as a positive control for the studied area. Although the pathogen could not be isolated by the culturing strategies, the aerosol sampling associated with molecular detection through Nested PCR proved the best method for discovering Paracoccidioides spp. in the environment. Most of the ITS sequences obtained in this investigation proved to be highly similar with the homologous sequences of Paracoccidioides lutzii from the GenBank database, suggesting that this Paracoccidioides species may not be exclusive to mid-western Brazil as proposed so far. © 2013 ISHAM.