92 resultados para High frequency data
Resumo:
We have studied the effects of niobium beam filtration on absorbed doses, on image density and contrast, and on photon spectra with conventional and high-frequency dental x-ray generators. Added niobium reduced entry and superficial absorbed doses in periapical radiography by 9% to 40% with film and digital image receptors, decreased the radiation necessary to produce a given image density on E-speed film and reduced image contrast on D- and E-speed films. As shown by increased half-value layers for aluminum, titanium, and copper and by pulse-height analyses of beam spectra, niobium increased average beam energy by 6% to 19%. Despite the benefits of adding niobium on patient dose reduction and on narrowing the beams' energy spectra, the beam can be overhardened. Adding niobium, therefore, strikes the best balance between radiation dose reduction and beam attenuation, with its risks of increased exposure times, motion blur, and diminished image contrast, when it is used at modest thicknesses (30 μm) and at lower kVp (70) settings. © 1995 Mosby-Year Book, Inc.
Resumo:
This work proposes a new isolated high power factor 12kW power supply based on an 18-pulse transformer arrangement. Three full-bridge converters are used for isolation and to balance the DC-link currents, without current sensing or a current controller. The topology provides a regulated DC output with a very simple control strategy. Simulation and experimental results are presented in this paper.
Resumo:
The aim of this paper is to present a simple method for determining the high frequency parameters of a three-phase induction motor to be used in studies involving variable speed drives with PWM three-phase inverters, in which it is necessary to check the effects caused to the motor by the electromagnetic interference, (EMI) in the differential mode, as well as in the common mode. The motor parameters determination is generally performed in adequate laboratories using accurate instruments, such as very expensive RLC bridges. The method proposed here consists in the identification of the motor equivalent electrical circuit parameters in rated frequency and in high frequency through characteristic tests in the laboratory, together with the use of characteristic equations and curves, shown in the references to be mentioned for determining the motor high frequency parasite capacitances and also through system simulations using dedicated software, like Pspice, determining the characteristic waveforms involved in the differential and common mode phenomena, comparing and validating the procedure through published papers [01].
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
High-frequency ultrasound is a non-invasive tool used in skin ageing research to assess dermis thickness and echogenicity. This study evaluated the reliability of a range of high-frequency ultrasound parameters and tested their correlation with age and a validated clinical scale for the assessment of forearm skin photoageing; the difference between two body sites according to environmental exposition patterns was also investigated. Twenty-three volunteers aged 28-82 years were divided into three groups according to forearm photoageing degree. A 20 MHz ultrasound unit was used to obtain cross-sectional images of the skin by two trained investigators on two different sites: the dorsal forearm (chronically photoexposed skin) and the proximal medial arm (non-photoexposed skin). Several echogenicity parameters were studied for each skin compartment: total dermis, upper dermis and lower dermis, and the ratio between upper and lower dermis. The intraclass correlation coefficient (for complete agreement) between investigators was higher for upper and total dermis echogenicity measures compared with the lower dermis. At the non-photoexposed site, the upper and lower dermis parameter ratio was better correlated with age. At the photoexposed area, total dermis parameters demonstrated higher correlations with clinical score. The authors discuss the choice of parameters for forearm photoageing assessment using high-frequency ultrasound.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The objective of this paper is to verify and analyze the existence in Brazil of stylized facts observed in financial time series: volatility clustering, probability distributions with fat tails, the presence of long run memory in absolute return time series, absence of linear return autocorrelation, gain/loss asymmetry, aggregative gaussianity, slow absolute return autocorrelation decay, trading volume/volatility correlation and leverage effect. We analyzed intraday prices for 10 stocks traded at the BM&FBovespa, responsible for 52.1% of the Ibovespa portfolio on Sept. 01, 2009. The data analysis confirms the stylized facts, whose behavior is consistent with what is observed in international markets.
Resumo:
To ensure high accuracy results from GPS relative positioning, the multipath effects have to be mitigated. Although the careful selection of antenna site and the use of especial antennas and receivers can minimize multipath, it cannot always be eliminated and frequently the residual multipath disturbance remains as the major error in GPS results. The high-frequency multipath from large delays can be attenuated by double difference (DD) denoising methods. But the low-frequency multipath from short delays is very difficult to be reduced or modeled. In this paper, it is proposed a method based on wavelet regression (WR), which can effectively detect and reduce the low-frequency multipath. The wavelet technique is firstly applied to decompose the DD residuals into the low-frequency bias and high-frequency noise components. The extracted bias components by WR are then directly applied to the DD observations to correct them from the trend. The remaining terms, largely characterized by the high-frequency measurement noise, are expected to give the best linear unbiased solutions from a least-squares (LS) adjustment. An experiment was carried out using objects placed close to the receiver antenna to cause, mainly, low-frequency multipath. The data were collected for two days to verify the multipath repeatability. The ground truth coordinates were computed with data collected in the absence of the reflector objects. The coordinates and ambiguity solution were compared with and without the multipath mitigation using WR. After mitigating the multipath, ambiguity resolution became more reliable and the coordinates were more accurate.
Resumo:
A previous work showed that viscosity values measured high frequency by ultrasound agreed with the values at low frequency by the rotational viscometer when conditions are met, such as relatively low frequency viscosity. However, these conditions strongly reduce the range of the measurement cell. In order to obtain a measurement range and sensitivity high frequency must used, but it causes a frequency-dependent decrease on the viscosity values. This work introduces a new simple in order to represent this frequency-dependent behavior.model is based on the Maxwell model for viscoelastic , but using a variable parameter. This parameter has physical meaning because it represents the linear behavior the apparent elasticity measured along with the viscosity by .Automotive oils SAE 90 and SAE 250 at 22.5±0.5oC viscosities at low frequency of 0.6 and 6.7 Pa.s, respectively,tested in the range of 1-5 MHz. The model was used in to fit the obtained data using an algorithm of non-linear in Matlab. By including the viscosity at low frequency an unknown fitting parameter, it is possible to extrapolate its . Relative deviations between the values measured by the and extrapolated using the model for the SAE 90 and SAE 250 oils were 5.0% and 15.7%, respectively.©2008 IEEE.
Resumo:
Despite its high incidence, patellofemoral pain etiology remains unclear. No prior study has compared surface electromyography frequency domain parameters and surface electromyography time domain variables, which have been used as a classic analysis of patellofemoral pain. Thirty one women with patellofemoral pain and twenty eight pain-free women were recruited. Each participant was asked to descend a seven step staircase and data from five successful trials were collected. During the task, the vastus medialis and vastus lateralis muscle activities were monitored by surface electromyography. The data were processed and analyzed in four variables of the frequency domain (median frequency, low, medium and high frequency bands) and three time domain variables (Automatic, Cross-correlation and Visual Onset between the vastus medialis and vastus lateralis muscles). Reliability, Receiver Operating Characteristic curves and regression models were performed. The medium frequency band was the most reliable variable and different between the groups for both muscles, also demonstrated the best values of sensitivity and sensibility, 72% and 69% for the vastus medialis and 68% and 62% for the vastus lateralis, respectively. The frequency variables predicted the pain of individuals with patellofemoral pain, 26% for the vastus medialis and 20% for the vastus lateralis, being better than the time variables, which achieved only 7%. The frequency domain parameters presented greater reliability, diagnostic accuracy and capacity to predict pain than the time domain variables during stair descent and might be a useful tool to diagnose individuals with patellofemoral pain.
Resumo:
Com o objetivo de avaliar a importância da eletrocardiografia de alta resolução no diagnóstico da cardiomiopatia arritmogênica do ventrículo direito do Boxer, 20 cães sem evidências de doença cardíaca estrutural à avaliação ecodopplercardiográfica foram agrupados de acordo com a frequência de arritmias ventriculares, avaliadas pela eletrocardiografia ambulatorial de 24 horas, e submetidos ao exame eletrocardiográfico de alta resolução. Duração do complexo QRS filtrado, duração dos sinais de baixa amplitude (menor que 40µV) dos últimos 40 milissegundos do complexo QRS e raiz quadrada média da voltagem ao quadrado dos últimos 40 milissegundos do complexo QRS (RMS40) foram as variáveis avaliadas. Não foram observadas diferenças significativas entre os grupos em relação às variáveis estudadas. Sendo assim, os resultados do presente estudo sugerem que a eletrocardiografia de alta resolução não é uma ferramenta útil no auxílio diagnóstico da cardiomiopatia arritmogênica do ventrículo direito dos cães da raça Boxer que não apresentam alterações miocárdicas evidentes ou disfunção sistólica.
Resumo:
In the absence of the selective availability, which was turned off on May 1, 2000, the ionosphere can be the largest source of error in GPS positioning and navigation. Its effects on GPS observable cause a code delays and phase advances. The magnitude of this error is affected by the local time of the day, season, solar cycle, geographical location of the receiver and Earth's magnetic field. As it is well known, the ionosphere is the main drawback for high accuracy positioning, when using single frequency receivers, either for point positioning or relative positioning of medium and long baselines. The ionosphere effects were investigated in the determination of point positioning and relative positioning using single frequency data. A model represented by a Fourier series type was implemented and the parameters were estimated from data collected at the active stations of RBMC (Brazilian Network for Continuous Monitoring of GPS satellites). The data input were the pseudorange observables filtered by the carrier phase. Quality control was implemented in order to analyse the adjustment and to validate the significance of the estimated parameters. Experiments were carried out in the equatorial region, using data collected from dual frequency receivers. In order to validate the model, the estimated values were compared with ground truth. For point and relative positioning of baselines of approximately 100 km, the values of the discrepancies indicated an error reduction better than 80% and 50% respectively, compared to the processing without the ionospheric model. These results give an indication that more research has to be done in order to provide support to the L1 GPS users in the Equatorial region.
Resumo:
When GNSS receivers capable of collecting dual-frequency data are available, it is possible to eliminate the first-order ionospheric effect in the data processing through the ionosphere-free linear combination. However, the second- and third-order ionospheric effects still remain. The first-, second- and third-order ionospheric effects are directly proportional to the total electron content (TEC), although the second- and third-order effects are influenced, respectively, by the geomagnetic field and the maximum electron density. In recent years, the international scientific community has given more attention to these kinds of effects and some works have shown that for high precision GNSS positioning these effects have to be taken into consideration. We present a software tool called RINEX_HO that was developed to correct GPS observables for second- and third-order ionosphere effects. RINEX_HO requires as input a RINEX observation file, then computes the second- and third-order ionospheric effects, and applies the corrections to the original GPS observables, creating a corrected RINEX file. The mathematical models implemented to compute these effects are presented, as well as the transformations involving the earth's magnetic field. The use of TEC from global ionospheric maps and TEC calculated from raw pseudorange measurements or pseudoranges smoothed by phase is also investigated.
Resumo:
INTRODUÇÃO: Os níveis de exigência biomecânica devidos ao alto grau de dificuldade na realização de gestos fazem da ginástica artística (GA) uma modalidade com elevado risco de lesões. Assim, é necessário que os aspectos a elas relacionados sejam controlados. OBJETIVO: Analisar a ocorrência de lesões na Ginástica Artística, associando-as a fatores de risco específicos da modalidade e do atleta, a partir de inquérito de morbidade referida. MÉTODOS: Foram entrevistados 54 ginastas, recrutados ao acaso, classificados segundo o nível competitivo em duas categorias: regional e nacional. Utilizou-se o inquérito de morbidade referida (IMR) com a finalidade de reunir dados sobre a natureza da lesão, região corporal e aparelho ginástico. Os dados foram organizados e apresentados sob a forma de distribuição de freqüências e as variáveis, analisadas segundo nível de associação a partir do teste de Goodman para contrastes entre populações multinomiais, considerando significante o valor P < 0,05. RESULTADOS: Presença de lesão durante a temporada foi relatada por 39 (71,70%) atletas, sendo 22 (56,41%) mulheres e 17 (43,59%) homens. Nas categorias regional masculino e feminino e nacional feminino, a maior ocorrência de lesões foi de origem articular, correspondendo a 55,56%, 50% e 45,45% do total, respectivamente. Para o sexo feminino nacional, os membros inferiores foram os mais referidos (68,18%) e, em ambas as categorias, as lesões ocorreram nos aparelhos de saltos (79,41%), enquanto que no sexo masculino nacional o maior número de agravos foi verificado nos aparelhos de apoio e suspensão (72%). CONCLUSÕES: Há elevada freqüência de lesões, acometendo principalmente articulações e membros inferiores, sendo os aparelhos de saltos os mais referidos quanto à ocorrência de acometimentos. Foi observado também que, quanto maiores as exigências de desempenho técnico, maior a freqüência de lesões.